Question 710
At Brookside Manufacturing, the plant operations team is planning an industrial Ethernet modernization under a requirement for planned downtime and resilient cabling. Following a proposed correction, the change manager requires evidence for this original fault: A VoIP call fails intermittently but captures were taken at different times with no synchronized event timeline. Which observation BEST demonstrates that the fix worked?
Explanation
Correct Answer
The reconstructed timeline identifies where RTP or signaling packets first diverge from the expected path. This observation verifies the specific reported problem, A VoIP call fails intermittently but captures were taken at different times with no synchronized event timeline. The intended correction was: Correlate switch packet captures with common time references and endpoint or FortiGate logs. It provides a directly testable outcome for the Brookside Manufacturing environment rather than treating a completed change ticket as proof.
Incorrect Answers
The captured exchange shows whether controller discovery or management packets traverse the intended link. For Brookside Manufacturing, that measurement would support a separate technical case: A FortiLink outage is diagnosed using packets captured on an unrelated user-data VLAN rather than the management link. Its corresponding remedy is: Select the correct FortiLink interface and applicable discovery or control traffic for targeted observation. The reported Brookside Manufacturing condition is A VoIP call fails intermittently but captures were taken at different times with no synchronized event timeline. So the required outcome is: The reconstructed timeline identifies where RTP or signaling packets first diverge from the expected path.
The capture shows the actual transmitted VLAN tags and identifies the mismatched trunk behavior. For Brookside Manufacturing, that measurement would support a separate technical case: A VLAN-tag problem is suspected but a host-side capture hides or offloads 802.1Q tags before the analyst can inspect them. Its corresponding remedy is: Choose a suitable switch-side capture location and interface that preserves the required tag information. The reported Brookside Manufacturing condition is A VoIP call fails intermittently but captures were taken at different times with no synchronized event timeline. So the required outcome is: The reconstructed timeline identifies where RTP or signaling packets first diverge from the expected path.
The analyzer receives the expected test frames from the intended source interface in the specified direction. For Brookside Manufacturing, that measurement would support a separate technical case: A SPAN or mirror session sends traffic to the wrong monitor port and the analyst concludes that packets are absent. Its corresponding remedy is: Validate the supported source, direction and destination of the capture or mirror configuration. The reported Brookside Manufacturing condition is A VoIP call fails intermittently but captures were taken at different times with no synchronized event timeline. So the required outcome is: The reconstructed timeline identifies where RTP or signaling packets first diverge from the expected path.