Question 270
At Brookside Manufacturing, the plant operations team is planning an industrial Ethernet modernization under a requirement for planned downtime and resilient cabling. Following a proposed correction, the change manager requires evidence for this original fault: A new parallel link changes root-port selection and leaves one distribution path unexpectedly oversubscribed. Which observation BEST demonstrates that the fix worked?
Explanation
Correct Answer
STP operational output shows the approved root port and traffic follows the planned redundant path. This observation verifies the specific reported problem, A new parallel link changes root-port selection and leaves one distribution path unexpectedly oversubscribed. The intended correction was: Audit STP path cost and priority across the intended topology rather than swapping cable positions blindly. It provides a directly testable outcome for the Brookside Manufacturing environment rather than treating a completed change ticket as proof.
Incorrect Answers
Root and designated-port states match the approved topology with no unstable reconvergence. For Brookside Manufacturing, that measurement would support a separate technical case: A newly connected access switch becomes spanning-tree root and traffic begins traversing a low-bandwidth closet. Its corresponding remedy is: Set appropriate bridge priorities for the intended STP root and verify the region and topology. The reported Brookside Manufacturing condition is A new parallel link changes root-port selection and leaves one distribution path unexpectedly oversubscribed. So the required outcome is: STP operational output shows the approved root port and traffic follows the planned redundant path.
The test rogue bridge triggers the approved edge protection without changing the legitimate STP root. For Brookside Manufacturing, that measurement would support a separate technical case: A user-facing switch port repeatedly receives BPDUs from an unauthorized bridge connected under a desk. Its corresponding remedy is: Apply edge-port BPDU protection according to the endpoint access policy rather than allowing rogue root claims. The reported Brookside Manufacturing condition is A new parallel link changes root-port selection and leaves one distribution path unexpectedly oversubscribed. So the required outcome is: STP operational output shows the approved root port and traffic follows the planned redundant path.
The FortiSwitch topology retains its designated root and forwards through the approved stable paths. For Brookside Manufacturing, that measurement would support a separate technical case: The FortiLink topology joins another unmanaged switching domain that advertises an unexpected STP root. Its corresponding remedy is: Define controlled spanning-tree boundaries and root protection compatible with the supported FortiLink deployment. The reported Brookside Manufacturing condition is A new parallel link changes root-port selection and leaves one distribution path unexpectedly oversubscribed. So the required outcome is: STP operational output shows the approved root port and traffic follows the planned redundant path.