McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 40

Question 390

A server operations team encounters the following situation: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A database host failure preserves or restores service within the defined SLA.
  2. Loss of one rack or power path leaves a tested service path active.
  3. A link-failure test preserves service without MAC instability.
  4. Users retain required authenticated workflows across backend changes.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: A link-failure test preserves service without MAC instability. It verifies the action choose compatible NIC teaming with switch-independent failover or correctly configured LACP. The failure under test was: The host and switches disagree on link aggregation semantics.

Incorrect Answers

A:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A web service has redundant servers but their database connection points to a single nonredundant instance, defeating the application uptime goal. It may be true while the current failure persists; the decisive current cause is: The host and switches disagree on link aggregation semantics.

B:

This observation tests an unrelated Explain the key concepts of high availability for servers case: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. It may be true while the current failure persists; the decisive current cause is: The host and switches disagree on link aggregation semantics.

D:

This observation tests an unrelated Explain the key concepts of high availability for servers case: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. It may be true while the current failure persists; the decisive current cause is: The host and switches disagree on link aggregation semantics.

Question 391

A server operations team encounters the following situation: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. Which underlying cause most specifically explains the observed symptoms?

  1. Aggressive automatic failback can reduce service stability.
  2. Component-level disk redundancy is not server-level service resilience.
  3. End-to-end availability is limited by an unprotected backend dependency.
  4. The host and switches disagree on link aggregation semantics.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. The corrective step is: Choose compatible NIC teaming with switch-independent failover or correctly configured LACP. The verifying outcome is: A link-failure test preserves service without MAC instability.

Incorrect Answers

A:

This alternative cause would explain a different case: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. It does not explain the actual incident's evidence. The present cause is: The host and switches disagree on link aggregation semantics.

B:

This alternative cause would explain a different case: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. It does not explain the actual incident's evidence. The present cause is: The host and switches disagree on link aggregation semantics.

C:

This alternative cause would explain a different case: A web service has redundant servers but their database connection points to a single nonredundant instance, defeating the application uptime goal. It does not explain the actual incident's evidence. The present cause is: The host and switches disagree on link aggregation semantics.

Question 392

A server operations team encounters the following situation: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Validate both ends of a teamed interface configuration.
  2. Exercise flapping and recovery scenarios with cluster policies.
  3. Test node isolation and split-brain prevention under component outages.
  4. Include cross-node state continuity in load balancing acceptance.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: The host and switches disagree on link aggregation semantics. It builds validation into the affected workflow and supports the expected recovery result: A link-failure test preserves service without MAC instability.

Incorrect Answers

B:

This control addresses a different scenario: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. That event's root mechanism was aggressive automatic failback can reduce service stability. The described incident instead arises from: The host and switches disagree on link aggregation semantics.

C:

This control addresses a different scenario: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. That event's root mechanism was shared network dependencies can prevent reliable cluster coordination during a failure. The described incident instead arises from: The host and switches disagree on link aggregation semantics.

D:

This control addresses a different scenario: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. That event's root mechanism was active-active nodes do not share session state automatically. The described incident instead arises from: The host and switches disagree on link aggregation semantics.

Question 393

A server operations team encounters the following situation: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Use supported rolling maintenance with failover, dependency and rollback verification.
  2. Configure relevant backend health probes and remove failed nodes from service.
  3. Identify and mitigate remaining power and host-level failure risks.
  4. Align DNS failover strategy and TTL behavior with actual client caching limitations and RTO.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. The fault mechanism is component-level disk redundancy is not server-level service resilience. Expected confirmation is: A planned PSU or host failure meets documented service recovery expectations.

Incorrect Answers

A:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. That case involves: Concurrent maintenance eliminates intended redundancy. Here the observed mechanism is instead: Component-level disk redundancy is not server-level service resilience. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. That case involves: Round-robin scheduling does not substitute for backend health evaluation. Here the observed mechanism is instead: Component-level disk redundancy is not server-level service resilience. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A DNS-based failover strategy uses an hour-long record TTL despite an application recovery objective measured in minutes. That case involves: DNS caching can outlast intended backend recovery changes. Here the observed mechanism is instead: Component-level disk redundancy is not server-level service resilience. Applying the other repair would not directly resolve this fault.

Question 394

A server operations team encounters the following situation: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. One node can serve requests while its peer is patched in a controlled sequence.
  2. Loss of one rack or power path leaves a tested service path active.
  3. Requests stop reaching the failed backend while healthy nodes remain active.
  4. A planned PSU or host failure meets documented service recovery expectations.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: A planned PSU or host failure meets documented service recovery expectations. It verifies the action identify and mitigate remaining power and host-level failure risks. The failure under test was: Component-level disk redundancy is not server-level service resilience.

Incorrect Answers

A:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. It may be true while the current failure persists; the decisive current cause is: Component-level disk redundancy is not server-level service resilience.

B:

This observation tests an unrelated Explain the key concepts of high availability for servers case: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. It may be true while the current failure persists; the decisive current cause is: Component-level disk redundancy is not server-level service resilience.

C:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. It may be true while the current failure persists; the decisive current cause is: Component-level disk redundancy is not server-level service resilience.

Question 395

A server operations team encounters the following situation: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. Which underlying cause most specifically explains the observed symptoms?

  1. Component-level disk redundancy is not server-level service resilience.
  2. Active-active nodes do not share session state automatically.
  3. Logical cluster membership does not eliminate shared physical single points of failure.
  4. Heartbeat loss without split-brain controls can create conflicting cluster owners.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. The corrective step is: Identify and mitigate remaining power and host-level failure risks. The verifying outcome is: A planned PSU or host failure meets documented service recovery expectations.

Incorrect Answers

B:

This alternative cause would explain a different case: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. It does not explain the actual incident's evidence. The present cause is: Component-level disk redundancy is not server-level service resilience.

C:

This alternative cause would explain a different case: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. It does not explain the actual incident's evidence. The present cause is: Component-level disk redundancy is not server-level service resilience.

D:

This alternative cause would explain a different case: A two-node cluster has no quorum witness and both isolated hosts attempt ownership of a shared writable volume after heartbeat loss. It does not explain the actual incident's evidence. The present cause is: Component-level disk redundancy is not server-level service resilience.

Question 396

A server operations team encounters the following situation: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Map dependency redundancy rather than counting only front-end servers.
  2. Document availability across compute, network, power and storage tiers.
  3. Audit placement, power and network independence of all cluster members.
  4. Validate both ends of a teamed interface configuration.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Component-level disk redundancy is not server-level service resilience. It builds validation into the affected workflow and supports the expected recovery result: A planned PSU or host failure meets documented service recovery expectations.

Incorrect Answers

A:

This control addresses a different scenario: A web service has redundant servers but their database connection points to a single nonredundant instance, defeating the application uptime goal. That event's root mechanism was end-to-end availability is limited by an unprotected backend dependency. The described incident instead arises from: Component-level disk redundancy is not server-level service resilience.

C:

This control addresses a different scenario: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. That event's root mechanism was logical cluster membership does not eliminate shared physical single points of failure. The described incident instead arises from: Component-level disk redundancy is not server-level service resilience.

D:

This control addresses a different scenario: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. That event's root mechanism was the host and switches disagree on link aggregation semantics. The described incident instead arises from: Component-level disk redundancy is not server-level service resilience.

Question 397

A server operations team encounters the following situation: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Identify and mitigate remaining power and host-level failure risks.
  2. Configure supported quorum and fencing to prevent simultaneous writers.
  3. Use supported rolling maintenance with failover, dependency and rollback verification.
  4. Apply supported failback preferences and stability thresholds for the service.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. The fault mechanism is aggressive automatic failback can reduce service stability. Expected confirmation is: Repeated short outages do not produce unnecessary role flapping.

Incorrect Answers

A:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. That case involves: Component-level disk redundancy is not server-level service resilience. Here the observed mechanism is instead: Aggressive automatic failback can reduce service stability. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A two-node cluster has no quorum witness and both isolated hosts attempt ownership of a shared writable volume after heartbeat loss. That case involves: Heartbeat loss without split-brain controls can create conflicting cluster owners. Here the observed mechanism is instead: Aggressive automatic failback can reduce service stability. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. That case involves: Concurrent maintenance eliminates intended redundancy. Here the observed mechanism is instead: Aggressive automatic failback can reduce service stability. Applying the other repair would not directly resolve this fault.

Question 398

A server operations team encounters the following situation: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Repeated short outages do not produce unnecessary role flapping.
  2. A full primary failure leaves surviving nodes meeting measured service performance.
  3. A link-failure test preserves service without MAC instability.
  4. A partition test leaves exactly one node authorized to write.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: Repeated short outages do not produce unnecessary role flapping. It verifies the action apply supported failback preferences and stability thresholds for the service. The failure under test was: Aggressive automatic failback can reduce service stability.

Incorrect Answers

B:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A failover cluster has standby CPU capacity for only one-third of production workload while its active node runs near 90% load. It may be true while the current failure persists; the decisive current cause is: Aggressive automatic failback can reduce service stability.

C:

This observation tests an unrelated Explain the key concepts of high availability for servers case: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. It may be true while the current failure persists; the decisive current cause is: Aggressive automatic failback can reduce service stability.

D:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A two-node cluster has no quorum witness and both isolated hosts attempt ownership of a shared writable volume after heartbeat loss. It may be true while the current failure persists; the decisive current cause is: Aggressive automatic failback can reduce service stability.

Question 399

A server operations team encounters the following situation: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. Which underlying cause most specifically explains the observed symptoms?

  1. Concurrent maintenance eliminates intended redundancy.
  2. Aggressive automatic failback can reduce service stability.
  3. Heartbeat loss without split-brain controls can create conflicting cluster owners.
  4. Logical cluster membership does not eliminate shared physical single points of failure.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. The corrective step is: Apply supported failback preferences and stability thresholds for the service. The verifying outcome is: Repeated short outages do not produce unnecessary role flapping.

Incorrect Answers

A:

This alternative cause would explain a different case: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. It does not explain the actual incident's evidence. The present cause is: Aggressive automatic failback can reduce service stability.

C:

This alternative cause would explain a different case: A two-node cluster has no quorum witness and both isolated hosts attempt ownership of a shared writable volume after heartbeat loss. It does not explain the actual incident's evidence. The present cause is: Aggressive automatic failback can reduce service stability.

D:

This alternative cause would explain a different case: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. It does not explain the actual incident's evidence. The present cause is: Aggressive automatic failback can reduce service stability.

Question 400

A server operations team encounters the following situation: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Exercise unhealthy backend behavior before go-live.
  2. Test node isolation and split-brain prevention under component outages.
  3. Exercise flapping and recovery scenarios with cluster policies.
  4. Include network-partition tests in cluster recovery rehearsals.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Aggressive automatic failback can reduce service stability. It builds validation into the affected workflow and supports the expected recovery result: Repeated short outages do not produce unnecessary role flapping.

Incorrect Answers

A:

This control addresses a different scenario: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. That event's root mechanism was round-robin scheduling does not substitute for backend health evaluation. The described incident instead arises from: Aggressive automatic failback can reduce service stability.

B:

This control addresses a different scenario: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. That event's root mechanism was shared network dependencies can prevent reliable cluster coordination during a failure. The described incident instead arises from: Aggressive automatic failback can reduce service stability.

D:

This control addresses a different scenario: A two-node cluster has no quorum witness and both isolated hosts attempt ownership of a shared writable volume after heartbeat loss. That event's root mechanism was heartbeat loss without split-brain controls can create conflicting cluster owners. The described incident instead arises from: Aggressive automatic failback can reduce service stability.