McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 38

Question 370

A server operations team encounters the following situation: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Test clients reconnect within the declared recovery target under controlled failover.
  2. A controlled switch failure transitions service ownership cleanly to the surviving node.
  3. Users retain required authenticated workflows across backend changes.
  4. Requests stop reaching the failed backend while healthy nodes remain active.

Explanation

Correct Answer

B:

This is incident-specific acceptance evidence: A controlled switch failure transitions service ownership cleanly to the surviving node. It verifies the action separate heartbeat and service failure domains with supported redundant networking and fencing. The failure under test was: Shared network dependencies can prevent reliable cluster coordination during a failure.

Incorrect Answers

A:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A DNS-based failover strategy uses an hour-long record TTL despite an application recovery objective measured in minutes. It may be true while the current failure persists; the decisive current cause is: Shared network dependencies can prevent reliable cluster coordination during a failure.

C:

This observation tests an unrelated Explain the key concepts of high availability for servers case: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. It may be true while the current failure persists; the decisive current cause is: Shared network dependencies can prevent reliable cluster coordination during a failure.

D:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. It may be true while the current failure persists; the decisive current cause is: Shared network dependencies can prevent reliable cluster coordination during a failure.

Question 371

A server operations team encounters the following situation: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. Which underlying cause most specifically explains the observed symptoms?

  1. A standby configuration without adequate spare capacity does not meet service SLAs.
  2. Heartbeat loss without split-brain controls can create conflicting cluster owners.
  3. Shared network dependencies can prevent reliable cluster coordination during a failure.
  4. Logical cluster membership does not eliminate shared physical single points of failure.

Explanation

Correct Answer

C:

This root-cause explanation directly accounts for the reported condition: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. The corrective step is: Separate heartbeat and service failure domains with supported redundant networking and fencing. The verifying outcome is: A controlled switch failure transitions service ownership cleanly to the surviving node.

Incorrect Answers

A:

This alternative cause would explain a different case: A failover cluster has standby CPU capacity for only one-third of production workload while its active node runs near 90% load. It does not explain the actual incident's evidence. The present cause is: Shared network dependencies can prevent reliable cluster coordination during a failure.

B:

This alternative cause would explain a different case: A two-node cluster has no quorum witness and both isolated hosts attempt ownership of a shared writable volume after heartbeat loss. It does not explain the actual incident's evidence. The present cause is: Shared network dependencies can prevent reliable cluster coordination during a failure.

D:

This alternative cause would explain a different case: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. It does not explain the actual incident's evidence. The present cause is: Shared network dependencies can prevent reliable cluster coordination during a failure.

Question 372

A server operations team encounters the following situation: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Audit placement, power and network independence of all cluster members.
  2. Document availability across compute, network, power and storage tiers.
  3. Validate both ends of a teamed interface configuration.
  4. Test node isolation and split-brain prevention under component outages.

Explanation

Correct Answer

D:

This control targets the underlying recurrence risk: Shared network dependencies can prevent reliable cluster coordination during a failure. It builds validation into the affected workflow and supports the expected recovery result: A controlled switch failure transitions service ownership cleanly to the surviving node.

Incorrect Answers

A:

This control addresses a different scenario: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. That event's root mechanism was logical cluster membership does not eliminate shared physical single points of failure. The described incident instead arises from: Shared network dependencies can prevent reliable cluster coordination during a failure.

B:

This control addresses a different scenario: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. That event's root mechanism was component-level disk redundancy is not server-level service resilience. The described incident instead arises from: Shared network dependencies can prevent reliable cluster coordination during a failure.

C:

This control addresses a different scenario: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. That event's root mechanism was the host and switches disagree on link aggregation semantics. The described incident instead arises from: Shared network dependencies can prevent reliable cluster coordination during a failure.

Question 373

A server operations team encounters the following situation: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Separate infrastructure failure domains according to the actual resilience requirement.
  2. Configure relevant backend health probes and remove failed nodes from service.
  3. Choose compatible NIC teaming with switch-independent failover or correctly configured LACP.
  4. Separate heartbeat and service failure domains with supported redundant networking and fencing.

Explanation

Correct Answer

B:

The preferred corrective action directly addresses the incident: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. The fault mechanism is round-robin scheduling does not substitute for backend health evaluation. Expected confirmation is: Requests stop reaching the failed backend while healthy nodes remain active.

Incorrect Answers

A:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. That case involves: Logical cluster membership does not eliminate shared physical single points of failure. Here the observed mechanism is instead: Round-robin scheduling does not substitute for backend health evaluation. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. That case involves: The host and switches disagree on link aggregation semantics. Here the observed mechanism is instead: Round-robin scheduling does not substitute for backend health evaluation. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A two-node active-passive database cluster uses an identical heartbeat path and client uplink; one switch fault isolates both without reliable failover. That case involves: Shared network dependencies can prevent reliable cluster coordination during a failure. Here the observed mechanism is instead: Round-robin scheduling does not substitute for backend health evaluation. Applying the other repair would not directly resolve this fault.

Question 374

A server operations team encounters the following situation: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. One node can serve requests while its peer is patched in a controlled sequence.
  2. A full primary failure leaves surviving nodes meeting measured service performance.
  3. Requests stop reaching the failed backend while healthy nodes remain active.
  4. A link-failure test preserves service without MAC instability.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: Requests stop reaching the failed backend while healthy nodes remain active. It verifies the action configure relevant backend health probes and remove failed nodes from service. The failure under test was: Round-robin scheduling does not substitute for backend health evaluation.

Incorrect Answers

A:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. It may be true while the current failure persists; the decisive current cause is: Round-robin scheduling does not substitute for backend health evaluation.

B:

This observation tests an unrelated Explain the key concepts of high availability for servers case: A failover cluster has standby CPU capacity for only one-third of production workload while its active node runs near 90% load. It may be true while the current failure persists; the decisive current cause is: Round-robin scheduling does not substitute for backend health evaluation.

D:

This observation tests an unrelated Explain the key concepts of high availability for servers case: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. It may be true while the current failure persists; the decisive current cause is: Round-robin scheduling does not substitute for backend health evaluation.

Question 375

A server operations team encounters the following situation: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. Which underlying cause most specifically explains the observed symptoms?

  1. Concurrent maintenance eliminates intended redundancy.
  2. Active-active nodes do not share session state automatically.
  3. A standby configuration without adequate spare capacity does not meet service SLAs.
  4. Round-robin scheduling does not substitute for backend health evaluation.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. The corrective step is: Configure relevant backend health probes and remove failed nodes from service. The verifying outcome is: Requests stop reaching the failed backend while healthy nodes remain active.

Incorrect Answers

A:

This alternative cause would explain a different case: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. It does not explain the actual incident's evidence. The present cause is: Round-robin scheduling does not substitute for backend health evaluation.

B:

This alternative cause would explain a different case: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. It does not explain the actual incident's evidence. The present cause is: Round-robin scheduling does not substitute for backend health evaluation.

C:

This alternative cause would explain a different case: A failover cluster has standby CPU capacity for only one-third of production workload while its active node runs near 90% load. It does not explain the actual incident's evidence. The present cause is: Round-robin scheduling does not substitute for backend health evaluation.

Question 376

A server operations team encounters the following situation: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Exercise unhealthy backend behavior before go-live.
  2. Test production-sized failover loads periodically.
  3. Map dependency redundancy rather than counting only front-end servers.
  4. Include cross-node state continuity in load balancing acceptance.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Round-robin scheduling does not substitute for backend health evaluation. It builds validation into the affected workflow and supports the expected recovery result: Requests stop reaching the failed backend while healthy nodes remain active.

Incorrect Answers

B:

This control addresses a different scenario: A failover cluster has standby CPU capacity for only one-third of production workload while its active node runs near 90% load. That event's root mechanism was a standby configuration without adequate spare capacity does not meet service SLAs. The described incident instead arises from: Round-robin scheduling does not substitute for backend health evaluation.

C:

This control addresses a different scenario: A web service has redundant servers but their database connection points to a single nonredundant instance, defeating the application uptime goal. That event's root mechanism was end-to-end availability is limited by an unprotected backend dependency. The described incident instead arises from: Round-robin scheduling does not substitute for backend health evaluation.

D:

This control addresses a different scenario: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. That event's root mechanism was active-active nodes do not share session state automatically. The described incident instead arises from: Round-robin scheduling does not substitute for backend health evaluation.

Question 377

A server operations team encounters the following situation: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Configure relevant backend health probes and remove failed nodes from service.
  2. Choose compatible NIC teaming with switch-independent failover or correctly configured LACP.
  3. Use supported rolling maintenance with failover, dependency and rollback verification.
  4. Apply supported failback preferences and stability thresholds for the service.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. The fault mechanism is concurrent maintenance eliminates intended redundancy. Expected confirmation is: One node can serve requests while its peer is patched in a controlled sequence.

Incorrect Answers

A:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: A load balancer blindly distributes HTTP traffic to a dead backend because no application health check has been defined. That case involves: Round-robin scheduling does not substitute for backend health evaluation. Here the observed mechanism is instead: Concurrent maintenance eliminates intended redundancy. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. That case involves: The host and switches disagree on link aggregation semantics. Here the observed mechanism is instead: Concurrent maintenance eliminates intended redundancy. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Explain the key concepts of high availability for servers incident: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. That case involves: Aggressive automatic failback can reduce service stability. Here the observed mechanism is instead: Concurrent maintenance eliminates intended redundancy. Applying the other repair would not directly resolve this fault.

Question 378

A server operations team encounters the following situation: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. Users retain required authenticated workflows across backend changes.
  2. Loss of one rack or power path leaves a tested service path active.
  3. Repeated short outages do not produce unnecessary role flapping.
  4. One node can serve requests while its peer is patched in a controlled sequence.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: One node can serve requests while its peer is patched in a controlled sequence. It verifies the action use supported rolling maintenance with failover, dependency and rollback verification. The failure under test was: Concurrent maintenance eliminates intended redundancy.

Incorrect Answers

A:

This observation tests an unrelated Explain the key concepts of high availability for servers case: An active-active service writes sessions only to local memory and users are logged out whenever traffic moves to another healthy node. It may be true while the current failure persists; the decisive current cause is: Concurrent maintenance eliminates intended redundancy.

B:

This observation tests an unrelated Explain the key concepts of high availability for servers case: Two critical servers are in one rack and share one PDU, but operators describe their cluster as geo-redundant. It may be true while the current failure persists; the decisive current cause is: Concurrent maintenance eliminates intended redundancy.

C:

This observation tests an unrelated Explain the key concepts of high availability for servers case: An application cluster fails back immediately after a transient node recovery, causing repeated ownership oscillations during network instability. It may be true while the current failure persists; the decisive current cause is: Concurrent maintenance eliminates intended redundancy.

Question 379

A server operations team encounters the following situation: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. Which underlying cause most specifically explains the observed symptoms?

  1. Concurrent maintenance eliminates intended redundancy.
  2. Component-level disk redundancy is not server-level service resilience.
  3. DNS caching can outlast intended backend recovery changes.
  4. End-to-end availability is limited by an unprotected backend dependency.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. The corrective step is: Use supported rolling maintenance with failover, dependency and rollback verification. The verifying outcome is: One node can serve requests while its peer is patched in a controlled sequence.

Incorrect Answers

B:

This alternative cause would explain a different case: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. It does not explain the actual incident's evidence. The present cause is: Concurrent maintenance eliminates intended redundancy.

C:

This alternative cause would explain a different case: A DNS-based failover strategy uses an hour-long record TTL despite an application recovery objective measured in minutes. It does not explain the actual incident's evidence. The present cause is: Concurrent maintenance eliminates intended redundancy.

D:

This alternative cause would explain a different case: A web service has redundant servers but their database connection points to a single nonredundant instance, defeating the application uptime goal. It does not explain the actual incident's evidence. The present cause is: Concurrent maintenance eliminates intended redundancy.

Question 380

A server operations team encounters the following situation: A cluster administrator patches both active and standby servers simultaneously to reduce maintenance time and takes the entire service offline. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Document availability across compute, network, power and storage tiers.
  2. Plan cluster patching around one-failure-at-a-time resilience.
  3. Validate effective client behavior rather than assuming resolver TTL guarantees.
  4. Validate both ends of a teamed interface configuration.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: Concurrent maintenance eliminates intended redundancy. It builds validation into the affected workflow and supports the expected recovery result: One node can serve requests while its peer is patched in a controlled sequence.

Incorrect Answers

A:

This control addresses a different scenario: A file server has mirrored disks but an unprotected PSU and no alternate server, although management calls it fully fault tolerant. That event's root mechanism was component-level disk redundancy is not server-level service resilience. The described incident instead arises from: Concurrent maintenance eliminates intended redundancy.

C:

This control addresses a different scenario: A DNS-based failover strategy uses an hour-long record TTL despite an application recovery objective measured in minutes. That event's root mechanism was dNS caching can outlast intended backend recovery changes. The described incident instead arises for this situation: Concurrent maintenance eliminates intended redundancy.

D:

This control addresses a different scenario: Two physical NICs are bonded in an unsupported aggregation mode across separate switches without matching switch configuration; traffic drops intermittently. That event's root mechanism was the host and switches disagree on link aggregation semantics. The described incident instead arises from: Concurrent maintenance eliminates intended redundancy.