McAfee-Secured Website

Exam Bundle

Exam Code: CAS-005

Exam Name CompTIA SecurityX

Certification Provider: CompTIA

Corresponding Certification: CASP

CompTIA CAS-005 Bundle $44.99

100% CompTIA CAS-005 Guaranteed Success With Testking Training Materials

Get Real CAS-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    CAS-005 Questions & Answers

    482 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual CAS-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • CAS-005 Video Course

    CAS-005 Video Course

    180 Video Lectures

    CAS-005 Video Course is developed by CompTIA Professionals to help you pass the CAS-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA SecurityX exam.
  • Study Guide

    CAS-005 Study Guide

    903 PDF Pages

    Developed by industry experts, this 903-page guide spells out in painstaking detail all of the information you need to ace CAS-005 exam.

CompTIA SecurityX (CAS-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    482 Questions

    $124.99
  • CAS-005 Video Course

    Video Course

    180 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    903 PDF Pages

    $29.99

CompTIA CAS-005 Practice Test 39

Question 380

Which test or documented result best shows that the underlying issue was properly addressed? A legacy power-grid control server cannot run EDR and has no software support for modern authentication.

  1. Simulated network retries create one authorized account change and one auditable result.
  2. Direct office-network connections fail and authorized maintenance sessions are recorded.
  3. A staged maintenance test preserves plant process continuity and confirms dependency restoration.
  4. An external test cannot reach the controller management service while authorized facility technicians can.

Explanation

Correct Answer

B:

This is direct test evidence of the control objective in the case: A legacy power-grid control server cannot run EDR and has no software support for modern authentication. It demonstrates that the proposed response, place the server behind controlled jump hosts and segmented OT boundaries with compensating monitoring., produces the measurable result direct office-network connections fail and authorized maintenance sessions are recorded. The observation tests a relevant security outcome rather than an unrelated control or reporting activity.

Incorrect Answers

A:

“Simulated network retries create one authorized account change and one auditable result” would verify “Add idempotent action identifiers and bounded retry logic with explicit status checks” for the situation “A SOC playbook's webhook retries duplicate the same account-disable action and break an incident recovery workflow”. Here the required evidence is “Direct office-network connections fail and authorized maintenance sessions are recorded” after “Place the server behind controlled jump hosts and segmented OT boundaries with compensating monitoring”; the alternative observation does not test that control.

C:

In the problem “A legacy power-grid control server cannot run EDR and has no software support for modern authentication”, evidence “A staged maintenance test preserves plant process continuity and confirms dependency restoration.” is not decisive because it tests “A utility's safety engineers cannot document which OT assets depend on an unsupported Windows host before patching”; the requested validation is direct office-network connections fail and authorized maintenance sessions are recorded.

D:

For the issue “A legacy power-grid control server cannot run EDR and has no software support for modern authentication”, measuring “An external test cannot reach the controller management service while authorized facility technicians can.” would validate “A smart building HVAC controller exposes an undocumented management port to the public internet” instead of the required control effect: direct office-network connections fail and authorized maintenance sessions are recorded.

Question 381

A senior engineer examines the following finding: An industrial robot controller accepts unauthenticated configuration updates over its plant network. Which action most directly addresses the requirement?

  1. Establish vendor-supported update certification, offline test cycles, and maintenance authority before automation.
  2. Use passive inventory and vendor-approved low-impact assessment methods, isolating controllers from ordinary IT.
  3. Use authenticated encrypted transport tunnels with approved certificate validation.
  4. Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported.

Explanation

Correct Answer

D:

Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported. The acceptance check is that unauthorized workstations cannot change controller settings in an approved bench test. That outcome checks whether the requirement is met, rather than treating completion of a security task as proof of effectiveness.

Incorrect Answers

A:

The proposal “Establish vendor-supported update certification, offline test cycles, and maintenance authority before automation” manages “An enterprise faces this security constraint: A factory operator wants to deploy a generic automated patching agent to controllers with proprietary firmware”, where successful operation means “An update rehearsal preserves controller function and demonstrates validated rollback capability”. The present issue instead needs “Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported” to establish “Unauthorized workstations cannot change controller settings in an approved bench test”.

B:

Although “Use passive inventory and vendor-approved low-impact assessment methods, isolating controllers from ordinary IT.” is a reasonable response to “A hospital's infusion controllers are vulnerable to active network scans that occasionally reset dosing interfaces”, this case instead concerns “An industrial robot controller accepts unauthenticated configuration updates over its plant network”, for which success requires that unauthorized workstations cannot change controller settings in an approved bench test.

C:

The option “Use authenticated encrypted transport tunnels with approved certificate validation.” assumes an issue like “An internal application sends confidential backups over plaintext transport between regional data centers”, not the specific observed weakness “An industrial robot controller accepts unauthenticated configuration updates over its plant network”; it leaves the evidence goal unmet: unauthorized workstations cannot change controller settings in an approved bench test.

Question 382

A follow-up assurance review considers this problem: An industrial robot controller accepts unauthenticated configuration updates over its plant network. Which outcome best shows the intended improvement?

  1. An external test cannot reach the controller management service while authorized facility technicians can.
  2. A test unauthorized host cannot unlock the drive and custody transfers are recorded.
  3. Guest devices cannot reach safes and approved cloud telemetry is attributable to each unit.
  4. Unauthorized workstations cannot change controller settings in an approved bench test.

Explanation

Correct Answer

D:

This is direct test evidence of the control objective in the case: An industrial robot controller accepts unauthenticated configuration updates over its plant network. It demonstrates that the proposed response, restrict update paths to an approved engineering station and require signed or authenticated configuration where supported., produces the measurable result unauthorized workstations cannot change controller settings in an approved bench test. The observation tests a relevant security outcome rather than an unrelated control or reporting activity.

Incorrect Answers

A:

In the problem “An industrial robot controller accepts unauthenticated configuration updates over its plant network”, evidence “An external test cannot reach the controller management service while authorized facility technicians can.” is not decisive because it tests “A smart building HVAC controller exposes an undocumented management port to the public internet”; the requested validation is unauthorized workstations cannot change controller settings in an approved bench test.

B:

For the issue “An industrial robot controller accepts unauthenticated configuration updates over its plant network”, measuring “A test unauthorized host cannot unlock the drive and custody transfers are recorded.” would validate “A portable hard drive used for emergency data export has no tamper response and relies on a reusable software-only password” instead of the required control effect: unauthorized workstations cannot change controller settings in an approved bench test.

C:

In “A financial branch's smart safes connect over the same VLAN as visitor Wi-Fi and communicate through unmonitored cloud services”, “Guest devices cannot reach safes and approved cloud telemetry is attributable to each unit” is the acceptance signal for “Segment physical-security IoT devices and apply allowlisted egress with asset-level logging”. The required proof for the selected response “Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported” is “Unauthorized workstations cannot change controller settings in an approved bench test”.

Question 383

An enterprise faces this security constraint: A smart building HVAC controller exposes an undocumented management port to the public internet. Which proposal best addresses the stated risk?

  1. Isolate the devices behind access-controlled gateways and establish replacement and exception plans.
  2. Remove public reachability and restrict administration through monitored private access.
  3. Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported.
  4. Restrict legacy flows and require phishing-resistant authentication for privileged access.

Explanation

Correct Answer

B:

Remove public reachability and restrict administration through monitored private access. The acceptance check is that an external test cannot reach the controller management service while authorized facility technicians can. That outcome checks whether the requirement is met, rather than treating completion of a security task as proof of effectiveness.

Incorrect Answers

A:

The option “Isolate the devices behind access-controlled gateways and establish replacement and exception plans.” assumes an issue like “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users”, not the specific observed weakness “A smart building HVAC controller exposes an undocumented management port to the public internet”; it leaves the evidence goal unmet: an external test cannot reach the controller management service while authorized facility technicians can.

C:

The proposal “Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported” manages “An industrial robot controller accepts unauthenticated configuration updates over its plant network”, where successful operation means “Unauthorized workstations cannot change controller settings in an approved bench test”. The present issue instead needs “Remove public reachability and restrict administration through monitored private access” to establish “An external test cannot reach the controller management service while authorized facility technicians can”.

D:

Although “Restrict legacy flows and require phishing-resistant authentication for privileged access.” is a reasonable response to “A company introduces passkeys but privileged accounts still accept password-only legacy authentication from external networks”, this case instead concerns “A smart building HVAC controller exposes an undocumented management port to the public internet”, for which success requires that an external test cannot reach the controller management service while authorized facility technicians can.

Question 384

After the team responds to the following issue, which finding best demonstrates the desired security outcome? A smart building HVAC controller exposes an undocumented management port to the public internet.

  1. Unauthorized workstations cannot change controller settings in an approved bench test.
  2. An external test cannot reach the controller management service while authorized facility technicians can.
  3. Only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.
  4. The service principal can read its required bucket but cannot delete another account's data.

Explanation

Correct Answer

B:

This is direct test evidence of the control objective in the case: A smart building HVAC controller exposes an undocumented management port to the public internet. It demonstrates that the proposed response, remove public reachability and restrict administration through monitored private access., produces the measurable result an external test cannot reach the controller management service while authorized facility technicians can. The observation tests a relevant security outcome rather than an unrelated control or reporting activity.

Incorrect Answers

A:

In “An industrial robot controller accepts unauthenticated configuration updates over its plant network”, “Unauthorized workstations cannot change controller settings in an approved bench test” is the acceptance signal for “Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported”. The required proof for the selected response “Remove public reachability and restrict administration through monitored private access” is “An external test cannot reach the controller management service while authorized facility technicians can”.

C:

In the problem “A smart building HVAC controller exposes an undocumented management port to the public internet”, evidence “Only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.” is not decisive because it tests “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users”; the requested validation is an external test cannot reach the controller management service while authorized facility technicians can.

D:

This measurement is tied to “An enterprise faces this security constraint: A service principal used by billing has a role permitting deletion of every cloud storage account rather than its single billing bucket” and the control “Scope cloud IAM actions and resources to the billing workload and remove unrelated destructive privileges”. It cannot confirm that “Remove public reachability and restrict administration through monitored private access” has achieved “An external test cannot reach the controller management service while authorized facility technicians can” for the issue in this question.

Question 385

An enterprise security review reports: A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open. Which response best addresses the underlying security issue?

  1. Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported.
  2. Assess environmental and hardware-failure behavior and enforce a safe degraded operating mode.
  3. Enforce a versioned configuration baseline with automated drift assessment and policy-controlled changes.
  4. Enforce cryptographic device identity and per-device message authentication at ingestion.

Explanation

Correct Answer

B:

Assess environmental and hardware-failure behavior and enforce a safe degraded operating mode. The acceptance check is that controlled interference testing does not expose privileged diagnostics or unsafe commands. That outcome checks whether the requirement is met, rather than treating completion of a security task as proof of effectiveness.

Incorrect Answers

A:

The proposal “Restrict update paths to an approved engineering station and require signed or authenticated configuration where supported” manages “An industrial robot controller accepts unauthenticated configuration updates over its plant network”, where successful operation means “Unauthorized workstations cannot change controller settings in an approved bench test”. The present issue instead needs “Assess environmental and hardware-failure behavior and enforce a safe degraded operating mode” to establish “Controlled interference testing does not expose privileged diagnostics or unsafe commands”.

C:

The option “Enforce a versioned configuration baseline with automated drift assessment and policy-controlled changes.” assumes an issue like “A server group receives inconsistent hardening changes because administrators modify each host manually after provisioning”, not the specific observed weakness “A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open”; it leaves the evidence goal unmet: controlled interference testing does not expose privileged diagnostics or unsafe commands.

D:

“A forged serial-number message is rejected and valid devices remain accepted” would be meaningful evidence for “Enforce cryptographic device identity and per-device message authentication at ingestion” in the case “An IoT fleet sends telemetry to an aggregator that accepts messages from any device claiming an enrolled serial number”. It does not replace “Assess environmental and hardware-failure behavior and enforce a safe degraded operating mode” to correct “A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open” and verify “Controlled interference testing does not expose privileged diagnostics or unsafe commands”.

Question 386

Which test or documented result best shows that the underlying issue was properly addressed? A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open.

  1. Unauthorized workstations cannot change controller settings in an approved bench test.
  2. Monitoring identifies anomalies while schedule-critical commands meet latency thresholds.
  3. A break-glass test traces commands and approval to the requesting administrator.
  4. Controlled interference testing does not expose privileged diagnostics or unsafe commands.

Explanation

Correct Answer

D:

This is direct test evidence of the control objective in the case: A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open. It demonstrates that the proposed response, assess environmental and hardware-failure behavior and enforce a safe degraded operating mode., produces the measurable result controlled interference testing does not expose privileged diagnostics or unsafe commands. The observation tests a relevant security outcome rather than an unrelated control or reporting activity.

Incorrect Answers

A:

In the problem “A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open”, evidence “Unauthorized workstations cannot change controller settings in an approved bench test.” is not decisive because it tests “An industrial robot controller accepts unauthenticated configuration updates over its plant network”; the requested validation is controlled interference testing does not expose privileged diagnostics or unsafe commands.

B:

For the issue “A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open”, measuring “Monitoring identifies anomalies while schedule-critical commands meet latency thresholds.” would validate “A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand” instead of the required control effect: controlled interference testing does not expose privileged diagnostics or unsafe commands.

C:

“Implement checked-out emergency access with individual authorization and privileged session capture” should produce “A break-glass test traces commands and approval to the requesting administrator” in its own test case. The present requirement is instead checked by “Controlled interference testing does not expose privileged diagnostics or unsafe commands”, which validates “Assess environmental and hardware-failure behavior and enforce a safe degraded operating mode” rather than the alternate control.

Question 387

During an authorized security assessment, the team discovers: A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users. What should be prioritized?

  1. Place the server behind controlled jump hosts and segmented OT boundaries with compensating monitoring.
  2. Investigate device compliance and conditional access evaluation before granting a narrowly justified exception.
  3. Isolate the devices behind access-controlled gateways and establish replacement and exception plans.
  4. Segment physical-security IoT devices and apply allowlisted egress with asset-level logging.

Explanation

Correct Answer

C:

Isolate the devices behind access-controlled gateways and establish replacement and exception plans. The acceptance check is that only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved. That outcome checks whether the requirement is met, rather than treating completion of a security task as proof of effectiveness.

Incorrect Answers

A:

The option “Place the server behind controlled jump hosts and segmented OT boundaries with compensating monitoring.” assumes an issue like “A legacy power-grid control server cannot run EDR and has no software support for modern authentication”, not the specific observed weakness “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users”; it leaves the evidence goal unmet: only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.

B:

For “An enterprise account is denied an app because device risk posture has changed, but support tries to bypass all conditional access policies”, “Investigate device compliance and conditional access evaluation before granting a narrowly justified exception” has a clear validation signal: “A remediated device receives the intended access while the untrusted device still fails”. But “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users” calls for “Isolate the devices behind access-controlled gateways and establish replacement and exception plans”; the other intervention cannot demonstrate “Only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved”.

D:

Although “Segment physical-security IoT devices and apply allowlisted egress with asset-level logging.” is a reasonable response to “A financial branch's smart safes connect over the same VLAN as visitor Wi-Fi and communicate through unmonitored cloud services”, this case instead concerns “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users”, for which success requires that only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.

Question 388

A follow-up assurance review considers this problem: A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users. Which outcome best shows the intended improvement?

  1. An external test cannot reach the controller management service while authorized facility technicians can.
  2. Guest devices cannot reach safes and approved cloud telemetry is attributable to each unit.
  3. A test case exits quarantine only after authorized clearance and records the complete action trail.
  4. Only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.

Explanation

Correct Answer

D:

This is direct test evidence of the control objective in the case: A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users. It demonstrates that the proposed response, isolate the devices behind access-controlled gateways and establish replacement and exception plans., produces the measurable result only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved. The observation tests a relevant security outcome rather than an unrelated control or reporting activity.

Incorrect Answers

A:

In “An enterprise faces this security constraint: A smart building HVAC controller exposes an undocumented management port to the public internet”, “An external test cannot reach the controller management service while authorized facility technicians can” is the acceptance signal for “Remove public reachability and restrict administration through monitored private access”. The required proof for the selected response “Isolate the devices behind access-controlled gateways and establish replacement and exception plans” is “Only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved”.

B:

Observation “Guest devices cannot reach safes and approved cloud telemetry is attributable to each unit.” would be useful for “A financial branch's smart safes connect over the same VLAN as visitor Wi-Fi and communicate through unmonitored cloud services”, but it does not prove that the response to “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users” achieved the relevant outcome, only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.

C:

In the problem “A manufacturing network contains unsupported devices whose fixed default passwords cannot be changed by users”, evidence “A test case exits quarantine only after authorized clearance and records the complete action trail.” is not decisive because it tests “An automated threat feed applies quarantine labels that never expire after an incident has been closed”; the requested validation is only authorized gateway identities reach the legacy interfaces and the replacement timeline is approved.

Question 389

A cross-functional security group is considering a decision: A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand. What is the most appropriate control or investigation response?

  1. Place the server behind controlled jump hosts and segmented OT boundaries with compensating monitoring.
  2. Prefer safety-tested passive monitoring and carefully validated inline controls only where the protocol allows.
  3. Apply context-aware secure access controls, managed device posture, and approved tunnel routing.
  4. Use passive inventory and vendor-approved low-impact assessment methods, isolating controllers from ordinary IT.

Explanation

Correct Answer

B:

Prefer safety-tested passive monitoring and carefully validated inline controls only where the protocol allows. The acceptance check is that monitoring identifies anomalies while schedule-critical commands meet latency thresholds. That outcome checks whether the requirement is met, rather than treating completion of a security task as proof of effectiveness.

Incorrect Answers

A:

This choice would be evaluated by “Direct office-network connections fail and authorized maintenance sessions are recorded” when dealing with “A legacy power-grid control server cannot run EDR and has no software support for modern authentication”. It does not deliver the distinct control “Prefer safety-tested passive monitoring and carefully validated inline controls only where the protocol allows” needed for “A cross-functional security group is considering a decision: A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand”.

C:

The option “Apply context-aware secure access controls, managed device posture, and approved tunnel routing.” assumes an issue like “A remote network access design permits unrestricted split tunneling from unmanaged home networks to a confidential research service”, not the specific observed weakness “A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand”; it leaves the evidence goal unmet: monitoring identifies anomalies while schedule-critical commands meet latency thresholds.

D:

This choice would be evaluated by “Device visibility improves without restarts or interruption to clinical care” when dealing with “A hospital's infusion controllers are vulnerable to active network scans that occasionally reset dosing interfaces”. It does not deliver the distinct control “Prefer safety-tested passive monitoring and carefully validated inline controls only where the protocol allows” needed for “A cross-functional security group is considering a decision: A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand”.

Question 390

After the team responds to the following issue, which finding best demonstrates the desired security outcome? A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand.

  1. Controlled interference testing does not expose privileged diagnostics or unsafe commands.
  2. Monitoring identifies anomalies while schedule-critical commands meet latency thresholds.
  3. An external test cannot reach the controller management service while authorized facility technicians can.
  4. A swapped module fails attestation and the change record identifies the maintenance event.

Explanation

Correct Answer

B:

This is direct test evidence of the control objective in the case: A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand. It demonstrates that the proposed response, prefer safety-tested passive monitoring and carefully validated inline controls only where the protocol allows., produces the measurable result monitoring identifies anomalies while schedule-critical commands meet latency thresholds. The observation tests a relevant security outcome rather than an unrelated control or reporting activity.

Incorrect Answers

A:

In the problem “A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand”, evidence “Controlled interference testing does not expose privileged diagnostics or unsafe commands.” is not decisive because it tests “A defense supplier's embedded radio device must operate in an electromagnetic interference environment but its diagnostic interface fails open”; the requested validation is monitoring identifies anomalies while schedule-critical commands meet latency thresholds.

C:

“Remove public reachability and restrict administration through monitored private access” should produce “An external test cannot reach the controller management service while authorized facility technicians can” in its own test case. The present requirement is instead checked by “Monitoring identifies anomalies while schedule-critical commands meet latency thresholds”, which validates “Prefer safety-tested passive monitoring and carefully validated inline controls only where the protocol allows” rather than the alternate control.

D:

Observation “A swapped module fails attestation and the change record identifies the maintenance event.” would be useful for “A government workstation lacks a process to detect replacement of its trusted hardware security module during maintenance”, but it does not prove that the response to “A transit system's control network uses time-sensitive industrial traffic that a new inline IPS disrupts during peak demand” achieved the relevant outcome, monitoring identifies anomalies while schedule-critical commands meet latency thresholds.