McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 49

Question 480

A storage array reports rebuild in progress and a technician proposes removing another apparently slow disk. After the appropriate change, which observation BEST verifies the intended result?

  1. Recovered files validate against backup hashes on healthy storage.
  2. The controller reports a completed healthy rebuild.
  3. Measured I/O latency and queue depth fall under representative transactions.
  4. The array returns to healthy mirrored status with data intact.

Explanation

Correct Answer

B:

Removing additional members during a degraded rebuild risks data loss. The outcome “The controller reports a completed healthy rebuild.” verifies the action “Keep remaining healthy disks online until the rebuild completes and investigate non-disruptively.” for this situation: A storage array reports rebuild in progress and a technician proposes removing another apparently slow disk.

Incorrect Answers

A:

Mechanical clicking plus failed reads suggests physical drive failure. For the situation described—A storage array reports rebuild in progress and a technician proposes removing another apparently slow disk—this would not demonstrate the specified intervention. The relevant evidence is “The controller reports a completed healthy rebuild.”.

C:

Healthy disks can still be performance-bottlenecked by excessive demand. For the situation described—A storage array reports rebuild in progress and a technician proposes removing another apparently slow disk—this would not demonstrate the specified intervention. The relevant evidence is “The controller reports a completed healthy rebuild.”.

D:

RAID 1 tolerates a single member failure through mirroring. For the situation described—A storage array reports rebuild in progress and a technician proposes removing another apparently slow disk—this would not demonstrate the specified intervention. The relevant evidence is “The controller reports a completed healthy rebuild.”.

Question 481

A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics. Which action is MOST appropriate for this situation?

  1. Restore partition metadata or the system image from a trusted backup.
  2. Select the correct OS boot entry in firmware.
  3. Stop stressing the drive and recover data from backups or specialist service.
  4. Back up immediately and replace the suspect SSD.

Explanation

Correct Answer

A:

Logical corruption can prevent boot without physical media failure. In this situation—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics—the right response is “Restore partition metadata or the system image from a trusted backup.”. A confirming result would be “The correct partitions mount and file-system checks pass.”.

Incorrect Answers

B:

Firmware enumeration proves a storage device exists; wrong boot selection can still stop startup. That does not directly address the condition described—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics. “Restore partition metadata or the system image from a trusted backup.” is the appropriate response because logical corruption can prevent boot without physical media failure.

C:

Mechanical clicking plus failed reads suggests physical drive failure. That does not directly address the condition described—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics. “Restore partition metadata or the system image from a trusted backup.” is the appropriate response because logical corruption can prevent boot without physical media failure.

D:

SMART health warnings can precede irreversible storage failure. That does not directly address the condition described—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics. “Restore partition metadata or the system image from a trusted backup.” is the appropriate response because logical corruption can prevent boot without physical media failure.

Question 482

A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics. After the appropriate change, which observation BEST verifies the intended result?

  1. The installed operating system launches without disk replacement.
  2. The correct partitions mount and file-system checks pass.
  3. Recovered files validate against backup hashes on healthy storage.
  4. The new drive completes diagnostics without critical media errors.

Explanation

Correct Answer

B:

Logical corruption can prevent boot without physical media failure. The outcome “The correct partitions mount and file-system checks pass.” verifies the action “Restore partition metadata or the system image from a trusted backup.” for this situation: A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics.

Incorrect Answers

A:

Firmware enumeration proves a storage device exists; wrong boot selection can still stop startup. For the situation described—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics—this would not demonstrate the specified intervention. The relevant evidence is “The correct partitions mount and file-system checks pass.”.

C:

Mechanical clicking plus failed reads suggests physical drive failure. For the situation described—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics—this would not demonstrate the specified intervention. The relevant evidence is “The correct partitions mount and file-system checks pass.”.

D:

SMART health warnings can precede irreversible storage failure. For the situation described—A boot disk partition table is damaged by an interrupted imaging task but the disk passes SMART and surface diagnostics—this would not demonstrate the specified intervention. The relevant evidence is “The correct partitions mount and file-system checks pass.”.

Question 483

A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose. Which action is MOST appropriate for this situation?

  1. Move to a compatible PCIe/NVMe slot or use a supported device.
  2. Power off, reseat and secure the NVMe module.
  3. Provide the supported power feed or powered enclosure.
  4. Back up immediately and replace the suspect SSD.

Explanation

Correct Answer

B:

Poor electrical seating can produce intermittent storage detection. In this situation—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose—the right response is “Power off, reseat and secure the NVMe module.”. A confirming result would be “Multiple cold boots enumerate the NVMe drive consistently.”.

Incorrect Answers

A:

M.2 slot shape does not guarantee NVMe protocol support. That does not directly address the condition described—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose. “Power off, reseat and secure the NVMe module.” is the appropriate response because poor electrical seating can produce intermittent storage detection.

C:

Spinning disks can draw more power than a weak USB port supplies. That does not directly address the condition described—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose. “Power off, reseat and secure the NVMe module.” is the appropriate response because poor electrical seating can produce intermittent storage detection.

D:

SMART health warnings can precede irreversible storage failure. That does not directly address the condition described—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose. “Power off, reseat and secure the NVMe module.” is the appropriate response because poor electrical seating can produce intermittent storage detection.

Question 484

A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware detects the drive at the intended interface.
  2. Multiple cold boots enumerate the NVMe drive consistently.
  3. The drive remains mounted during spin-up and sustained transfers.
  4. The new drive completes diagnostics without critical media errors.

Explanation

Correct Answer

B:

Poor electrical seating can produce intermittent storage detection. The outcome “Multiple cold boots enumerate the NVMe drive consistently.” verifies the action “Power off, reseat and secure the NVMe module.” for this situation: A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose.

Incorrect Answers

A:

M.2 slot shape does not guarantee NVMe protocol support. For the situation described—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose—this would not demonstrate the specified intervention. The relevant evidence is “Multiple cold boots enumerate the NVMe drive consistently.”.

C:

Spinning disks can draw more power than a weak USB port supplies. For the situation described—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose—this would not demonstrate the specified intervention. The relevant evidence is “Multiple cold boots enumerate the NVMe drive consistently.”.

D:

SMART health warnings can precede irreversible storage failure. For the situation described—A workstation's NVMe drive is intermittently absent after thermal expansion and the retaining screw is loose—this would not demonstrate the specified intervention. The relevant evidence is “Multiple cold boots enumerate the NVMe drive consistently.”.

Question 485

A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume. Which action is MOST appropriate for this situation?

  1. Rebalance I/O or upgrade the storage performance tier for the workload.
  2. Stop stressing the drive and recover data from backups or specialist service.
  3. Keep remaining healthy disks online until the rebuild completes and investigate non-disruptively.
  4. Replace the failed member and allow a monitored mirror rebuild.

Explanation

Correct Answer

A:

Healthy disks can still be performance-bottlenecked by excessive demand. In this situation—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume—the right response is “Rebalance I/O or upgrade the storage performance tier for the workload.”. A confirming result would be “Measured I/O latency and queue depth fall under representative transactions.”.

Incorrect Answers

B:

Mechanical clicking plus failed reads suggests physical drive failure. That does not directly address the condition described—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume. “Rebalance I/O or upgrade the storage performance tier for the workload.” is the appropriate response because healthy disks can still be performance-bottlenecked by excessive demand.

C:

Removing additional members during a degraded rebuild risks data loss. That does not directly address the condition described—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume. “Rebalance I/O or upgrade the storage performance tier for the workload.” is the appropriate response because healthy disks can still be performance-bottlenecked by excessive demand.

D:

RAID 1 tolerates a single member failure through mirroring. That does not directly address the condition described—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume. “Rebalance I/O or upgrade the storage performance tier for the workload.” is the appropriate response because healthy disks can still be performance-bottlenecked by excessive demand.

Question 486

A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume. After the appropriate change, which observation BEST verifies the intended result?

  1. Recovered files validate against backup hashes on healthy storage.
  2. The controller reports a completed healthy rebuild.
  3. The installed operating system launches without disk replacement.
  4. Measured I/O latency and queue depth fall under representative transactions.

Explanation

Correct Answer

D:

Healthy disks can still be performance-bottlenecked by excessive demand. The outcome “Measured I/O latency and queue depth fall under representative transactions.” verifies the action “Rebalance I/O or upgrade the storage performance tier for the workload.” for this situation: A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume.

Incorrect Answers

A:

Mechanical clicking plus failed reads suggests physical drive failure. For the situation described—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume—this would not demonstrate the specified intervention. The relevant evidence is “Measured I/O latency and queue depth fall under representative transactions.”.

B:

Removing additional members during a degraded rebuild risks data loss. For the situation described—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume—this would not demonstrate the specified intervention. The relevant evidence is “Measured I/O latency and queue depth fall under representative transactions.”.

C:

Firmware enumeration proves a storage device exists; wrong boot selection can still stop startup. For the situation described—A database server is slow although disk health is normal; monitoring shows queue depth and latency saturating one shared volume—this would not demonstrate the specified intervention. The relevant evidence is “Measured I/O latency and queue depth fall under representative transactions.”.

Question 487

An external USB hard drive disconnects whenever its bus-powered enclosure spins up. Which action is MOST appropriate for this situation?

  1. Power off, reseat and secure the NVMe module.
  2. Move to a compatible PCIe/NVMe slot or use a supported device.
  3. Provide the supported power feed or powered enclosure.
  4. Stop stressing the drive and recover data from backups or specialist service.

Explanation

Correct Answer

C:

Spinning disks can draw more power than a weak USB port supplies. In this situation—An external USB hard drive disconnects whenever its bus-powered enclosure spins up—the right response is “Provide the supported power feed or powered enclosure.”. A confirming result would be “The drive remains mounted during spin-up and sustained transfers.”.

Incorrect Answers

A:

Poor electrical seating can produce intermittent storage detection. That does not directly address the condition described—An external USB hard drive disconnects whenever its bus-powered enclosure spins up. “Provide the supported power feed or powered enclosure.” is the appropriate response because spinning disks can draw more power than a weak USB port supplies.

B:

M.2 slot shape does not guarantee NVMe protocol support. That does not directly address the condition described—An external USB hard drive disconnects whenever its bus-powered enclosure spins up. “Provide the supported power feed or powered enclosure.” is the appropriate response because spinning disks can draw more power than a weak USB port supplies.

D:

Mechanical clicking plus failed reads suggests physical drive failure. That does not directly address the condition described—An external USB hard drive disconnects whenever its bus-powered enclosure spins up. “Provide the supported power feed or powered enclosure.” is the appropriate response because spinning disks can draw more power than a weak USB port supplies.

Question 488

An external USB hard drive disconnects whenever its bus-powered enclosure spins up. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware detects the drive at the intended interface.
  2. Multiple cold boots enumerate the NVMe drive consistently.
  3. The drive remains mounted during spin-up and sustained transfers.
  4. Recovered files validate against backup hashes on healthy storage.

Explanation

Correct Answer

C:

Spinning disks can draw more power than a weak USB port supplies. The outcome “The drive remains mounted during spin-up and sustained transfers.” verifies the action “Provide the supported power feed or powered enclosure.” for this situation: An external USB hard drive disconnects whenever its bus-powered enclosure spins up.

Incorrect Answers

A:

M.2 slot shape does not guarantee NVMe protocol support. For the situation described—An external USB hard drive disconnects whenever its bus-powered enclosure spins up—this would not demonstrate the specified intervention. The relevant evidence is “The drive remains mounted during spin-up and sustained transfers.”.

B:

Poor electrical seating can produce intermittent storage detection. For the situation described—An external USB hard drive disconnects whenever its bus-powered enclosure spins up—this would not demonstrate the specified intervention. The relevant evidence is “The drive remains mounted during spin-up and sustained transfers.”.

D:

Mechanical clicking plus failed reads suggests physical drive failure. For the situation described—An external USB hard drive disconnects whenever its bus-powered enclosure spins up—this would not demonstrate the specified intervention. The relevant evidence is “The drive remains mounted during spin-up and sustained transfers.”.

Question 489

A cloned SSD boots to a missing-bootloader error despite intact user data. Which action is MOST appropriate for this situation?

  1. Select the correct OS boot entry in firmware.
  2. Move to a compatible PCIe/NVMe slot or use a supported device.
  3. Repair the correct UEFI/EFI boot configuration on the cloned device.
  4. Back up immediately and replace the suspect SSD.

Explanation

Correct Answer

C:

Cloning data does not always preserve a working firmware boot registration. In this situation—A cloned SSD boots to a missing-bootloader error despite intact user data—the right response is “Repair the correct UEFI/EFI boot configuration on the cloned device.”. A confirming result would be “The cloned system boots and accessible files match the source.”.

Incorrect Answers

A:

Firmware enumeration proves a storage device exists; wrong boot selection can still stop startup. That does not directly address the condition described—A cloned SSD boots to a missing-bootloader error despite intact user data. “Repair the correct UEFI/EFI boot configuration on the cloned device.” is the appropriate response because cloning data does not always preserve a working firmware boot registration.

B:

M.2 slot shape does not guarantee NVMe protocol support. That does not directly address the condition described—A cloned SSD boots to a missing-bootloader error despite intact user data. “Repair the correct UEFI/EFI boot configuration on the cloned device.” is the appropriate response because cloning data does not always preserve a working firmware boot registration.

D:

SMART health warnings can precede irreversible storage failure. That does not directly address the condition described—A cloned SSD boots to a missing-bootloader error despite intact user data. “Repair the correct UEFI/EFI boot configuration on the cloned device.” is the appropriate response because cloning data does not always preserve a working firmware boot registration.

Question 490

A cloned SSD boots to a missing-bootloader error despite intact user data. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware detects the drive at the intended interface.
  2. The new drive completes diagnostics without critical media errors.
  3. Multiple cold boots enumerate the NVMe drive consistently.
  4. The cloned system boots and accessible files match the source.

Explanation

Correct Answer

D:

Cloning data does not always preserve a working firmware boot registration. The outcome “The cloned system boots and accessible files match the source.” verifies the action “Repair the correct UEFI/EFI boot configuration on the cloned device.” for this situation: A cloned SSD boots to a missing-bootloader error despite intact user data.

Incorrect Answers

A:

M.2 slot shape does not guarantee NVMe protocol support. For the situation described—A cloned SSD boots to a missing-bootloader error despite intact user data—this would not demonstrate the specified intervention. The relevant evidence is “The cloned system boots and accessible files match the source.”.

B:

SMART health warnings can precede irreversible storage failure. For the situation described—A cloned SSD boots to a missing-bootloader error despite intact user data—this would not demonstrate the specified intervention. The relevant evidence is “The cloned system boots and accessible files match the source.”.

C:

Poor electrical seating can produce intermittent storage detection. For the situation described—A cloned SSD boots to a missing-bootloader error despite intact user data—this would not demonstrate the specified intervention. The relevant evidence is “The cloned system boots and accessible files match the source.”.