McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 34

Question 330

A desktop built for one electrical region is moved to another with a different mains supply. After the appropriate change, which observation BEST verifies the intended result?

  1. Input-power measurements show acceptable losses at normal workload.
  2. The device receives the specified DC input and runs without faults.
  3. The PSU input specification matches the destination mains and boots safely.
  4. The workstation remains stable during representative peak power loading.

Explanation

Correct Answer

C:

Incorrect mains input settings can damage a supply. The outcome “The PSU input specification matches the destination mains and boots safely.” verifies the action “Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.” for this situation: A desktop built for one electrical region is moved to another with a different mains supply.

Incorrect Answers

A:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A desktop built for one electrical region is moved to another with a different mains supply—this would not demonstrate the specified intervention. The relevant evidence is “The PSU input specification matches the destination mains and boots safely.”.

B:

Mismatched polarity or voltage can damage electronics. For the situation described—A desktop built for one electrical region is moved to another with a different mains supply—this would not demonstrate the specified intervention. The relevant evidence is “The PSU input specification matches the destination mains and boots safely.”.

D:

Insufficient PSU capacity can cause resets or shutdown under load. For the situation described—A desktop built for one electrical region is moved to another with a different mains supply—this would not demonstrate the specified intervention. The relevant evidence is “The PSU input specification matches the destination mains and boots safely.”.

Question 331

An always-on office desktop seeks lower power waste under typical loads. Which action is MOST appropriate for this situation?

  1. Use an adapter matching required voltage, polarity, connector and current rating.
  2. Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.
  3. Choose an appropriately sized PSU with suitable certified conversion efficiency.
  4. Use the replacement PSU's approved modular cable set only.

Explanation

Correct Answer

C:

Higher-efficiency supplies waste less energy as heat at a given load. In this situation—An always-on office desktop seeks lower power waste under typical loads—the right response is “Choose an appropriately sized PSU with suitable certified conversion efficiency.”. A confirming result would be “Input-power measurements show acceptable losses at normal workload.”.

Incorrect Answers

A:

Mismatched polarity or voltage can damage electronics. That does not directly address the condition described—An always-on office desktop seeks lower power waste under typical loads. “Choose an appropriately sized PSU with suitable certified conversion efficiency.” is the appropriate response because higher-efficiency supplies waste less energy as heat at a given load.

B:

Incorrect mains input settings can damage a supply. That does not directly address the condition described—An always-on office desktop seeks lower power waste under typical loads. “Choose an appropriately sized PSU with suitable certified conversion efficiency.” is the appropriate response because higher-efficiency supplies waste less energy as heat at a given load.

D:

Modular PSU-side pinouts can differ even if device-side connectors look identical. That does not directly address the condition described—An always-on office desktop seeks lower power waste under typical loads. “Choose an appropriately sized PSU with suitable certified conversion efficiency.” is the appropriate response because higher-efficiency supplies waste less energy as heat at a given load.

Question 332

An always-on office desktop seeks lower power waste under typical loads. After the appropriate change, which observation BEST verifies the intended result?

  1. The device receives the specified DC input and runs without faults.
  2. Input-power measurements show acceptable losses at normal workload.
  3. The system powers and POSTs without CPU power warnings.
  4. The PSU input specification matches the destination mains and boots safely.

Explanation

Correct Answer

B:

Higher-efficiency supplies waste less energy as heat at a given load. The outcome “Input-power measurements show acceptable losses at normal workload.” verifies the action “Choose an appropriately sized PSU with suitable certified conversion efficiency.” for this situation: An always-on office desktop seeks lower power waste under typical loads.

Incorrect Answers

A:

Mismatched polarity or voltage can damage electronics. For the situation described—An always-on office desktop seeks lower power waste under typical loads—this would not demonstrate the specified intervention. The relevant evidence is “Input-power measurements show acceptable losses at normal workload.”.

C:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. For the situation described—An always-on office desktop seeks lower power waste under typical loads—this would not demonstrate the specified intervention. The relevant evidence is “Input-power measurements show acceptable losses at normal workload.”.

D:

Incorrect mains input settings can damage a supply. For the situation described—An always-on office desktop seeks lower power waste under typical loads—this would not demonstrate the specified intervention. The relevant evidence is “Input-power measurements show acceptable losses at normal workload.”.

Question 333

A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity. Which action is MOST appropriate for this situation?

  1. Use the proper EPS CPU power connector from the PSU.
  2. Use an adapter matching required voltage, polarity, connector and current rating.
  3. Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.
  4. Choose an appropriately sized PSU with suitable certified conversion efficiency.

Explanation

Correct Answer

B:

Mismatched polarity or voltage can damage electronics. In this situation—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity—the right response is “Use an adapter matching required voltage, polarity, connector and current rating.”. A confirming result would be “The device receives the specified DC input and runs without faults.”.

Incorrect Answers

A:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. That does not directly address the condition described—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity. “Use an adapter matching required voltage, polarity, connector and current rating.” is the appropriate response because mismatched polarity or voltage can damage electronics.

C:

Incorrect mains input settings can damage a supply. That does not directly address the condition described—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity. “Use an adapter matching required voltage, polarity, connector and current rating.” is the appropriate response because mismatched polarity or voltage can damage electronics.

D:

Higher-efficiency supplies waste less energy as heat at a given load. That does not directly address the condition described—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity. “Use an adapter matching required voltage, polarity, connector and current rating.” is the appropriate response because mismatched polarity or voltage can damage electronics.

Question 334

A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity. After the appropriate change, which observation BEST verifies the intended result?

  1. The system powers and POSTs without CPU power warnings.
  2. The device receives the specified DC input and runs without faults.
  3. Input-power measurements show acceptable losses at normal workload.
  4. The PSU input specification matches the destination mains and boots safely.

Explanation

Correct Answer

B:

Mismatched polarity or voltage can damage electronics. The outcome “The device receives the specified DC input and runs without faults.” verifies the action “Use an adapter matching required voltage, polarity, connector and current rating.” for this situation: A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity.

Incorrect Answers

A:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. For the situation described—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity—this would not demonstrate the specified intervention. The relevant evidence is “The device receives the specified DC input and runs without faults.”.

C:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity—this would not demonstrate the specified intervention. The relevant evidence is “The device receives the specified DC input and runs without faults.”.

D:

Incorrect mains input settings can damage a supply. For the situation described—A mini-PC's external power adapter is lost and a similar-looking adapter has opposite barrel polarity—this would not demonstrate the specified intervention. The relevant evidence is “The device receives the specified DC input and runs without faults.”.

Question 335

A Windows department installs a network laser printer but jobs render as random characters with a generic driver. Which action is MOST appropriate for this situation?

  1. Install the manufacturer's appropriate PCL or PostScript-capable driver.
  2. Configure printer discovery using its reachable wired IP or print server.
  3. Use a duplex-capable automatic document feeder where supported.
  4. Apply the authorized and compatible printer firmware update.

Explanation

Correct Answer

A:

An incompatible printer language driver can cause garbled output. In this situation—A Windows department installs a network laser printer but jobs render as random characters with a generic driver—the right response is “Install the manufacturer's appropriate PCL or PostScript-capable driver.”. A confirming result would be “A complex test document prints correctly with fonts and page breaks.”.

Incorrect Answers

B:

Printer attachment method determines discovery and IP reachability. That does not directly address the condition described—A Windows department installs a network laser printer but jobs render as random characters with a generic driver. “Install the manufacturer's appropriate PCL or PostScript-capable driver.” is the appropriate response because an incompatible printer language driver can cause garbled output.

C:

An ADF transports multi-page documents unlike a stationary flatbed. That does not directly address the condition described—A Windows department installs a network laser printer but jobs render as random characters with a generic driver. “Install the manufacturer's appropriate PCL or PostScript-capable driver.” is the appropriate response because an incompatible printer language driver can cause garbled output.

D:

Firmware controls embedded printer networking and device behavior. That does not directly address the condition described—A Windows department installs a network laser printer but jobs render as random characters with a generic driver. “Install the manufacturer's appropriate PCL or PostScript-capable driver.” is the appropriate response because an incompatible printer language driver can cause garbled output.

Question 336

A Windows department installs a network laser printer but jobs render as random characters with a generic driver. After the appropriate change, which observation BEST verifies the intended result?

  1. A complex test document prints correctly with fonts and page breaks.
  2. A queued test page prints only after the authorized PIN is entered.
  3. The printer reports the intended firmware version and test printing works.
  4. Clients discover and print to the printer through the wired LAN.

Explanation

Correct Answer

A:

An incompatible printer language driver can cause garbled output. The outcome “A complex test document prints correctly with fonts and page breaks.” verifies the action “Install the manufacturer's appropriate PCL or PostScript-capable driver.” for this situation: A Windows department installs a network laser printer but jobs render as random characters with a generic driver.

Incorrect Answers

B:

Pull printing prevents confidential pages from sitting unattended. For the situation described—A Windows department installs a network laser printer but jobs render as random characters with a generic driver—this would not demonstrate the specified intervention. The relevant evidence is “A complex test document prints correctly with fonts and page breaks.”.

C:

Firmware controls embedded printer networking and device behavior. For the situation described—A Windows department installs a network laser printer but jobs render as random characters with a generic driver—this would not demonstrate the specified intervention. The relevant evidence is “A complex test document prints correctly with fonts and page breaks.”.

D:

Printer attachment method determines discovery and IP reachability. For the situation described—A Windows department installs a network laser printer but jobs render as random characters with a generic driver—this would not demonstrate the specified intervention. The relevant evidence is “A complex test document prints correctly with fonts and page breaks.”.

Question 337

A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages. Which action is MOST appropriate for this situation?

  1. Enable centralized print accounting with authenticated identities.
  2. Enable secure-hold printing with authenticated release.
  3. Configure printer discovery using its reachable wired IP or print server.
  4. Configure the destination share path and least-privilege SMB credentials.

Explanation

Correct Answer

B:

Pull printing prevents confidential pages from sitting unattended. In this situation—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages—the right response is “Enable secure-hold printing with authenticated release.”. A confirming result would be “A queued test page prints only after the authorized PIN is entered.”.

Incorrect Answers

A:

Authentication and print logs provide job attribution. That does not directly address the condition described—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages. “Enable secure-hold printing with authenticated release.” is the appropriate response because pull printing prevents confidential pages from sitting unattended.

C:

Printer attachment method determines discovery and IP reachability. That does not directly address the condition described—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages. “Enable secure-hold printing with authenticated release.” is the appropriate response because pull printing prevents confidential pages from sitting unattended.

D:

Scan-to-folder requires reachable SMB service and sufficient write rights. That does not directly address the condition described—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages. “Enable secure-hold printing with authenticated release.” is the appropriate response because pull printing prevents confidential pages from sitting unattended.

Question 338

A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages. After the appropriate change, which observation BEST verifies the intended result?

  1. A complex test document prints correctly with fonts and page breaks.
  2. The scan captures the page without bending or tearing it.
  3. A queued test page prints only after the authorized PIN is entered.
  4. A standard new job prints both sides in grayscale.

Explanation

Correct Answer

C:

Pull printing prevents confidential pages from sitting unattended. The outcome “A queued test page prints only after the authorized PIN is entered.” verifies the action “Enable secure-hold printing with authenticated release.” for this situation: A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages.

Incorrect Answers

A:

An incompatible printer language driver can cause garbled output. For the situation described—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages—this would not demonstrate the specified intervention. The relevant evidence is “A queued test page prints only after the authorized PIN is entered.”.

B:

Flatbed scanning avoids the mechanical transport used by document feeders. For the situation described—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages—this would not demonstrate the specified intervention. The relevant evidence is “A queued test page prints only after the authorized PIN is entered.”.

D:

Queue defaults can reduce paper and toner usage across clients. For the situation described—A shared office printer must require staff to enter a PIN before releasing sensitive payroll pages—this would not demonstrate the specified intervention. The relevant evidence is “A queued test page prints only after the authorized PIN is entered.”.

Question 339

A multifunction device must scan signed forms to a shared folder using SMB. Which action is MOST appropriate for this situation?

  1. Use a duplex-capable automatic document feeder where supported.
  2. Enable secure-hold printing with authenticated release.
  3. Configure the destination share path and least-privilege SMB credentials.
  4. Set queue defaults for two-sided monochrome output.

Explanation

Correct Answer

C:

Scan-to-folder requires reachable SMB service and sufficient write rights. In this situation—A multifunction device must scan signed forms to a shared folder using SMB—the right response is “Configure the destination share path and least-privilege SMB credentials.”. A confirming result would be “A scanned PDF appears in the allowed share and access is logged.”.

Incorrect Answers

A:

An ADF transports multi-page documents unlike a stationary flatbed. That does not directly address the condition described—A multifunction device must scan signed forms to a shared folder using SMB. “Configure the destination share path and least-privilege SMB credentials.” is the appropriate response because scan-to-folder requires reachable SMB service and sufficient write rights.

B:

Pull printing prevents confidential pages from sitting unattended. That does not directly address the condition described—A multifunction device must scan signed forms to a shared folder using SMB. “Configure the destination share path and least-privilege SMB credentials.” is the appropriate response because scan-to-folder requires reachable SMB service and sufficient write rights.

D:

Queue defaults can reduce paper and toner usage across clients. That does not directly address the condition described—A multifunction device must scan signed forms to a shared folder using SMB. “Configure the destination share path and least-privilege SMB credentials.” is the appropriate response because scan-to-folder requires reachable SMB service and sufficient write rights.

Question 340

A multifunction device must scan signed forms to a shared folder using SMB. After the appropriate change, which observation BEST verifies the intended result?

  1. All pages are scanned in order with both sides visible.
  2. A scanned PDF appears in the allowed share and access is logged.
  3. A queued test page prints only after the authorized PIN is entered.
  4. The scan captures the page without bending or tearing it.

Explanation

Correct Answer

B:

Scan-to-folder requires reachable SMB service and sufficient write rights. The outcome “A scanned PDF appears in the allowed share and access is logged.” verifies the action “Configure the destination share path and least-privilege SMB credentials.” for this situation: A multifunction device must scan signed forms to a shared folder using SMB.

Incorrect Answers

A:

An ADF transports multi-page documents unlike a stationary flatbed. For the situation described—A multifunction device must scan signed forms to a shared folder using SMB—this would not demonstrate the specified intervention. The relevant evidence is “A scanned PDF appears in the allowed share and access is logged.”.

C:

Pull printing prevents confidential pages from sitting unattended. For the situation described—A multifunction device must scan signed forms to a shared folder using SMB—this would not demonstrate the specified intervention. The relevant evidence is “A scanned PDF appears in the allowed share and access is logged.”.

D:

Flatbed scanning avoids the mechanical transport used by document feeders. For the situation described—A multifunction device must scan signed forms to a shared folder using SMB—this would not demonstrate the specified intervention. The relevant evidence is “A scanned PDF appears in the allowed share and access is logged.”.