McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 33

Question 320

A remote management board asks for a compatible Wi-Fi radio card to add wireless connectivity. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware/OS enumerate the WLAN device and it associates with a test AP.
  2. Audio inputs enumerate and a test recording is captured.
  3. The operating system identifies the adapter and it passes a network test.
  4. Firmware identifies the processor and POST completes.

Explanation

Correct Answer

A:

Expansion connector and antenna support must match the chosen network card. The outcome “Firmware/OS enumerate the WLAN device and it associates with a test AP.” verifies the action “Select the correct M.2/PCIe wireless card and antennas supported by the board.” for this situation: A remote management board asks for a compatible Wi-Fi radio card to add wireless connectivity.

Incorrect Answers

B:

An expansion audio card provides interfaces beyond onboard audio. For the situation described—A remote management board asks for a compatible Wi-Fi radio card to add wireless connectivity—this would not demonstrate the specified intervention. The relevant evidence is “Firmware/OS enumerate the WLAN device and it associates with a test AP.”.

C:

Hardware detection alone may not provide a functional interface driver. For the situation described—A remote management board asks for a compatible Wi-Fi radio card to add wireless connectivity—this would not demonstrate the specified intervention. The relevant evidence is “Firmware/OS enumerate the WLAN device and it associates with a test AP.”.

D:

CPU socket fit and BIOS compatibility are mandatory. For the situation described—A remote management board asks for a compatible Wi-Fi radio card to add wireless connectivity—this would not demonstrate the specified intervention. The relevant evidence is “Firmware/OS enumerate the WLAN device and it associates with a test AP.”.

Question 321

A workstation requires 650 W under peak load and a technician selects a 400 W supply. Which action is MOST appropriate for this situation?

  1. Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.
  2. Specify a quality PSU with sufficient continuous output and headroom.
  3. Choose an appropriately sized PSU with suitable certified conversion efficiency.
  4. Use the replacement PSU's approved modular cable set only.

Explanation

Correct Answer

B:

Insufficient PSU capacity can cause resets or shutdown under load. In this situation—A workstation requires 650 W under peak load and a technician selects a 400 W supply—the right response is “Specify a quality PSU with sufficient continuous output and headroom.”. A confirming result would be “The workstation remains stable during representative peak power loading.”.

Incorrect Answers

A:

Incorrect mains input settings can damage a supply. That does not directly address the condition described—A workstation requires 650 W under peak load and a technician selects a 400 W supply. “Specify a quality PSU with sufficient continuous output and headroom.” is the appropriate response because insufficient PSU capacity can cause resets or shutdown under load.

C:

Higher-efficiency supplies waste less energy as heat at a given load. That does not directly address the condition described—A workstation requires 650 W under peak load and a technician selects a 400 W supply. “Specify a quality PSU with sufficient continuous output and headroom.” is the appropriate response because insufficient PSU capacity can cause resets or shutdown under load.

D:

Modular PSU-side pinouts can differ even if device-side connectors look identical. That does not directly address the condition described—A workstation requires 650 W under peak load and a technician selects a 400 W supply. “Specify a quality PSU with sufficient continuous output and headroom.” is the appropriate response because insufficient PSU capacity can cause resets or shutdown under load.

Question 322

A workstation requires 650 W under peak load and a technician selects a 400 W supply. After the appropriate change, which observation BEST verifies the intended result?

  1. The PSU input specification matches the destination mains and boots safely.
  2. The workstation remains stable during representative peak power loading.
  3. Input-power measurements show acceptable losses at normal workload.
  4. The system powers and POSTs without CPU power warnings.

Explanation

Correct Answer

B:

Insufficient PSU capacity can cause resets or shutdown under load. The outcome “The workstation remains stable during representative peak power loading.” verifies the action “Specify a quality PSU with sufficient continuous output and headroom.” for this situation: A workstation requires 650 W under peak load and a technician selects a 400 W supply.

Incorrect Answers

A:

Incorrect mains input settings can damage a supply. For the situation described—A workstation requires 650 W under peak load and a technician selects a 400 W supply—this would not demonstrate the specified intervention. The relevant evidence is “The workstation remains stable during representative peak power loading.”.

C:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A workstation requires 650 W under peak load and a technician selects a 400 W supply—this would not demonstrate the specified intervention. The relevant evidence is “The workstation remains stable during representative peak power loading.”.

D:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. For the situation described—A workstation requires 650 W under peak load and a technician selects a 400 W supply—this would not demonstrate the specified intervention. The relevant evidence is “The workstation remains stable during representative peak power loading.”.

Question 323

A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand. Which action is MOST appropriate for this situation?

  1. Use the replacement PSU's approved modular cable set only.
  2. Use the proper EPS CPU power connector from the PSU.
  3. Choose an appropriately sized PSU with suitable certified conversion efficiency.
  4. Use an adapter matching required voltage, polarity, connector and current rating.

Explanation

Correct Answer

A:

Modular PSU-side pinouts can differ even if device-side connectors look identical. In this situation—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand—the right response is “Use the replacement PSU's approved modular cable set only.”. A confirming result would be “Each connector and voltage passes an approved safety inspection.”.

Incorrect Answers

B:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. That does not directly address the condition described—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand. “Use the replacement PSU's approved modular cable set only.” is the appropriate response because modular PSU-side pinouts can differ even if device-side connectors look identical.

C:

Higher-efficiency supplies waste less energy as heat at a given load. That does not directly address the condition described—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand. “Use the replacement PSU's approved modular cable set only.” is the appropriate response because modular PSU-side pinouts can differ even if device-side connectors look identical.

D:

Mismatched polarity or voltage can damage electronics. That does not directly address the condition described—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand. “Use the replacement PSU's approved modular cable set only.” is the appropriate response because modular PSU-side pinouts can differ even if device-side connectors look identical.

Question 324

A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand. After the appropriate change, which observation BEST verifies the intended result?

  1. The system powers and POSTs without CPU power warnings.
  2. Input-power measurements show acceptable losses at normal workload.
  3. Each connector and voltage passes an approved safety inspection.
  4. The device receives the specified DC input and runs without faults.

Explanation

Correct Answer

C:

Modular PSU-side pinouts can differ even if device-side connectors look identical. The outcome “Each connector and voltage passes an approved safety inspection.” verifies the action “Use the replacement PSU's approved modular cable set only.” for this situation: A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand.

Incorrect Answers

A:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. For the situation described—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand—this would not demonstrate the specified intervention. The relevant evidence is “Each connector and voltage passes an approved safety inspection.”.

B:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand—this would not demonstrate the specified intervention. The relevant evidence is “Each connector and voltage passes an approved safety inspection.”.

D:

Mismatched polarity or voltage can damage electronics. For the situation described—A modular PSU is replaced, but an installer wants to reuse modular power leads from a different PSU brand—this would not demonstrate the specified intervention. The relevant evidence is “Each connector and voltage passes an approved safety inspection.”.

Question 325

A rack server has two redundant hot-swap PSU bays and one unit fails. Which action is MOST appropriate for this situation?

  1. Use an adapter matching required voltage, polarity, connector and current rating.
  2. Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.
  3. Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.
  4. Choose an appropriately sized PSU with suitable certified conversion efficiency.

Explanation

Correct Answer

B:

Redundant PSU design can tolerate a single power module failure. In this situation—A rack server has two redundant hot-swap PSU bays and one unit fails—the right response is “Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.”. A confirming result would be “Both power modules report healthy redundancy after replacement.”.

Incorrect Answers

A:

Mismatched polarity or voltage can damage electronics. That does not directly address the condition described—A rack server has two redundant hot-swap PSU bays and one unit fails. “Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.” is the appropriate response because redundant PSU design can tolerate a single power module failure.

C:

Incorrect mains input settings can damage a supply. That does not directly address the condition described—A rack server has two redundant hot-swap PSU bays and one unit fails. “Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.” is the appropriate response because redundant PSU design can tolerate a single power module failure.

D:

Higher-efficiency supplies waste less energy as heat at a given load. That does not directly address the condition described—A rack server has two redundant hot-swap PSU bays and one unit fails. “Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.” is the appropriate response because redundant PSU design can tolerate a single power module failure.

Question 326

A rack server has two redundant hot-swap PSU bays and one unit fails. After the appropriate change, which observation BEST verifies the intended result?

  1. The system powers and POSTs without CPU power warnings.
  2. Both power modules report healthy redundancy after replacement.
  3. Input-power measurements show acceptable losses at normal workload.
  4. The workstation remains stable during representative peak power loading.

Explanation

Correct Answer

B:

Redundant PSU design can tolerate a single power module failure. The outcome “Both power modules report healthy redundancy after replacement.” verifies the action “Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.” for this situation: A rack server has two redundant hot-swap PSU bays and one unit fails.

Incorrect Answers

A:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. For the situation described—A rack server has two redundant hot-swap PSU bays and one unit fails—this would not demonstrate the specified intervention. The relevant evidence is “Both power modules report healthy redundancy after replacement.”.

C:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A rack server has two redundant hot-swap PSU bays and one unit fails—this would not demonstrate the specified intervention. The relevant evidence is “Both power modules report healthy redundancy after replacement.”.

D:

Insufficient PSU capacity can cause resets or shutdown under load. For the situation described—A rack server has two redundant hot-swap PSU bays and one unit fails—this would not demonstrate the specified intervention. The relevant evidence is “Both power modules report healthy redundancy after replacement.”.

Question 327

A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available. Which action is MOST appropriate for this situation?

  1. Use an adapter matching required voltage, polarity, connector and current rating.
  2. Use the replacement PSU's approved modular cable set only.
  3. Choose an appropriately sized PSU with suitable certified conversion efficiency.
  4. Use the proper EPS CPU power connector from the PSU.

Explanation

Correct Answer

D:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. In this situation—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available—the right response is “Use the proper EPS CPU power connector from the PSU.”. A confirming result would be “The system powers and POSTs without CPU power warnings.”.

Incorrect Answers

A:

Mismatched polarity or voltage can damage electronics. That does not directly address the condition described—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available. “Use the proper EPS CPU power connector from the PSU.” is the appropriate response because ePS12V CPU and PCIe GPU power connectors are not interchangeable.

B:

Modular PSU-side pinouts can differ even if device-side connectors look identical. That does not directly address the condition described—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available. “Use the proper EPS CPU power connector from the PSU.” is the appropriate response because ePS12V CPU and PCIe GPU power connectors are not interchangeable.

C:

Higher-efficiency supplies waste less energy as heat at a given load. That does not directly address the condition described—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available. “Use the proper EPS CPU power connector from the PSU.” is the appropriate response because ePS12V CPU and PCIe GPU power connectors are not interchangeable.

Question 328

A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available. After the appropriate change, which observation BEST verifies the intended result?

  1. The device receives the specified DC input and runs without faults.
  2. Input-power measurements show acceptable losses at normal workload.
  3. Both power modules report healthy redundancy after replacement.
  4. The system powers and POSTs without CPU power warnings.

Explanation

Correct Answer

D:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. The outcome “The system powers and POSTs without CPU power warnings.” verifies the action “Use the proper EPS CPU power connector from the PSU.” for this situation: A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available.

Incorrect Answers

A:

Mismatched polarity or voltage can damage electronics. For the situation described—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available—this would not demonstrate the specified intervention. The relevant evidence is “The system powers and POSTs without CPU power warnings.”.

B:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available—this would not demonstrate the specified intervention. The relevant evidence is “The system powers and POSTs without CPU power warnings.”.

C:

Redundant PSU design can tolerate a single power module failure. For the situation described—A motherboard needs an 8-pin EPS CPU power feed and a spare 8-pin PCIe graphics plug is available—this would not demonstrate the specified intervention. The relevant evidence is “The system powers and POSTs without CPU power warnings.”.

Question 329

A desktop built for one electrical region is moved to another with a different mains supply. Which action is MOST appropriate for this situation?

  1. Use an adapter matching required voltage, polarity, connector and current rating.
  2. Choose an appropriately sized PSU with suitable certified conversion efficiency.
  3. Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.
  4. Specify a quality PSU with sufficient continuous output and headroom.

Explanation

Correct Answer

C:

Incorrect mains input settings can damage a supply. In this situation—A desktop built for one electrical region is moved to another with a different mains supply—the right response is “Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.”. A confirming result would be “The PSU input specification matches the destination mains and boots safely.”.

Incorrect Answers

A:

Mismatched polarity or voltage can damage electronics. That does not directly address the condition described—A desktop built for one electrical region is moved to another with a different mains supply. “Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.” is the appropriate response because incorrect mains input settings can damage a supply.

B:

Higher-efficiency supplies waste less energy as heat at a given load. That does not directly address the condition described—A desktop built for one electrical region is moved to another with a different mains supply. “Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.” is the appropriate response because incorrect mains input settings can damage a supply.

D:

Insufficient PSU capacity can cause resets or shutdown under load. That does not directly address the condition described—A desktop built for one electrical region is moved to another with a different mains supply. “Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.” is the appropriate response because incorrect mains input settings can damage a supply.

Question 330

A desktop built for one electrical region is moved to another with a different mains supply. After the appropriate change, which observation BEST verifies the intended result?

  1. Input-power measurements show acceptable losses at normal workload.
  2. The device receives the specified DC input and runs without faults.
  3. The PSU input specification matches the destination mains and boots safely.
  4. The workstation remains stable during representative peak power loading.

Explanation

Correct Answer

C:

Incorrect mains input settings can damage a supply. The outcome “The PSU input specification matches the destination mains and boots safely.” verifies the action “Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.” for this situation: A desktop built for one electrical region is moved to another with a different mains supply.

Incorrect Answers

A:

Higher-efficiency supplies waste less energy as heat at a given load. For the situation described—A desktop built for one electrical region is moved to another with a different mains supply—this would not demonstrate the specified intervention. The relevant evidence is “The PSU input specification matches the destination mains and boots safely.”.

B:

Mismatched polarity or voltage can damage electronics. For the situation described—A desktop built for one electrical region is moved to another with a different mains supply—this would not demonstrate the specified intervention. The relevant evidence is “The PSU input specification matches the destination mains and boots safely.”.

D:

Insufficient PSU capacity can cause resets or shutdown under load. For the situation described—A desktop built for one electrical region is moved to another with a different mains supply—this would not demonstrate the specified intervention. The relevant evidence is “The PSU input specification matches the destination mains and boots safely.”.