McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 28

Question 270

A field laptop has all memory soldered and no expansion slot, yet an upgrade kit was requested. After the appropriate change, which observation BEST verifies the intended result?

  1. The memory fits the keyed slot and firmware detects it.
  2. Firmware reports the supported capacity with a passing memory test.
  3. Firmware reports ECC enabled and diagnostic events are available.
  4. Device specifications confirm the required usable capacity.

Explanation

Correct Answer

D:

Soldered memory cannot be swapped like a socketed SO-DIMM. The outcome “Device specifications confirm the required usable capacity.” verifies the action “Use a replacement model or platform with sufficient installed memory.” for this situation: A field laptop has all memory soldered and no expansion slot, yet an upgrade kit was requested.

Incorrect Answers

A:

SO-DIMMs are the compact module form commonly used in laptops. For the situation described—A field laptop has all memory soldered and no expansion slot, yet an upgrade kit was requested—this would not demonstrate the specified intervention. The relevant evidence is “Device specifications confirm the required usable capacity.”.

B:

Controller/firmware maximums limit usable installed RAM. For the situation described—A field laptop has all memory soldered and no expansion slot, yet an upgrade kit was requested—this would not demonstrate the specified intervention. The relevant evidence is “Device specifications confirm the required usable capacity.”.

C:

ECC needs compatible memory and platform support to correct bit errors. For the situation described—A field laptop has all memory soldered and no expansion slot, yet an upgrade kit was requested—this would not demonstrate the specified intervention. The relevant evidence is “Device specifications confirm the required usable capacity.”.

Question 271

A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types. Which action is MOST appropriate for this situation?

  1. Install a compatible matched second DIMM in the paired slot.
  2. Install supported ECC memory with motherboard/CPU compatibility.
  3. Populate only the documented supported module class and slot configuration.
  4. Use a replacement model or platform with sufficient installed memory.

Explanation

Correct Answer

C:

Registered and unbuffered DIMM support is platform-specific and mixing types is not generally permitted. In this situation—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types—the right response is “Populate only the documented supported module class and slot configuration.”. A confirming result would be “BIOS reports valid channel population without type mismatch.”.

Incorrect Answers

A:

Paired compatible modules can increase memory-channel bandwidth. That does not directly address the condition described—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types. “Populate only the documented supported module class and slot configuration.” is the appropriate response because registered and unbuffered DIMM support is platform-specific and mixing types is not generally permitted.

B:

ECC needs compatible memory and platform support to correct bit errors. That does not directly address the condition described—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types. “Populate only the documented supported module class and slot configuration.” is the appropriate response because registered and unbuffered DIMM support is platform-specific and mixing types is not generally permitted.

D:

Soldered memory cannot be swapped like a socketed SO-DIMM. That does not directly address the condition described—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types. “Populate only the documented supported module class and slot configuration.” is the appropriate response because registered and unbuffered DIMM support is platform-specific and mixing types is not generally permitted.

Question 272

A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware reports dual-channel operation and stability checks pass.
  2. BIOS reports valid channel population without type mismatch.
  3. Firmware reports ECC enabled and diagnostic events are available.
  4. Device specifications confirm the required usable capacity.

Explanation

Correct Answer

B:

Registered and unbuffered DIMM support is platform-specific and mixing types is not generally permitted. The outcome “BIOS reports valid channel population without type mismatch.” verifies the action “Populate only the documented supported module class and slot configuration.” for this situation: A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types.

Incorrect Answers

A:

Paired compatible modules can increase memory-channel bandwidth. For the situation described—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types—this would not demonstrate the specified intervention. The relevant evidence is “BIOS reports valid channel population without type mismatch.”.

C:

ECC needs compatible memory and platform support to correct bit errors. For the situation described—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types—this would not demonstrate the specified intervention. The relevant evidence is “BIOS reports valid channel population without type mismatch.”.

D:

Soldered memory cannot be swapped like a socketed SO-DIMM. For the situation described—A server board reports a memory population warning because the paired channels use dissimilar RDIMM/UDIMM types—this would not demonstrate the specified intervention. The relevant evidence is “BIOS reports valid channel population without type mismatch.”.

Question 273

A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only. Which action is MOST appropriate for this situation?

  1. Inspect the M.2 PCIe slot and retention screw, not SATA cabling.
  2. Install a compatible 2.5-inch SATA SSD.
  3. Install SAS-compatible drives according to the enclosure specification.
  4. Choose an M.2 NVMe device supported by the motherboard slot.

Explanation

Correct Answer

D:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. In this situation—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only—the right response is “Choose an M.2 NVMe device supported by the motherboard slot.”. A confirming result would be “Firmware enumerates the NVMe controller and boots from the selected device.”.

Incorrect Answers

A:

Most motherboard-mounted M.2 NVMe drives use the slot for data and power. That does not directly address the condition described—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only. “Choose an M.2 NVMe device supported by the motherboard slot.” is the appropriate response because m.2 defines form factor; SATA and PCIe/NVMe are distinct protocols.

B:

SATA remains a supported SSD interface independent of NVMe. That does not directly address the condition described—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only. “Choose an M.2 NVMe device supported by the motherboard slot.” is the appropriate response because m.2 defines form factor; SATA and PCIe/NVMe are distinct protocols.

C:

SAS storage targets enterprise controller and connector compatibility. That does not directly address the condition described—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only. “Choose an M.2 NVMe device supported by the motherboard slot.” is the appropriate response because m.2 defines form factor; SATA and PCIe/NVMe are distinct protocols.

Question 274

A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only. After the appropriate change, which observation BEST verifies the intended result?

  1. The controller shows a healthy array after rebuild without data corruption.
  2. The SATA controller detects the drive and its volume passes file tests.
  3. Firmware enumerates the NVMe controller and boots from the selected device.
  4. Restored files pass integrity checks after the array is rebuilt.

Explanation

Correct Answer

C:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. The outcome “Firmware enumerates the NVMe controller and boots from the selected device.” verifies the action “Choose an M.2 NVMe device supported by the motherboard slot.” for this situation: A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only.

Incorrect Answers

A:

RAID 5 generally tolerates one failed disk and rebuilds from distributed parity. For the situation described—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only—this would not demonstrate the specified intervention. The relevant evidence is “Firmware enumerates the NVMe controller and boots from the selected device.”.

B:

SATA remains a supported SSD interface independent of NVMe. For the situation described—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only—this would not demonstrate the specified intervention. The relevant evidence is “Firmware enumerates the NVMe controller and boots from the selected device.”.

D:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. For the situation described—A new desktop wants low-latency NVMe storage, but a chosen M.2 SSD uses SATA protocol and a slot supports PCIe only—this would not demonstrate the specified intervention. The relevant evidence is “Firmware enumerates the NVMe controller and boots from the selected device.”.

Question 275

A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector. Which action is MOST appropriate for this situation?

  1. Inspect the M.2 PCIe slot and retention screw, not SATA cabling.
  2. Choose an M.2 NVMe device supported by the motherboard slot.
  3. Install SAS-compatible drives according to the enclosure specification.
  4. Install a compatible 2.5-inch SATA SSD.

Explanation

Correct Answer

D:

SATA remains a supported SSD interface independent of NVMe. In this situation—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector—the right response is “Install a compatible 2.5-inch SATA SSD.”. A confirming result would be “The SATA controller detects the drive and its volume passes file tests.”.

Incorrect Answers

A:

Most motherboard-mounted M.2 NVMe drives use the slot for data and power. That does not directly address the condition described—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector. “Install a compatible 2.5-inch SATA SSD.” is the appropriate response because sATA remains a supported SSD interface independent of NVMe.

B:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. That does not directly address the condition described—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector. “Install a compatible 2.5-inch SATA SSD.” is the appropriate response because sATA remains a supported SSD interface independent of NVMe.

C:

SAS storage targets enterprise controller and connector compatibility. That does not directly address the condition described—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector. “Install a compatible 2.5-inch SATA SSD.” is the appropriate response because sATA remains a supported SSD interface independent of NVMe.

Question 276

A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware enumerates the NVMe controller and boots from the selected device.
  2. The SATA controller detects the drive and its volume passes file tests.
  3. Firmware lists the NVMe device under PCIe/NVMe storage.
  4. Controller reports striped mirrors and tests survive a permitted single-disk failure.

Explanation

Correct Answer

B:

SATA remains a supported SSD interface independent of NVMe. The outcome “The SATA controller detects the drive and its volume passes file tests.” verifies the action “Install a compatible 2.5-inch SATA SSD.” for this situation: A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector.

Incorrect Answers

A:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. For the situation described—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector—this would not demonstrate the specified intervention. The relevant evidence is “The SATA controller detects the drive and its volume passes file tests.”.

C:

Most motherboard-mounted M.2 NVMe drives use the slot for data and power. For the situation described—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector—this would not demonstrate the specified intervention. The relevant evidence is “The SATA controller detects the drive and its volume passes file tests.”.

D:

RAID 10 stripes mirrored pairs, combining speed and redundancy. For the situation described—A legacy desktop has spare SATA ports but no NVMe-capable M.2 connector—this would not demonstrate the specified intervention. The relevant evidence is “The SATA controller detects the drive and its volume passes file tests.”.

Question 277

An enterprise storage shelf exposes SAS connectors and its controller is SAS-only. Which action is MOST appropriate for this situation?

  1. Install a compatible 2.5-inch SATA SSD.
  2. Install SAS-compatible drives according to the enclosure specification.
  3. Use compatible USB flash storage and verify file integrity.
  4. Choose an M.2 NVMe device supported by the motherboard slot.

Explanation

Correct Answer

B:

SAS storage targets enterprise controller and connector compatibility. In this situation—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only—the right response is “Install SAS-compatible drives according to the enclosure specification.”. A confirming result would be “The RAID controller enumerates all shelf drives.”.

Incorrect Answers

A:

SATA remains a supported SSD interface independent of NVMe. That does not directly address the condition described—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only. “Install SAS-compatible drives according to the enclosure specification.” is the appropriate response because sAS storage targets enterprise controller and connector compatibility.

C:

USB flash provides portable solid-state storage without an optical mechanism. That does not directly address the condition described—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only. “Install SAS-compatible drives according to the enclosure specification.” is the appropriate response because sAS storage targets enterprise controller and connector compatibility.

D:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. That does not directly address the condition described—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only. “Install SAS-compatible drives according to the enclosure specification.” is the appropriate response because sAS storage targets enterprise controller and connector compatibility.

Question 278

An enterprise storage shelf exposes SAS connectors and its controller is SAS-only. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware enumerates the NVMe controller and boots from the selected device.
  2. The RAID controller enumerates all shelf drives.
  3. The controller shows a healthy array after rebuild without data corruption.
  4. The SATA controller detects the drive and its volume passes file tests.

Explanation

Correct Answer

B:

SAS storage targets enterprise controller and connector compatibility. The outcome “The RAID controller enumerates all shelf drives.” verifies the action “Install SAS-compatible drives according to the enclosure specification.” for this situation: An enterprise storage shelf exposes SAS connectors and its controller is SAS-only.

Incorrect Answers

A:

M.2 defines form factor; SATA and PCIe/NVMe are distinct protocols. For the situation described—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only—this would not demonstrate the specified intervention. The relevant evidence is “The RAID controller enumerates all shelf drives.”.

C:

RAID 5 generally tolerates one failed disk and rebuilds from distributed parity. For the situation described—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only—this would not demonstrate the specified intervention. The relevant evidence is “The RAID controller enumerates all shelf drives.”.

D:

SATA remains a supported SSD interface independent of NVMe. For the situation described—An enterprise storage shelf exposes SAS connectors and its controller is SAS-only—this would not demonstrate the specified intervention. The relevant evidence is “The RAID controller enumerates all shelf drives.”.

Question 279

A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up. Which action is MOST appropriate for this situation?

  1. Configure RAID 6 using disks/controller that support dual parity.
  2. Configure RAID 1 mirroring with a proper backup strategy.
  3. Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.
  4. Replace the failed member and allow controlled parity rebuild.

Explanation

Correct Answer

C:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. In this situation—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up—the right response is “Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.”. A confirming result would be “Restored files pass integrity checks after the array is rebuilt.”.

Incorrect Answers

A:

RAID 6 uses dual distributed parity for two-disk failure tolerance. That does not directly address the condition described—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up. “Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.” is the appropriate response because rAID 0 stripes without parity or mirroring and has no single-disk fault tolerance.

B:

RAID 1 keeps a mirror copy on each member, though it is not backup. That does not directly address the condition described—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up. “Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.” is the appropriate response because rAID 0 stripes without parity or mirroring and has no single-disk fault tolerance.

D:

RAID 5 generally tolerates one failed disk and rebuilds from distributed parity. That does not directly address the condition described—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up. “Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.” is the appropriate response because rAID 0 stripes without parity or mirroring and has no single-disk fault tolerance.

Question 280

A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up. After the appropriate change, which observation BEST verifies the intended result?

  1. Restored files pass integrity checks after the array is rebuilt.
  2. A controlled two-member failure simulation remains accessible.
  3. The controller shows a healthy array after rebuild without data corruption.
  4. Unplugging one test member in a controlled maintenance window leaves the array accessible.

Explanation

Correct Answer

A:

RAID 0 stripes without parity or mirroring and has no single-disk fault tolerance. The outcome “Restored files pass integrity checks after the array is rebuilt.” verifies the action “Recover from an independent backup rather than expecting RAID 0 to survive the lost disk.” for this situation: A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up.

Incorrect Answers

B:

RAID 6 uses dual distributed parity for two-disk failure tolerance. For the situation described—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up—this would not demonstrate the specified intervention. The relevant evidence is “Restored files pass integrity checks after the array is rebuilt.”.

C:

RAID 5 generally tolerates one failed disk and rebuilds from distributed parity. For the situation described—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up—this would not demonstrate the specified intervention. The relevant evidence is “Restored files pass integrity checks after the array is rebuilt.”.

D:

RAID 1 keeps a mirror copy on each member, though it is not backup. For the situation described—A two-drive RAID 0 array needs one disk replaced after failure but the data was not backed up—this would not demonstrate the specified intervention. The relevant evidence is “Restored files pass integrity checks after the array is rebuilt.”.