McAfee-Secured Website

Exam Bundle

Exam Code: 200-301

Exam Name Cisco Certified Network Associate (CCNA)

Certification Provider: Cisco

Corresponding Certification: CCNA

Cisco 200-301 Bundle $44.99

100% Cisco 200-301 Guaranteed Success With Testking Training Materials

Get Real 200-301 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    200-301 Questions & Answers

    760 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 200-301 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 200-301 Video Course

    200-301 Video Course

    271 Video Lectures

    200-301 Video Course is developed by Cisco Professionals to help you pass the 200-301 exam.

    Description

    This course will improve your knowledge and skills required to pass Cisco Certified Network Associate (CCNA) exam.
  • Study Guide

    200-301 Study Guide

    1969 PDF Pages

    Developed by industry experts, this 1969-page guide spells out in painstaking detail all of the information you need to ace 200-301 exam.

Cisco Certified Network Associate (CCNA) (200-301) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    760 Questions

    $124.99
  • 200-301 Video Course

    Video Course

    271 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    1969 PDF Pages

    $29.99

Cisco 200-301 Practice Test 4

Question 30

A modern full-duplex Ethernet segment has only a single switch and router directly connected, with no hub. Which media relationship best describes it?

  1. A point-to-point Ethernet link
  2. Single-mode optical fiber
  3. Twisted-pair copper Ethernet cable
  4. Multimode optical fiber

Explanation

Correct Answer

A:

The Ethernet data link is point-to-point between two active ports, irrespective of physical cable material.

Incorrect Answers

B:

Single-mode fiber uses a narrow core for long optical spans, typically with laser transceivers.

C:

Copper twisted pair is appropriate for standard electrical Ethernet ports and short horizontal runs.

D:

Multimode fiber uses a wider core and is suitable for shorter links with compatible optics.

Question 31

A building-to-building connection is too long for the supported multimode optics and copper maximum cable length. Which medium is best for the replacement design?

  1. Single-mode optical fiber
  2. Twisted-pair copper Ethernet cable
  3. Multimode optical fiber
  4. Direct-attach copper cable

Explanation

Correct Answer

A:

Long-reach single-mode optics can support spans beyond short copper and multimode distances.

Incorrect Answers

B:

Copper twisted pair is appropriate for standard electrical Ethernet ports and short horizontal runs.

C:

Multimode fiber uses a wider core and is suitable for shorter links with compatible optics.

D:

DAC cables link supported closely adjacent SFP-type ports over short distances.

Question 32

The cable specification requires carrying 802.3 Power over Ethernet to an IP camera. Which physical medium supports the electrical power feed?

  1. Twisted-pair copper Ethernet cable
  2. Multimode optical fiber
  3. Single-mode optical fiber
  4. A point-to-point Ethernet link

Explanation

Correct Answer

A:

PoE is delivered over compatible twisted-pair copper conductors, not ordinary glass fiber.

Incorrect Answers

B:

Multimode fiber uses a wider core and is suitable for shorter links with compatible optics.

C:

Single-mode fiber uses a narrow core for long optical spans, typically with laser transceivers.

D:

Point-to-point links have a dedicated pair of link partners rather than a shared collision medium.

Question 33

A switch uses a multimode SR optic but the patch-panel cable is single-mode fiber. Which design element should be verified first?

  1. Direct-attach copper cable
  2. An optics module matching speed, wavelength and fiber type
  3. A point-to-point Ethernet link
  4. Twisted-pair copper Ethernet cable

Explanation

Correct Answer

B:

Optic wavelength and intended fiber type must match the installed medium and partner.

Incorrect Answers

A:

DAC cables link supported closely adjacent SFP-type ports over short distances.

C:

Point-to-point links have a dedicated pair of link partners rather than a shared collision medium.

D:

Copper twisted pair is appropriate for standard electrical Ethernet ports and short horizontal runs.

Question 34

An engineer selects long-haul optics for a remote industrial site and must minimize loss over a multi-kilometer run. Which fiber family is the usual choice?

  1. Single-mode optical fiber
  2. Multimode optical fiber
  3. Direct-attach copper cable
  4. Twisted-pair copper Ethernet cable

Explanation

Correct Answer

A:

Single-mode fiber is the conventional medium for extended-distance optical transmission.

Incorrect Answers

B:

Multimode fiber uses a wider core and is suitable for shorter links with compatible optics.

C:

DAC cables link supported closely adjacent SFP-type ports over short distances.

D:

Copper twisted pair is appropriate for standard electrical Ethernet ports and short horizontal runs.

Question 35

A standard 1000BASE-T interface on a network printer must connect to a copper LAN switch 15 meters away. Which media should be used?

  1. Direct-attach copper cable
  2. Twisted-pair copper Ethernet cable
  3. Multimode optical fiber
  4. Single-mode optical fiber

Explanation

Correct Answer

B:

An RJ-45 1000BASE-T port is intended for suitable four-pair twisted-pair cable.

Incorrect Answers

A:

DAC cables link supported closely adjacent SFP-type ports over short distances.

C:

Multimode fiber uses a wider core and is suitable for shorter links with compatible optics.

D:

Single-mode fiber uses a narrow core for long optical spans, typically with laser transceivers.

Question 36

A data center switch port is SFP28 but the matching 25-Gbps optic at the far end is designed for short-reach multimode runs. Which physical cabling type should the installer plan?

  1. Direct-attach copper cable
  2. Single-mode optical fiber
  3. Twisted-pair copper Ethernet cable
  4. Multimode optical fiber

Explanation

Correct Answer

D:

Short-range multimode optics require their specified multimode fiber plant.

Incorrect Answers

A:

DAC cables link supported closely adjacent SFP-type ports over short distances.

B:

Single-mode fiber uses a narrow core for long optical spans, typically with laser transceivers.

C:

Copper twisted pair is appropriate for standard electrical Ethernet ports and short horizontal runs.

Question 37

A new optical Ethernet link uses an 850-nm short-reach optic on one switch, while its peer has a long-reach transceiver designed for a different wavelength and fiber type. The link remains down. Which design element must be made compatible at both ends?

  1. An optics module matching speed, wavelength and fiber type
  2. Direct-attach copper cable
  3. A point-to-point Ethernet link
  4. Twisted-pair copper Ethernet cable

Explanation

Correct Answer

A:

The transceivers must use compatible speed, optical wavelength and specified single-mode or multimode fiber characteristics at each endpoint.

Incorrect Answers

B:

A DAC assembly replaces optical modules for supported short copper interconnects; it cannot make the mismatched installed optics interoperate.

C:

The physical link is already point-to-point; that topology says nothing about whether the optical wavelengths match.

D:

RJ-45 twisted-pair Ethernet copper cannot repair incompatibility between the two selected optical transceivers.

Question 38

An older 100-Mbps link has one side forced full duplex and the other half duplex. Small pings work but transfers show collisions and sluggish performance. What should be corrected?

  1. Inspect damaged cabling and physical signal integrity for CRC/FCS errors
  2. Issue no shutdown on the administratively disabled interface
  3. Inspect and correct a duplex mismatch between the Ethernet peers
  4. Match the link partners to a common supported speed and negotiation mode

Explanation

Correct Answer

C:

Both link partners need compatible duplex settings to eliminate the duplex mismatch.

Incorrect Answers

A:

The evidence is collision-like performance loss after the two peers were forced to different duplex modes, not a physical fault identified by persistent FCS errors. Test the actual negotiated/forced duplex at each end.

B:

Neither interface is described as administratively shut; `no shutdown` cannot reconcile one peer at half duplex with the other at full duplex.

D:

Both ends are already operating at 100 Mb/s. Equal speed alone cannot resolve their opposing duplex settings or late-collision symptoms.

Question 39

A copper uplink shows steadily increasing FCS errors whenever an industrial motor runs, but interface speed is negotiated correctly. What should be investigated?

  1. Inspect damaged cabling and physical signal integrity for CRC/FCS errors
  2. Verify path MTU and fragmentation or PMTUD behavior
  3. Issue no shutdown on the administratively disabled interface
  4. Match the link partners to a common supported speed and negotiation mode

Explanation

Correct Answer

A:

Interference or defective physical cabling can corrupt Ethernet frames and increase FCS errors.

Incorrect Answers

B:

MTU problems typically correlate with packet size or DF/path-MTU behavior, whereas errors rise specifically when the motor introduces electrical interference onto the copper run.

C:

The copper uplink is passing frames and accumulating CRC errors, so an administratively disabled interface is inconsistent with the observation.

D:

Correct speed negotiation is already established. The motor-correlated FCS failures direct the investigation to shielding, routing and cable integrity instead.

Question 40

A switch interface remains down after a server card is hard-set to an unsupported rate, while autonegotiation is disabled on the peer. What settings need attention?

  1. Inspect and correct a duplex mismatch between the Ethernet peers
  2. Match the link partners to a common supported speed and negotiation mode
  3. Verify path MTU and fragmentation or PMTUD behavior
  4. Inspect damaged cabling and physical signal integrity for CRC/FCS errors

Explanation

Correct Answer

B:

The ports must agree on a supported physical line rate and negotiation combination.

Incorrect Answers

A:

A duplex mismatch can degrade throughput on an established link, but the immediate problem here is a peer forced to a data rate that the other side cannot support.

C:

A path-MTU fault would affect oversized frames after link establishment. Here carrier does not form because link partner speed capabilities disagree.

D:

The stated failure follows an unsupported forced rate; checking physical cabling only becomes relevant if compatible speed/negotiation settings still cannot establish carrier.