McAfee-Secured Website

Exam Code: 4A0-D01

Exam Name: Nokia Data Center Fabric Fundamentals

Certification Provider: Nokia

100% Nokia 4A0-D01 Guaranteed Success With Testking Training Materials

Get Real 4A0-D01 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

61 Questions & Answers with Testing Engine

"Nokia Data Center Fabric Fundamentals Exam", also known as 4A0-D01 exam, is a Nokia certification exam.

Pass your tests with the always up-to-date 4A0-D01 Exam Engine. Your 4A0-D01 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

Nokia 4A0-D01 Practice Test 20

Question 190

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, the data center fabric team observes: A CLI command displays a long output and the engineer misses the failed interface line. Which evidence directly validates the intended repair?

  1. The structured query returns the target interface and its actual operational status without truncation
  2. The running configuration includes the intended change and the affected interface or route state updates
  3. A subsequent state read shows the intended committed configuration and effect
  4. Tagged and untagged test frames enter their designated network instances

Explanation

Correct Answer

A:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this result is the relevant closure evidence: The structured query returns the target interface and its actual operational status without truncation. It checks the effect of: Use supported SR Linux CLI filtering or JSON output to isolate matching interface state. The underlying issue was: The diagnostic session lacks filtering or structured output for the relevant field.

Incorrect Answers

B:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: The running configuration includes the intended change and the affected interface or route state updates. This option assumes the other problem (An operator edits SR Linux candidate configuration but sees no change in live forwarding) is present. The case instead describes A CLI command displays a long output and the engineer misses the failed interface line, for which the causal issue is The diagnostic session lacks filtering or structured output for the relevant field.

C:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: A subsequent state read shows the intended committed configuration and effect. It tests a different symptom: An API client repeatedly sends configuration changes but the switch does not reflect them. For the observed case, the relevant distinction is The diagnostic session lacks filtering or structured output for the relevant field, with verification: The structured query returns the target interface and its actual operational status without truncation.

D:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: Tagged and untagged test frames enter their designated network instances. The option describes a different failure mode: A native untagged frame is unexpectedly treated as a tagged tenant service. It would address The subinterface classification is configured for the wrong tagged or untagged traffic type, but here the case reports A CLI command displays a long output and the engineer misses the failed interface line. The current required evidence is: The structured query returns the target interface and its actual operational status without truncation.

Question 191

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, the data center fabric team observes: A CLI command displays a long output and the engineer misses the failed interface line. Which underlying mechanism best accounts for this symptom?

  1. The fault is in the physical link or transceiver rather than solely in routing policy
  2. The diagnostic session lacks filtering or structured output for the relevant field
  3. The 802.1Q VLAN tag mapping does not match the configured subinterface encapsulation
  4. The configuration was staged in a candidate datastore without a committed activation

Explanation

Correct Answer

B:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, the specific mechanism is: The diagnostic session lacks filtering or structured output for the relevant field. It explains the reported state: A CLI command displays a long output and the engineer misses the failed interface line. The targeted corrective action is: Use supported SR Linux CLI filtering or JSON output to isolate matching interface state.

Incorrect Answers

A:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: The fault is in the physical link or transceiver rather than solely in routing policy. This option assumes the other problem (A high-speed interface shows rapidly increasing errors while routing sessions still intermittently recover) is present. The case instead describes A CLI command displays a long output and the engineer misses the failed interface line, for which the causal issue is The diagnostic session lacks filtering or structured output for the relevant field.

C:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: The 802.1Q VLAN tag mapping does not match the configured subinterface encapsulation. The option describes a different failure mode: A tagged server VLAN arrives on a leaf but no corresponding SR Linux subinterface receives frames. It would address The 802.1Q VLAN tag mapping does not match the configured subinterface encapsulation, but here the case reports A CLI command displays a long output and the engineer misses the failed interface line. The current required evidence is: The structured query returns the target interface and its actual operational status without truncation.

D:

An operator edits SR Linux candidate configuration but sees no change in live forwarding. Here, the diagnostic session lacks filtering or structured output for the relevant field.

Question 192

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, the data center fabric team observes: A CLI command displays a long output and the engineer misses the failed interface line. Which review gate should be added to prevent the same error?

  1. Standardize filtered state queries for repeated fabric diagnostics
  2. Check interface admin state during turn-up acceptance
  3. Require both instance creation and attachment evidence during deployment
  4. Cross-check VLAN-to-MAC-VRF mapping during tenant activation

Explanation

Correct Answer

A:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, the preventive control is: Standardize filtered state queries for repeated fabric diagnostics. It catches the same mechanism (The diagnostic session lacks filtering or structured output for the relevant field) before the symptom recurs. An appropriate regression observation is: The structured query returns the target interface and its actual operational status without truncation.

Incorrect Answers

B:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: Check interface admin state during turn-up acceptance. The option describes a different failure mode: A new network interface is administratively disabled although optics and cabling are healthy. It would address The interface is not enabled in the applicable SR Linux configuration, but here the case reports A CLI command displays a long output and the engineer misses the failed interface line. The current required evidence is: The structured query returns the target interface and its actual operational status without truncation.

C:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: Require both instance creation and attachment evidence during deployment. That choice would be more relevant when this different symptom occurs: A configured network instance is present but has no usable attached interfaces. The present scenario instead points to: The diagnostic session lacks filtering or structured output for the relevant field. The correct resolution has its own verification outcome: The structured query returns the target interface and its actual operational status without truncation.

D:

At Woodcrest Rail Logistics, while committing an SR Linux configuration change, this option proposes: Cross-check VLAN-to-MAC-VRF mapping during tenant activation. This is a valid category of fabric maintenance for another scenario (MAC learning occurs in one MAC-VRF while a server belongs to another tenant), not the targeted action for Woodcrest Rail Logistics. The distinction is the actual cause: The diagnostic session lacks filtering or structured output for the relevant field.

Question 193

At Oakline Health Systems, while reviewing interface counters, the data center fabric team observes: An SR Linux configuration commit is rejected but the engineer assumes the failed change is active. What configuration or operational change should the engineer prioritize?

  1. Correct the interface hierarchy and apply the intended Layer 3 address to the approved subinterface
  2. Investigate attachment topology and apply supported MAC-move controls without globally suppressing learning
  3. Read the commit failure details, fix the invalid model fields and commit an approved valid change
  4. Check supported optics, lane settings, cabling and peer configuration before changing routing

Explanation

Correct Answer

C:

At Oakline Health Systems, while reviewing interface counters, choose this remediation because it targets the mechanism: The candidate change did not pass required schema or configuration validation. The supported corrective action is: Read the commit failure details, fix the invalid model fields and commit an approved valid change. Verification requires: The CLI reports a successful commit and the running datastore reflects the correction.

Incorrect Answers

A:

A routed port is configured with an IP address under an unexpected subinterface context. Here, the candidate change did not pass required schema or configuration validation.

B:

At Oakline Health Systems, while reviewing interface counters, this option proposes: Investigate attachment topology and apply supported MAC-move controls without globally suppressing learning. This is a valid category of fabric maintenance for another scenario (A device reports repeated MAC moves between two attachment points during a suspected Layer 2 loop), not the targeted action for Oakline Health Systems. The distinction is the actual cause: The candidate change did not pass required schema or configuration validation.

D:

At Oakline Health Systems, while reviewing interface counters, this option proposes: Check supported optics, lane settings, cabling and peer configuration before changing routing. Using that approach would investigate A 100G uplink remains down after an optics swap despite a valid peer port instead. No evidence for that separate failure is supplied here; the reported case is consistent with: The candidate change did not pass required schema or configuration validation.

Question 194

At Oakline Health Systems, while reviewing interface counters, the data center fabric team observes: An SR Linux configuration commit is rejected but the engineer assumes the failed change is active. What test result proves the affected fabric function now works?

  1. The CLI reports a successful commit and the running datastore reflects the correction
  2. The intended service learns the test MAC while other MAC-VRF tables remain unchanged
  3. A controlled IPv6 path succeeds through the correct network instance
  4. Only the affected subinterface shows the relevant error or traffic delta

Explanation

Correct Answer

A:

At Oakline Health Systems, while reviewing interface counters, this result is the relevant closure evidence: The CLI reports a successful commit and the running datastore reflects the correction. It checks the effect of: Read the commit failure details, fix the invalid model fields and commit an approved valid change. The underlying issue was: The candidate change did not pass required schema or configuration validation.

Incorrect Answers

B:

At Oakline Health Systems, while reviewing interface counters, this option proposes: The intended service learns the test MAC while other MAC-VRF tables remain unchanged. Although related to SR Linux CLI, model configuration and interfaces, the proposed change fits another mechanism: The bridge subinterface was attached to the wrong MAC-VRF service context. The evidence in the current case requires a different result: The CLI reports a successful commit and the running datastore reflects the correction.

C:

At Oakline Health Systems, while reviewing interface counters, this option proposes: A controlled IPv6 path succeeds through the correct network instance. Using that approach would investigate A service has healthy IPv4 reachability but its IPv6 traffic fails due to missing local addressing instead. No evidence for that separate failure is supplied here; the reported case is consistent with: The candidate change did not pass required schema or configuration validation.

D:

At Oakline Health Systems, while reviewing interface counters, this option proposes: Only the affected subinterface shows the relevant error or traffic delta. The alternative focuses on The monitoring system measures only parent port counters when per-subinterface visibility is needed, not on the stated defect. For this scenario the expected acceptance result would be: The CLI reports a successful commit and the running datastore reflects the correction.

Question 195

At Oakline Health Systems, while reviewing interface counters, the data center fabric team observes: An SR Linux configuration commit is rejected but the engineer assumes the failed change is active. What specific misconfiguration or design error is most likely?

  1. The integration assumes display column positions are a stable machine-readable interface
  2. A broad CLI match filter excludes dependent configuration or state fields
  3. The monitoring system measures only parent port counters when per-subinterface visibility is needed
  4. The candidate change did not pass required schema or configuration validation

Explanation

Correct Answer

D:

At Oakline Health Systems, while reviewing interface counters, the candidate change did not pass required schema or configuration validation. That is the cause of the described failure, and a corrective check should demonstrate: The CLI reports a successful commit and the running datastore reflects the correction.

Incorrect Answers

A:

At Oakline Health Systems, while reviewing interface counters, this option proposes: The integration assumes display column positions are a stable machine-readable interface. Although related to SR Linux CLI, model configuration and interfaces, the proposed change fits another mechanism: The integration assumes display column positions are a stable machine-readable interface. The evidence in the current case requires a different result: The CLI reports a successful commit and the running datastore reflects the correction.

B:

At Oakline Health Systems, while reviewing interface counters, this option proposes: A broad CLI match filter excludes dependent configuration or state fields. Using that approach would investigate A management query returns incomplete output because an operator filters out relevant configuration branches instead. No evidence for that separate failure is supplied here; the reported case is consistent with: The candidate change did not pass required schema or configuration validation.

C:

At Oakline Health Systems, while reviewing interface counters, this option proposes: The monitoring system measures only parent port counters when per-subinterface visibility is needed. The alternative focuses on The monitoring system measures only parent port counters when per-subinterface visibility is needed, not on the stated defect. For this scenario the expected acceptance result would be: The CLI reports a successful commit and the running datastore reflects the correction.

Question 196

At Oakline Health Systems, while reviewing interface counters, the data center fabric team observes: An SR Linux configuration commit is rejected but the engineer assumes the failed change is active. What repeatable acceptance check would reduce recurrence?

  1. Treat commit success as a separate acceptance gate from successful typing
  2. Inspect full interface paths when reviewing routed interface changes
  3. Maintain both physical and logical interface visibility in fabric monitoring
  4. Alert on abnormal MAC-move events while reviewing multi-homing designs

Explanation

Correct Answer

A:

At Oakline Health Systems, while reviewing interface counters, the preventive control is: Treat commit success as a separate acceptance gate from successful typing. It catches the same mechanism (The candidate change did not pass required schema or configuration validation) before the symptom recurs. An appropriate regression observation is: The CLI reports a successful commit and the running datastore reflects the correction.

Incorrect Answers

B:

At Oakline Health Systems, while reviewing interface counters, this option proposes: Inspect full interface paths when reviewing routed interface changes. The alternative focuses on The IP addressing change was attached to the wrong interface or subinterface scope, not on the stated defect. For this scenario the expected acceptance result would be: The CLI reports a successful commit and the running datastore reflects the correction.

C:

At Oakline Health Systems, while reviewing interface counters, this option proposes: Maintain both physical and logical interface visibility in fabric monitoring. This option assumes the other problem (An interface statistics report aggregates multiple subinterfaces and hides the affected VLAN) is present. The case instead describes An SR Linux configuration commit is rejected but the engineer assumes the failed change is active, for which the causal issue is The candidate change did not pass required schema or configuration validation.

D:

At Oakline Health Systems, while reviewing interface counters, this option proposes: Alert on abnormal MAC-move events while reviewing multi-homing designs. It tests a different symptom: A device reports repeated MAC moves between two attachment points during a suspected Layer 2 loop. For the observed case, the relevant distinction is The candidate change did not pass required schema or configuration validation, with verification: The CLI reports a successful commit and the running datastore reflects the correction.

Question 197

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, the data center fabric team observes: A fabric team applies a new interface description to the wrong port after a chassis replacement. Which action resolves the identified fabric-management issue?

  1. Validate the installed port inventory and update the configuration target to the actual new interface
  2. Set and verify required execution context explicitly or use a self-contained model path
  3. Inspect instance bindings and service dependencies then migrate them before deleting the subinterface
  4. Read the commit failure details, fix the invalid model fields and commit an approved valid change

Explanation

Correct Answer

A:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, validate the installed port inventory and update the configuration target to the actual new interface. This addresses the specific failure mechanism (The old physical port mapping was reused without reconciling current interface identifiers) rather than treating only the visible alarm. The required acceptance evidence is: The intended port displays the approved description and the neighbor mapping is correct.

Incorrect Answers

B:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Set and verify required execution context explicitly or use a self-contained model path. It tests a different symptom: A script relies on an environment variable that is unset in automated CLI sessions. For the observed case, the relevant distinction is The old physical port mapping was reused without reconciling current interface identifiers, with verification: The intended port displays the approved description and the neighbor mapping is correct.

C:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Inspect instance bindings and service dependencies then migrate them before deleting the subinterface. The option describes a different failure mode: An operator deletes an SR Linux subinterface that still carries an active tenant service. It would address Dependency checks were skipped before removing a network resource, but here the case reports A fabric team applies a new interface description to the wrong port after a chassis replacement. The current required evidence is: The intended port displays the approved description and the neighbor mapping is correct.

D:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Read the commit failure details, fix the invalid model fields and commit an approved valid change. That choice would be more relevant when this different symptom occurs: An SR Linux configuration commit is rejected but the engineer assumes the failed change is active. The present scenario instead points to: The old physical port mapping was reused without reconciling current interface identifiers. The correct resolution has its own verification outcome: The intended port displays the approved description and the neighbor mapping is correct.

Question 198

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, the data center fabric team observes: A fabric team applies a new interface description to the wrong port after a chassis replacement. Which result would establish that the original defect has been corrected?

  1. The intended port displays the approved description and the neighbor mapping is correct
  2. The report includes both the intended setting and relevant dependent operational state
  3. The automated query succeeds in fresh sessions without hidden interactive state
  4. Traffic sourced in the tenant VRF follows its own lookup table without appearing in unrelated VRFs

Explanation

Correct Answer

A:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this result is the relevant closure evidence: The intended port displays the approved description and the neighbor mapping is correct. It checks the effect of: Validate the installed port inventory and update the configuration target to the actual new interface. The underlying issue was: The old physical port mapping was reused without reconciling current interface identifiers.

Incorrect Answers

B:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: The report includes both the intended setting and relevant dependent operational state. The option describes a different failure mode: A management query returns incomplete output because an operator filters out relevant configuration branches. It would address A broad CLI match filter excludes dependent configuration or state fields, but here the case reports A fabric team applies a new interface description to the wrong port after a chassis replacement. The current required evidence is: The intended port displays the approved description and the neighbor mapping is correct.

C:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: The automated query succeeds in fresh sessions without hidden interactive state. That choice would be more relevant when this different symptom occurs: A script relies on an environment variable that is unset in automated CLI sessions. The present scenario instead points to: The old physical port mapping was reused without reconciling current interface identifiers. The correct resolution has its own verification outcome: The intended port displays the approved description and the neighbor mapping is correct.

D:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Traffic sourced in the tenant VRF follows its own lookup table without appearing in unrelated VRFs. This is a valid category of fabric maintenance for another scenario (An engineer places an IP interface in a default network instance instead of the assigned tenant VRF), not the targeted action for Parkhaven Rail Logistics. The distinction is the actual cause: The old physical port mapping was reused without reconciling current interface identifiers.

Question 199

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, the data center fabric team observes: A fabric team applies a new interface description to the wrong port after a chassis replacement. Which root cause fits the reported state?

  1. The old physical port mapping was reused without reconciling current interface identifiers
  2. The interface-to-network-instance binding does not follow the tenancy design
  3. The intended SR Linux CLI is YANG model-driven and has a different configuration hierarchy
  4. The diagnostic omits the selected network instance during route lookup

Explanation

Correct Answer

A:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, for Parkhaven Rail Logistics, investigate this cause first: The old physical port mapping was reused without reconciling current interface identifiers. It is directly linked to the observed symptom rather than another service issue.

Incorrect Answers

B:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: The interface-to-network-instance binding does not follow the tenancy design. That choice would be more relevant when this different symptom occurs: An engineer places an IP interface in a default network instance instead of the assigned tenant VRF. The present scenario instead points to: The old physical port mapping was reused without reconciling current interface identifiers. The correct resolution has its own verification outcome: The intended port displays the approved description and the neighbor mapping is correct.

C:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: The intended SR Linux CLI is YANG model-driven and has a different configuration hierarchy. This is a valid category of fabric maintenance for another scenario (A junior operator tries to use a command copied from a different network operating system), not the targeted action for Parkhaven Rail Logistics. The distinction is the actual cause: The old physical port mapping was reused without reconciling current interface identifiers.

D:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: The diagnostic omits the selected network instance during route lookup. Although related to SR Linux CLI, model configuration and interfaces, the proposed change fits another mechanism: The diagnostic omits the selected network instance during route lookup. The evidence in the current case requires a different result: The intended port displays the approved description and the neighbor mapping is correct.

Question 200

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, the data center fabric team observes: A fabric team applies a new interface description to the wrong port after a chassis replacement. Which recurring validation best prevents this failure mode?

  1. Include routing-instance names in troubleshooting artifacts
  2. Update physical-to-logical interface mappings after hardware changes
  3. Test dual-stack families independently on every service turn-up
  4. Separate operator shell conveniences from device configuration policy

Explanation

Correct Answer

B:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, update physical-to-logical interface mappings after hardware changes. This ongoing review specifically addresses: The old physical port mapping was reused without reconciling current interface identifiers. It should remain part of change acceptance, not only incident closure.

Incorrect Answers

A:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Include routing-instance names in troubleshooting artifacts. That choice would be more relevant when this different symptom occurs: An operator inspects an IPv4 route in a tenant instance but checks the default IPv4 table. The present scenario instead points to: The old physical port mapping was reused without reconciling current interface identifiers. The correct resolution has its own verification outcome: The intended port displays the approved description and the neighbor mapping is correct.

C:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Test dual-stack families independently on every service turn-up. Although related to SR Linux CLI, model configuration and interfaces, the proposed change fits another mechanism: The subinterface or IP-VRF lacks the intended IPv6 address or route information. The evidence in the current case requires a different result: The intended port displays the approved description and the neighbor mapping is correct.

D:

At Parkhaven Rail Logistics, while auditing the model-driven CLI hierarchy, this option proposes: Separate operator shell conveniences from device configuration policy. Using that approach would investigate An engineer expects a CLI alias to change the persistent device configuration instead. No evidence for that separate failure is supplied here; the reported case is consistent with: The old physical port mapping was reused without reconciling current interface identifiers.

Nokia Data Center Fabric Fundamentals (4A0-D01) Practice Tests