Question 70
The ONTAP administrators at Linden Manufacturing are responsible for factory CAD datasets and ERP volumes. Their assessment shows: A cluster expansion adds nodes but never validates switch ports, cluster LIF connectivity or software compatibility. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?
Explanation
Correct Answer
New nodes join the cluster with healthy cluster interfaces and eligible storage resources. The observation verifies that the chosen action (Check cluster switch readiness, node compatibility and cluster network membership before adding the pair) has corrected the initiating failure (A cluster expansion adds nodes but never validates switch ports, cluster LIF connectivity or software compatibility). This is directly measurable for Linden Manufacturing's factory CAD datasets and ERP volumes rather than merely reporting task completion.
Incorrect Answers
Client I/O stays within the service threshold throughout an approved staged upgrade rehearsal. This is a valid test for another condition (An administrator upgrades all nodes simultaneously even though the environment requires nondisruptive data access during service) after a different correction (Use the supported rolling automated nondisruptive upgrade method appropriate to the cluster topology). It does not establish the necessary result for Linden Manufacturing's factory CAD datasets and ERP volumes: New nodes join the cluster with healthy cluster interfaces and eligible storage resources.
The planned release and intermediate steps pass compatibility checks and the pre-upgrade health assessment. This is a valid test for another condition (An ONTAP upgrade begins without checking the upgrade path and target release support for the controller model) after a different correction (Review the NetApp-supported upgrade path, prerequisites and platform compatibility before scheduling the change). It does not establish the necessary result for Linden Manufacturing's factory CAD datasets and ERP volumes: New nodes join the cluster with healthy cluster interfaces and eligible storage resources.
Representative clients reconnect and complete I/O on the target release in the supported test environment. This is a valid test for another condition (A service team upgrades ONTAP without verifying application protocol compatibility across the new release) after a different correction (Compare host compatibility and required SMB, NFS and SAN features against the target release and interoperability matrix). It does not establish the necessary result for Linden Manufacturing's factory CAD datasets and ERP volumes: New nodes join the cluster with healthy cluster interfaces and eligible storage resources.