McAfee-Secured Website

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

100% Network Appliance NS0-165 Guaranteed Success With Testking Training Materials

Get Real NS0-165 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

60 Questions & Answers with Testing Engine

"NetApp Certified Data Administrator, ONTAP Exam", also known as NS0-165 exam, is a Network Appliance certification exam.

Pass your tests with the always up-to-date NS0-165 Exam Engine. Your NS0-165 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 33

Question 320

For Northshore Hospitality, a proposed storage change affects guest operations data and reservation reports. The identified control failure is: An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. One target path can be interrupted while I/O continues over the surviving healthy path.
  2. Large packet connectivity tests pass without fragmentation or loss on the production path.
  3. Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.
  4. A routed client and storage LIF exchange traffic symmetrically with no wrong-gateway replies.

Explanation

Correct Answer

A:

One target path can be interrupted while I/O continues over the surviving healthy path. The observation verifies that the chosen action (Validate supported host MPIO and separate target network paths to the ONTAP SVM) has corrected the initiating failure (An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path). This is directly measurable for Northshore Hospitality's guest operations data and reservation reports rather than merely reporting task completion.

Incorrect Answers

B:

Large packet connectivity tests pass without fragmentation or loss on the production path. This is a valid test for another condition (A storage network shows intermittent packet loss after enabling a jumbo MTU on only some devices) after a different correction (Align end-to-end MTU or revert to a consistently supported size across the entire path). It does not establish the necessary result for Northshore Hospitality's guest operations data and reservation reports: One target path can be interrupted while I/O continues over the surviving healthy path.

C:

Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot. This is a valid test for another condition (A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected) after a different correction (Examine cluster network membership, switch configuration and inter-node connectivity independently of client data). It does not establish the necessary result for Northshore Hospitality's guest operations data and reservation reports: One target path can be interrupted while I/O continues over the surviving healthy path.

D:

A routed client and storage LIF exchange traffic symmetrically with no wrong-gateway replies. This is a valid test for another condition (Only clients behind a new router cannot access SVM IP addresses because no return route is configured) after a different correction (Inspect the SVM routing table and configure the missing network or default route). It does not establish the necessary result for Northshore Hospitality's guest operations data and reservation reports: One target path can be interrupted while I/O continues over the surviving healthy path.

Question 321

At Eastport Research Hospital, the production environment supports imaging file shares and patient databases with separately managed development and production resources. Investigators find: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. Which administrative action BEST addresses the specific problem?

  1. Review LIF current port, home port, broadcast domain and failover-group membership.
  2. Inspect interface error counters, switch port health and cabling before changing ONTAP performance policies.
  3. Modify the correct ONTAP logical interface through supported network commands and validate its serving SVM.
  4. Check LIF status, VLAN mapping, routing and intermediate ACLs before changing protocol authorization.

Explanation

Correct Answer

B:

Inspect interface error counters, switch port health and cabling before changing ONTAP performance policies. This action addresses the specific failure: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. For Eastport Research Hospital's imaging file shares and patient databases, a successful implementation should produce the following evidence: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Incorrect Answers

A:

Review LIF current port, home port, broadcast domain and failover-group membership. That approach targets a different ONTAP condition: An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain. At Eastport Research Hospital, for imaging file shares and patient databases, the actual failure is: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. That alternative by itself would not prove the needed outcome: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

C:

Modify the correct ONTAP logical interface through supported network commands and validate its serving SVM. That approach targets a different ONTAP condition: An administrator changes a physical port IP address instead of the protocol-serving LIF and disrupts the intended SVM endpoint. At Eastport Research Hospital, for imaging file shares and patient databases, the actual failure is: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. That alternative by itself would not prove the needed outcome: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

D:

Check LIF status, VLAN mapping, routing and intermediate ACLs before changing protocol authorization. That approach targets a different ONTAP condition: A NAS mount times out from only one subnet and technicians immediately change NFS export policies without testing network reachability. At Eastport Research Hospital, for imaging file shares and patient databases, the actual failure is: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. That alternative by itself would not prove the needed outcome: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Question 322

At Eastport Research Hospital, the production environment supports imaging file shares and patient databases with separately managed development and production resources. Investigators find: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. The intended logical endpoint has the approved address and existing unrelated LIFs are unchanged.
  2. Counters stop increasing after the affected physical link is corrected and throughput stabilizes.
  3. The LIF returns to an appropriate port and client traffic reaches the required VLAN.
  4. A packet path test identifies the blocked hop and the corrected route restores the mount attempt.

Explanation

Correct Answer

B:

Counters stop increasing after the affected physical link is corrected and throughput stabilizes. The observation verifies that the chosen action (Inspect interface error counters, switch port health and cabling before changing ONTAP performance policies) has corrected the initiating failure (A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers). This is directly measurable for Eastport Research Hospital's imaging file shares and patient databases rather than merely reporting task completion.

Incorrect Answers

A:

The intended logical endpoint has the approved address and existing unrelated LIFs are unchanged. This is a valid test for another condition (An administrator changes a physical port IP address instead of the protocol-serving LIF and disrupts the intended SVM endpoint) after a different correction (Modify the correct ONTAP logical interface through supported network commands and validate its serving SVM). It does not establish the necessary result for Eastport Research Hospital's imaging file shares and patient databases: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

C:

The LIF returns to an appropriate port and client traffic reaches the required VLAN. This is a valid test for another condition (An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain) after a different correction (Review LIF current port, home port, broadcast domain and failover-group membership). It does not establish the necessary result for Eastport Research Hospital's imaging file shares and patient databases: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

D:

A packet path test identifies the blocked hop and the corrected route restores the mount attempt. This is a valid test for another condition (A NAS mount times out from only one subnet and technicians immediately change NFS export policies without testing network reachability) after a different correction (Check LIF status, VLAN mapping, routing and intermediate ACLs before changing protocol authorization). It does not establish the necessary result for Eastport Research Hospital's imaging file shares and patient databases: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Question 323

During a routine health assessment at Boreal Foods, the ONTAP administrators find the following ONTAP problem: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. Which administrative action BEST addresses the specific problem?

  1. Check LIF status, VLAN mapping, routing and intermediate ACLs before changing protocol authorization.
  2. Review LIF current port, home port, broadcast domain and failover-group membership.
  3. Modify the correct ONTAP logical interface through supported network commands and validate its serving SVM.
  4. Inspect interface error counters, switch port health and cabling before changing ONTAP performance policies.

Explanation

Correct Answer

D:

Inspect interface error counters, switch port health and cabling before changing ONTAP performance policies. This action addresses the specific failure: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. For Boreal Foods's production inventory files and reporting LUNs, a successful implementation should produce the following evidence: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Incorrect Answers

A:

Check LIF status, VLAN mapping, routing and intermediate ACLs before changing protocol authorization. That approach targets a different ONTAP condition: A NAS mount times out from only one subnet and technicians immediately change NFS export policies without testing network reachability. At Boreal Foods, for production inventory files and reporting LUNs, the actual failure is: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. That alternative by itself would not prove the needed outcome: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

B:

Review LIF current port, home port, broadcast domain and failover-group membership. That approach targets a different ONTAP condition: An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain. At Boreal Foods, for production inventory files and reporting LUNs, the actual failure is: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. That alternative by itself would not prove the needed outcome: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

C:

Modify the correct ONTAP logical interface through supported network commands and validate its serving SVM. That approach targets a different ONTAP condition: An administrator changes a physical port IP address instead of the protocol-serving LIF and disrupts the intended SVM endpoint. At Boreal Foods, for production inventory files and reporting LUNs, the actual failure is: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. That alternative by itself would not prove the needed outcome: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Question 324

During a routine health assessment at Boreal Foods, the ONTAP administrators find the following ONTAP problem: A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A packet path test identifies the blocked hop and the corrected route restores the mount attempt.
  2. The LIF returns to an appropriate port and client traffic reaches the required VLAN.
  3. The intended logical endpoint has the approved address and existing unrelated LIFs are unchanged.
  4. Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Explanation

Correct Answer

D:

Counters stop increasing after the affected physical link is corrected and throughput stabilizes. The observation verifies that the chosen action (Inspect interface error counters, switch port health and cabling before changing ONTAP performance policies) has corrected the initiating failure (A network fault investigation focuses on storage CPU while data ports report errors and discards during large file transfers). This is directly measurable for Boreal Foods's production inventory files and reporting LUNs rather than merely reporting task completion.

Incorrect Answers

A:

A packet path test identifies the blocked hop and the corrected route restores the mount attempt. This is a valid test for another condition (A NAS mount times out from only one subnet and technicians immediately change NFS export policies without testing network reachability) after a different correction (Check LIF status, VLAN mapping, routing and intermediate ACLs before changing protocol authorization). It does not establish the necessary result for Boreal Foods's production inventory files and reporting LUNs: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

B:

The LIF returns to an appropriate port and client traffic reaches the required VLAN. This is a valid test for another condition (An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain) after a different correction (Review LIF current port, home port, broadcast domain and failover-group membership). It does not establish the necessary result for Boreal Foods's production inventory files and reporting LUNs: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

C:

The intended logical endpoint has the approved address and existing unrelated LIFs are unchanged. This is a valid test for another condition (An administrator changes a physical port IP address instead of the protocol-serving LIF and disrupts the intended SVM endpoint) after a different correction (Modify the correct ONTAP logical interface through supported network commands and validate its serving SVM). It does not establish the necessary result for Boreal Foods's production inventory files and reporting LUNs: Counters stop increasing after the affected physical link is corrected and throughput stabilizes.

Question 325

Riverbend Automotive manages vehicle diagnostics and engineering data under a documented recovery-time objective. A storage incident report states: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. Which administrative action BEST addresses the specific problem?

  1. Review LIF current port, home port, broadcast domain and failover-group membership.
  2. Use console or alternative supported management access to repair the affected management LIF or route.
  3. Examine cluster network membership, switch configuration and inter-node connectivity independently of client data.
  4. Validate supported host MPIO and separate target network paths to the ONTAP SVM.

Explanation

Correct Answer

C:

Examine cluster network membership, switch configuration and inter-node connectivity independently of client data. This action addresses the specific failure: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. For Riverbend Automotive's vehicle diagnostics and engineering data, a successful implementation should produce the following evidence: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

Incorrect Answers

A:

Review LIF current port, home port, broadcast domain and failover-group membership. That approach targets a different ONTAP condition: An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain. At Riverbend Automotive, for vehicle diagnostics and engineering data, the actual failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. That alternative by itself would not prove the needed outcome: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

B:

Use console or alternative supported management access to repair the affected management LIF or route. That approach targets a different ONTAP condition: An address change makes management unreachable and the runbook incorrectly attempts to delete the cluster and recreate the storage virtual machines. At Riverbend Automotive, for vehicle diagnostics and engineering data, the actual failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. That alternative by itself would not prove the needed outcome: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

D:

Validate supported host MPIO and separate target network paths to the ONTAP SVM. That approach targets a different ONTAP condition: An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path. At Riverbend Automotive, for vehicle diagnostics and engineering data, the actual failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. That alternative by itself would not prove the needed outcome: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

Question 326

Riverbend Automotive manages vehicle diagnostics and engineering data under a documented recovery-time objective. A storage incident report states: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. The LIF returns to an appropriate port and client traffic reaches the required VLAN.
  2. One target path can be interrupted while I/O continues over the surviving healthy path.
  3. Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.
  4. Cluster management access returns and pre-existing SVM datasets remain intact.

Explanation

Correct Answer

C:

Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot. The observation verifies that the chosen action (Examine cluster network membership, switch configuration and inter-node connectivity independently of client data) has corrected the initiating failure (A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected). This is directly measurable for Riverbend Automotive's vehicle diagnostics and engineering data rather than merely reporting task completion.

Incorrect Answers

A:

The LIF returns to an appropriate port and client traffic reaches the required VLAN. This is a valid test for another condition (An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain) after a different correction (Review LIF current port, home port, broadcast domain and failover-group membership). It does not establish the necessary result for Riverbend Automotive's vehicle diagnostics and engineering data: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

B:

One target path can be interrupted while I/O continues over the surviving healthy path. This is a valid test for another condition (An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path) after a different correction (Validate supported host MPIO and separate target network paths to the ONTAP SVM). It does not establish the necessary result for Riverbend Automotive's vehicle diagnostics and engineering data: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

D:

Cluster management access returns and pre-existing SVM datasets remain intact. This is a valid test for another condition (An address change makes management unreachable and the runbook incorrectly attempts to delete the cluster and recreate the storage virtual machines) after a different correction (Use console or alternative supported management access to repair the affected management LIF or route). It does not establish the necessary result for Riverbend Automotive's vehicle diagnostics and engineering data: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

Question 327

For Pinecrest Research, a proposed storage change affects scientific datasets and GPU project file shares. The identified control failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. Which administrative action BEST addresses the specific problem?

  1. Validate supported host MPIO and separate target network paths to the ONTAP SVM.
  2. Review LIF current port, home port, broadcast domain and failover-group membership.
  3. Use console or alternative supported management access to repair the affected management LIF or route.
  4. Examine cluster network membership, switch configuration and inter-node connectivity independently of client data.

Explanation

Correct Answer

D:

Examine cluster network membership, switch configuration and inter-node connectivity independently of client data. This action addresses the specific failure: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. For Pinecrest Research's scientific datasets and GPU project file shares, a successful implementation should produce the following evidence: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

Incorrect Answers

A:

Validate supported host MPIO and separate target network paths to the ONTAP SVM. That approach targets a different ONTAP condition: An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path. At Pinecrest Research, for scientific datasets and GPU project file shares, the actual failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. That alternative by itself would not prove the needed outcome: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

B:

Review LIF current port, home port, broadcast domain and failover-group membership. That approach targets a different ONTAP condition: An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain. At Pinecrest Research, for scientific datasets and GPU project file shares, the actual failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. That alternative by itself would not prove the needed outcome: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

C:

Use console or alternative supported management access to repair the affected management LIF or route. That approach targets a different ONTAP condition: An address change makes management unreachable and the runbook incorrectly attempts to delete the cluster and recreate the storage virtual machines. At Pinecrest Research, for scientific datasets and GPU project file shares, the actual failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. That alternative by itself would not prove the needed outcome: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

Question 328

For Pinecrest Research, a proposed storage change affects scientific datasets and GPU project file shares. The identified control failure is: A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.
  2. One target path can be interrupted while I/O continues over the surviving healthy path.
  3. The LIF returns to an appropriate port and client traffic reaches the required VLAN.
  4. Cluster management access returns and pre-existing SVM datasets remain intact.

Explanation

Correct Answer

A:

Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot. The observation verifies that the chosen action (Examine cluster network membership, switch configuration and inter-node connectivity independently of client data) has corrected the initiating failure (A cluster LIF intermittently goes offline after a switching change but client data LIFs remain unaffected). This is directly measurable for Pinecrest Research's scientific datasets and GPU project file shares rather than merely reporting task completion.

Incorrect Answers

B:

One target path can be interrupted while I/O continues over the surviving healthy path. This is a valid test for another condition (An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path) after a different correction (Validate supported host MPIO and separate target network paths to the ONTAP SVM). It does not establish the necessary result for Pinecrest Research's scientific datasets and GPU project file shares: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

C:

The LIF returns to an appropriate port and client traffic reaches the required VLAN. This is a valid test for another condition (An ONTAP data LIF remains administratively up but has moved to a port on the wrong broadcast domain) after a different correction (Review LIF current port, home port, broadcast domain and failover-group membership). It does not establish the necessary result for Pinecrest Research's scientific datasets and GPU project file shares: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

D:

Cluster management access returns and pre-existing SVM datasets remain intact. This is a valid test for another condition (An address change makes management unreachable and the runbook incorrectly attempts to delete the cluster and recreate the storage virtual machines) after a different correction (Use console or alternative supported management access to repair the affected management LIF or route). It does not establish the necessary result for Pinecrest Research's scientific datasets and GPU project file shares: Inter-node cluster health checks succeed and cluster LIF states stay stable across a switch reboot.

Question 329

At Crescent Education, the production environment supports student records and backup repositories with separately managed development and production resources. Investigators find: A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation. Which administrative action BEST addresses the specific problem?

  1. Inspect the SVM routing table and configure the missing network or default route.
  2. Measure network RTT, packet loss and route changes alongside ONTAP latency counters.
  3. Align end-to-end MTU or revert to a consistently supported size across the entire path.
  4. Validate supported host MPIO and separate target network paths to the ONTAP SVM.

Explanation

Correct Answer

B:

Measure network RTT, packet loss and route changes alongside ONTAP latency counters. This action addresses the specific failure: A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation. For Crescent Education's student records and backup repositories, a successful implementation should produce the following evidence: The impaired WAN hop is identified and client response time recovers without changing volume placement.

Incorrect Answers

A:

Inspect the SVM routing table and configure the missing network or default route. That approach targets a different ONTAP condition: Only clients behind a new router cannot access SVM IP addresses because no return route is configured. At Crescent Education, for student records and backup repositories, the actual failure is: A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation. That alternative by itself would not prove the needed outcome: The impaired WAN hop is identified and client response time recovers without changing volume placement.

C:

Align end-to-end MTU or revert to a consistently supported size across the entire path. That approach targets a different ONTAP condition: A storage network shows intermittent packet loss after enabling a jumbo MTU on only some devices. At Crescent Education, for student records and backup repositories, the actual failure is: A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation. That alternative by itself would not prove the needed outcome: The impaired WAN hop is identified and client response time recovers without changing volume placement.

D:

Validate supported host MPIO and separate target network paths to the ONTAP SVM. That approach targets a different ONTAP condition: An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path. At Crescent Education, for student records and backup repositories, the actual failure is: A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation. That alternative by itself would not prove the needed outcome: The impaired WAN hop is identified and client response time recovers without changing volume placement.

Question 330

At Crescent Education, the production environment supports student records and backup repositories with separately managed development and production resources. Investigators find: A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. Large packet connectivity tests pass without fragmentation or loss on the production path.
  2. The impaired WAN hop is identified and client response time recovers without changing volume placement.
  3. One target path can be interrupted while I/O continues over the surviving healthy path.
  4. A routed client and storage LIF exchange traffic symmetrically with no wrong-gateway replies.

Explanation

Correct Answer

B:

The impaired WAN hop is identified and client response time recovers without changing volume placement. The observation verifies that the chosen action (Measure network RTT, packet loss and route changes alongside ONTAP latency counters) has corrected the initiating failure (A NAS session is slow from one site despite healthy volume latency and operators attribute the incident to disk saturation). This is directly measurable for Crescent Education's student records and backup repositories rather than merely reporting task completion.

Incorrect Answers

A:

Large packet connectivity tests pass without fragmentation or loss on the production path. This is a valid test for another condition (A storage network shows intermittent packet loss after enabling a jumbo MTU on only some devices) after a different correction (Align end-to-end MTU or revert to a consistently supported size across the entire path). It does not establish the necessary result for Crescent Education's student records and backup repositories: The impaired WAN hop is identified and client response time recovers without changing volume placement.

C:

One target path can be interrupted while I/O continues over the surviving healthy path. This is a valid test for another condition (An iSCSI session drops during switch maintenance because host multipathing uses only one reachable storage target path) after a different correction (Validate supported host MPIO and separate target network paths to the ONTAP SVM). It does not establish the necessary result for Crescent Education's student records and backup repositories: The impaired WAN hop is identified and client response time recovers without changing volume placement.

D:

A routed client and storage LIF exchange traffic symmetrically with no wrong-gateway replies. This is a valid test for another condition (Only clients behind a new router cannot access SVM IP addresses because no return route is configured) after a different correction (Inspect the SVM routing table and configure the missing network or default route). It does not establish the necessary result for Crescent Education's student records and backup repositories: The impaired WAN hop is identified and client response time recovers without changing volume placement.