McAfee-Secured Website

Exam Code: NS0-165

Exam Name: NetApp Certified Data Administrator, ONTAP

Certification Provider: Network Appliance

Corresponding Certification: NCDA ONTAP

100% Network Appliance NS0-165 Guaranteed Success With Testking Training Materials

Get Real NS0-165 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

60 Questions & Answers with Testing Engine

"NetApp Certified Data Administrator, ONTAP Exam", also known as NS0-165 exam, is a Network Appliance certification exam.

Pass your tests with the always up-to-date NS0-165 Exam Engine. Your NS0-165 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

Network Appliance NS0-165 Practice Test 23

Question 220

During a routine health assessment at Evergreen Hospital, the data protection team find the following ONTAP problem: An application demands a very large distributed NAS dataset but its design relies on a single volume that cannot satisfy planning limits. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A renamed or remounted volume remains reachable through the documented SVM namespace route.
  2. The workload traverses the unified namespace at the validated capacity without manual per-shard paths.
  3. A client lookup of the intended mount path resolves to the new volume and reads its data.
  4. Clients access one logical path while aggregate monitoring identifies its distributed constituents.

Explanation

Correct Answer

B:

The workload traverses the unified namespace at the validated capacity without manual per-shard paths. The observation verifies that the chosen action (Evaluate supported FlexGroup scaling and namespace requirements for the data distribution pattern) has corrected the initiating failure (An application demands a very large distributed NAS dataset but its design relies on a single volume that cannot satisfy planning limits). This is directly measurable for Evergreen Hospital's virtual machine datastores and clinical files rather than merely reporting task completion.

Incorrect Answers

A:

A renamed or remounted volume remains reachable through the documented SVM namespace route. This is a valid test for another condition (A storage team grants clients direct access to an unmounted volume's internal cluster path instead of the SVM junction namespace) after a different correction (Establish a consistent SVM namespace and use junction paths for client-visible exports). It does not establish the necessary result for Evergreen Hospital's virtual machine datastores and clinical files: The workload traverses the unified namespace at the validated capacity without manual per-shard paths.

C:

A client lookup of the intended mount path resolves to the new volume and reads its data. This is a valid test for another condition (A NAS administrator creates a FlexVol but never mounts it in the SVM namespace and users cannot access its intended path) after a different correction (Mount the volume using an appropriate junction path within the serving SVM namespace). It does not establish the necessary result for Evergreen Hospital's virtual machine datastores and clinical files: The workload traverses the unified namespace at the validated capacity without manual per-shard paths.

D:

Clients access one logical path while aggregate monitoring identifies its distributed constituents. This is a valid test for another condition (A FlexGroup design treats all member constituents as separate user-facing shares rather than one distributed namespace) after a different correction (Present the supported FlexGroup as a single logical NAS namespace and validate constituent placement). It does not establish the necessary result for Evergreen Hospital's virtual machine datastores and clinical files: The workload traverses the unified namespace at the validated capacity without manual per-shard paths.

Question 221

For Granite Peak Sports, a proposed storage change affects video media archives and analytics database storage. The identified control failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. Which administrative action BEST addresses the specific problem?

  1. Compare logical, used, and efficiency metrics from the correct volume and local-tier counters.
  2. Combine thin provisioning with physical capacity forecasts and thresholds before permitting more allocation.
  3. Monitor snapshot and actual physical consumption independently of promised logical capacity.
  4. Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters.

Explanation

Correct Answer

B:

Combine thin provisioning with physical capacity forecasts and thresholds before permitting more allocation. This action addresses the specific failure: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. For Granite Peak Sports's video media archives and analytics database storage, a successful implementation should produce the following evidence: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

Incorrect Answers

A:

Compare logical, used, and efficiency metrics from the correct volume and local-tier counters. That approach targets a different ONTAP condition: A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains. At Granite Peak Sports, for video media archives and analytics database storage, the actual failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. That alternative by itself would not prove the needed outcome: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

C:

Monitor snapshot and actual physical consumption independently of promised logical capacity. That approach targets a different ONTAP condition: An administrator expects thin provisioning to prevent capacity faults even when snapshots and writes consume all physical space. At Granite Peak Sports, for video media archives and analytics database storage, the actual failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. That alternative by itself would not prove the needed outcome: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

D:

Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters. That approach targets a different ONTAP condition: An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication. At Granite Peak Sports, for video media archives and analytics database storage, the actual failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. That alternative by itself would not prove the needed outcome: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

Question 222

For Granite Peak Sports, a proposed storage change affects video media archives and analytics database storage. The identified control failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A simulated growth event produces an alert before physical exhaustion and preserves writable space.
  2. A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads.
  3. A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.
  4. An audited capacity report reconciles physical blocks and logical consumption without double counting.

Explanation

Correct Answer

C:

A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload. The observation verifies that the chosen action (Combine thin provisioning with physical capacity forecasts and thresholds before permitting more allocation) has corrected the initiating failure (A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills). This is directly measurable for Granite Peak Sports's video media archives and analytics database storage rather than merely reporting task completion.

Incorrect Answers

A:

A simulated growth event produces an alert before physical exhaustion and preserves writable space. This is a valid test for another condition (An administrator expects thin provisioning to prevent capacity faults even when snapshots and writes consume all physical space) after a different correction (Monitor snapshot and actual physical consumption independently of promised logical capacity). It does not establish the necessary result for Granite Peak Sports's video media archives and analytics database storage: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

B:

A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads. This is a valid test for another condition (An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication) after a different correction (Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters). It does not establish the necessary result for Granite Peak Sports's video media archives and analytics database storage: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

D:

An audited capacity report reconciles physical blocks and logical consumption without double counting. This is a valid test for another condition (A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains) after a different correction (Compare logical, used, and efficiency metrics from the correct volume and local-tier counters). It does not establish the necessary result for Granite Peak Sports's video media archives and analytics database storage: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

Question 223

A storage engineer reviewing Copper Hill Studios's creative assets and rendering scratch datasets observes: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. Which administrative action BEST addresses the specific problem?

  1. Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters.
  2. Monitor snapshot and actual physical consumption independently of promised logical capacity.
  3. Combine thin provisioning with physical capacity forecasts and thresholds before permitting more allocation.
  4. Compare logical, used, and efficiency metrics from the correct volume and local-tier counters.

Explanation

Correct Answer

C:

Combine thin provisioning with physical capacity forecasts and thresholds before permitting more allocation. This action addresses the specific failure: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. For Copper Hill Studios's creative assets and rendering scratch datasets, a successful implementation should produce the following evidence: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

Incorrect Answers

A:

Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters. That approach targets a different ONTAP condition: An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication. At Copper Hill Studios, for creative assets and rendering scratch datasets, the actual failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. That alternative by itself would not prove the needed outcome: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

B:

Monitor snapshot and actual physical consumption independently of promised logical capacity. That approach targets a different ONTAP condition: An administrator expects thin provisioning to prevent capacity faults even when snapshots and writes consume all physical space. At Copper Hill Studios, for creative assets and rendering scratch datasets, the actual failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. That alternative by itself would not prove the needed outcome: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

D:

Compare logical, used, and efficiency metrics from the correct volume and local-tier counters. That approach targets a different ONTAP condition: A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains. At Copper Hill Studios, for creative assets and rendering scratch datasets, the actual failure is: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. That alternative by itself would not prove the needed outcome: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

Question 224

A storage engineer reviewing Copper Hill Studios's creative assets and rendering scratch datasets observes: A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. An audited capacity report reconciles physical blocks and logical consumption without double counting.
  2. A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.
  3. A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads.
  4. A simulated growth event produces an alert before physical exhaustion and preserves writable space.

Explanation

Correct Answer

B:

A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload. The observation verifies that the chosen action (Combine thin provisioning with physical capacity forecasts and thresholds before permitting more allocation) has corrected the initiating failure (A thin-provisioned aggregate is overcommitted without physical free-space alerts and new writes fail when the local tier fills). This is directly measurable for Copper Hill Studios's creative assets and rendering scratch datasets rather than merely reporting task completion.

Incorrect Answers

A:

An audited capacity report reconciles physical blocks and logical consumption without double counting. This is a valid test for another condition (A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains) after a different correction (Compare logical, used, and efficiency metrics from the correct volume and local-tier counters). It does not establish the necessary result for Copper Hill Studios's creative assets and rendering scratch datasets: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

C:

A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads. This is a valid test for another condition (An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication) after a different correction (Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters). It does not establish the necessary result for Copper Hill Studios's creative assets and rendering scratch datasets: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

D:

A simulated growth event produces an alert before physical exhaustion and preserves writable space. This is a valid test for another condition (An administrator expects thin provisioning to prevent capacity faults even when snapshots and writes consume all physical space) after a different correction (Monitor snapshot and actual physical consumption independently of promised logical capacity). It does not establish the necessary result for Copper Hill Studios's creative assets and rendering scratch datasets: A capacity stress rehearsal raises a threshold alert and spare capacity remains for the critical workload.

Question 225

During a resilience rehearsal at Arborstone Tech, the storage reliability team find the following ONTAP problem: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. Which administrative action BEST addresses the specific problem?

  1. Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters.
  2. Evaluate supported FabricPool or equivalent tiering policy and object-tier compatibility for cold blocks.
  3. Compare logical, used, and efficiency metrics from the correct volume and local-tier counters.
  4. Enable supported deduplication policies and compare physical blocks before and after optimization.

Explanation

Correct Answer

D:

Enable supported deduplication policies and compare physical blocks before and after optimization. This action addresses the specific failure: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. For Arborstone Tech's SaaS application volumes and VM datastore protection, a successful implementation should produce the following evidence: The measurement shows fewer physical blocks with identical logical data and application read results.

Incorrect Answers

A:

Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters. That approach targets a different ONTAP condition: An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication. At Arborstone Tech, for SaaS application volumes and VM datastore protection, the actual failure is: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. That alternative by itself would not prove the needed outcome: The measurement shows fewer physical blocks with identical logical data and application read results.

B:

Evaluate supported FabricPool or equivalent tiering policy and object-tier compatibility for cold blocks. That approach targets a different ONTAP condition: A cold dataset remains on premium local flash indefinitely despite an approved performance tiering requirement. At Arborstone Tech, for SaaS application volumes and VM datastore protection, the actual failure is: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. That alternative by itself would not prove the needed outcome: The measurement shows fewer physical blocks with identical logical data and application read results.

C:

Compare logical, used, and efficiency metrics from the correct volume and local-tier counters. That approach targets a different ONTAP condition: A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains. At Arborstone Tech, for SaaS application volumes and VM datastore protection, the actual failure is: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. That alternative by itself would not prove the needed outcome: The measurement shows fewer physical blocks with identical logical data and application read results.

Question 226

During a resilience rehearsal at Arborstone Tech, the storage reliability team find the following ONTAP problem: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. Cold-block location changes according to policy while frequently used blocks meet the latency objective.
  2. The measurement shows fewer physical blocks with identical logical data and application read results.
  3. A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads.
  4. An audited capacity report reconciles physical blocks and logical consumption without double counting.

Explanation

Correct Answer

B:

The measurement shows fewer physical blocks with identical logical data and application read results. The observation verifies that the chosen action (Enable supported deduplication policies and compare physical blocks before and after optimization) has corrected the initiating failure (A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings). This is directly measurable for Arborstone Tech's SaaS application volumes and VM datastore protection rather than merely reporting task completion.

Incorrect Answers

A:

Cold-block location changes according to policy while frequently used blocks meet the latency objective. This is a valid test for another condition (A cold dataset remains on premium local flash indefinitely despite an approved performance tiering requirement) after a different correction (Evaluate supported FabricPool or equivalent tiering policy and object-tier compatibility for cold blocks). It does not establish the necessary result for Arborstone Tech's SaaS application volumes and VM datastore protection: The measurement shows fewer physical blocks with identical logical data and application read results.

C:

A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads. This is a valid test for another condition (An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication) after a different correction (Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters). It does not establish the necessary result for Arborstone Tech's SaaS application volumes and VM datastore protection: The measurement shows fewer physical blocks with identical logical data and application read results.

D:

An audited capacity report reconciles physical blocks and logical consumption without double counting. This is a valid test for another condition (A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains) after a different correction (Compare logical, used, and efficiency metrics from the correct volume and local-tier counters). It does not establish the necessary result for Arborstone Tech's SaaS application volumes and VM datastore protection: The measurement shows fewer physical blocks with identical logical data and application read results.

Question 227

The data protection team at Clearwater Airport are responsible for operations databases and maintenance records. Their assessment shows: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. Which administrative action BEST addresses the specific problem?

  1. Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters.
  2. Compare logical, used, and efficiency metrics from the correct volume and local-tier counters.
  3. Evaluate supported FabricPool or equivalent tiering policy and object-tier compatibility for cold blocks.
  4. Enable supported deduplication policies and compare physical blocks before and after optimization.

Explanation

Correct Answer

D:

Enable supported deduplication policies and compare physical blocks before and after optimization. This action addresses the specific failure: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. For Clearwater Airport's operations databases and maintenance records, a successful implementation should produce the following evidence: The measurement shows fewer physical blocks with identical logical data and application read results.

Incorrect Answers

A:

Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters. That approach targets a different ONTAP condition: An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication. At Clearwater Airport, for operations databases and maintenance records, the actual failure is: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. That alternative by itself would not prove the needed outcome: The measurement shows fewer physical blocks with identical logical data and application read results.

B:

Compare logical, used, and efficiency metrics from the correct volume and local-tier counters. That approach targets a different ONTAP condition: A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains. At Clearwater Airport, for operations databases and maintenance records, the actual failure is: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. That alternative by itself would not prove the needed outcome: The measurement shows fewer physical blocks with identical logical data and application read results.

C:

Evaluate supported FabricPool or equivalent tiering policy and object-tier compatibility for cold blocks. That approach targets a different ONTAP condition: A cold dataset remains on premium local flash indefinitely despite an approved performance tiering requirement. At Clearwater Airport, for operations databases and maintenance records, the actual failure is: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. That alternative by itself would not prove the needed outcome: The measurement shows fewer physical blocks with identical logical data and application read results.

Question 228

The data protection team at Clearwater Airport are responsible for operations databases and maintenance records. Their assessment shows: A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. Cold-block location changes according to policy while frequently used blocks meet the latency objective.
  2. An audited capacity report reconciles physical blocks and logical consumption without double counting.
  3. The measurement shows fewer physical blocks with identical logical data and application read results.
  4. A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads.

Explanation

Correct Answer

C:

The measurement shows fewer physical blocks with identical logical data and application read results. The observation verifies that the chosen action (Enable supported deduplication policies and compare physical blocks before and after optimization) has corrected the initiating failure (A virtual desktop dataset contains repeated OS blocks but storage operators never evaluate deduplication savings). This is directly measurable for Clearwater Airport's operations databases and maintenance records rather than merely reporting task completion.

Incorrect Answers

A:

Cold-block location changes according to policy while frequently used blocks meet the latency objective. This is a valid test for another condition (A cold dataset remains on premium local flash indefinitely despite an approved performance tiering requirement) after a different correction (Evaluate supported FabricPool or equivalent tiering policy and object-tier compatibility for cold blocks). It does not establish the necessary result for Clearwater Airport's operations databases and maintenance records: The measurement shows fewer physical blocks with identical logical data and application read results.

B:

An audited capacity report reconciles physical blocks and logical consumption without double counting. This is a valid test for another condition (A storage report confuses logical provisioned space with physical written space and declares impossible capacity gains) after a different correction (Compare logical, used, and efficiency metrics from the correct volume and local-tier counters). It does not establish the necessary result for Clearwater Airport's operations databases and maintenance records: The measurement shows fewer physical blocks with identical logical data and application read results.

D:

A synthetic sparse/zero-filled dataset shows appropriate physical savings without altered logical reads. This is a valid test for another condition (An efficiency report claims all zero-filled blocks consume full physical space despite enabled zero-block deduplication) after a different correction (Validate deduplication and zero-block elimination using the relevant ONTAP efficiency counters). It does not establish the necessary result for Clearwater Airport's operations databases and maintenance records: The measurement shows fewer physical blocks with identical logical data and application read results.

Question 229

For Oak River Energy, a proposed storage change affects plant historian archives and virtual machine storage. The identified control failure is: A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern. Which administrative action BEST addresses the specific problem?

  1. Schedule or tune supported background efficiency operations away from the workload's critical window.
  2. Select supported inline or postprocess compression settings based on platform and benchmark evidence.
  3. Verify platform-specific efficiency defaults and any hardware offload support before changing compression settings.
  4. Monitor snapshot and actual physical consumption independently of promised logical capacity.

Explanation

Correct Answer

B:

Select supported inline or postprocess compression settings based on platform and benchmark evidence. This action addresses the specific failure: A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern. For Oak River Energy's plant historian archives and virtual machine storage, a successful implementation should produce the following evidence: A representative workload achieves acceptable latency with recorded physical space savings.

Incorrect Answers

A:

Schedule or tune supported background efficiency operations away from the workload's critical window. That approach targets a different ONTAP condition: A dedupe initiative schedules postprocess efficiency during a backup peak and reports extra response-time pressure. At Oak River Energy, for plant historian archives and virtual machine storage, the actual failure is: A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern. That alternative by itself would not prove the needed outcome: A representative workload achieves acceptable latency with recorded physical space savings.

C:

Verify platform-specific efficiency defaults and any hardware offload support before changing compression settings. That approach targets a different ONTAP condition: A performance review assumes compression must always be disabled on AFF regardless of the hardware offload and ONTAP version. At Oak River Energy, for plant historian archives and virtual machine storage, the actual failure is: A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern. That alternative by itself would not prove the needed outcome: A representative workload achieves acceptable latency with recorded physical space savings.

D:

Monitor snapshot and actual physical consumption independently of promised logical capacity. That approach targets a different ONTAP condition: An administrator expects thin provisioning to prevent capacity faults even when snapshots and writes consume all physical space. At Oak River Energy, for plant historian archives and virtual machine storage, the actual failure is: A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern. That alternative by itself would not prove the needed outcome: A representative workload achieves acceptable latency with recorded physical space savings.

Question 230

For Oak River Energy, a proposed storage change affects plant historian archives and virtual machine storage. The identified control failure is: A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern. The team reports that the correction is complete. Which observation BEST proves the stated problem is resolved?

  1. A representative workload achieves acceptable latency with recorded physical space savings.
  2. A simulated growth event produces an alert before physical exhaustion and preserves writable space.
  3. The chosen configuration retains supported efficiency behavior with measured CPU and latency evidence.
  4. Measured client latency during backup remains within budget while efficiency work eventually completes.

Explanation

Correct Answer

A:

A representative workload achieves acceptable latency with recorded physical space savings. The observation verifies that the chosen action (Select supported inline or postprocess compression settings based on platform and benchmark evidence) has corrected the initiating failure (A mixed-media workload applies compression indiscriminately without testing CPU and latency impact on its actual access pattern). This is directly measurable for Oak River Energy's plant historian archives and virtual machine storage rather than merely reporting task completion.

Incorrect Answers

B:

A simulated growth event produces an alert before physical exhaustion and preserves writable space. This is a valid test for another condition (An administrator expects thin provisioning to prevent capacity faults even when snapshots and writes consume all physical space) after a different correction (Monitor snapshot and actual physical consumption independently of promised logical capacity). It does not establish the necessary result for Oak River Energy's plant historian archives and virtual machine storage: A representative workload achieves acceptable latency with recorded physical space savings.

C:

The chosen configuration retains supported efficiency behavior with measured CPU and latency evidence. This is a valid test for another condition (A performance review assumes compression must always be disabled on AFF regardless of the hardware offload and ONTAP version) after a different correction (Verify platform-specific efficiency defaults and any hardware offload support before changing compression settings). It does not establish the necessary result for Oak River Energy's plant historian archives and virtual machine storage: A representative workload achieves acceptable latency with recorded physical space savings.

D:

Measured client latency during backup remains within budget while efficiency work eventually completes. This is a valid test for another condition (A dedupe initiative schedules postprocess efficiency during a backup peak and reports extra response-time pressure) after a different correction (Schedule or tune supported background efficiency operations away from the workload's critical window). It does not establish the necessary result for Oak River Energy's plant historian archives and virtual machine storage: A representative workload achieves acceptable latency with recorded physical space savings.

NetApp Certified Data Administrator, ONTAP (NS0-165) Practice Tests