Question 430
At Ironwood Public Services, the city network service team is preparing a new municipal office activation. The operational constraint is an approved redundant path. The change ticket is marked completed for this reported failure: Power-hungry access points reset only when additional PoE devices start simultaneously. Which result BEST demonstrates that this specific issue was resolved?
Explanation
Correct Answer
No PoE shortage events occur when all expected devices start together. This is the relevant acceptance observation for the reported issue: Power-hungry access points reset only when additional PoE devices start simultaneously. The intended corrective choice is: Correlate PoE allocation events and switch power availability with device resets. At Ironwood Public Services, this outcome verifies actual operation under an approved redundant path, rather than only a ticket marked complete.
Incorrect Answers
Burst-time discards decline while end-to-end application latency stays within bounds. Such an observation would verify a separate issue: Short bursts overwhelm small interface buffers although average utilization is modest. It would follow the distinct action: Use high-resolution queue/drop monitoring to identify microbursts and tune supported queuing or traffic distribution. Here the reported failure is Power-hungry access points reset only when additional PoE devices start simultaneously. The decisive result for Ironwood Public Services must instead be: No PoE shortage events occur when all expected devices start together.
CPU and control-plane event rates return to acceptable baseline after the root cause is fixed. Such an observation would verify a separate issue: A campus distribution switch has persistent high CPU but interfaces have little bandwidth utilization. It would follow the distinct action: Inspect control-plane events, logging storms, routing churn and process statistics before adding link capacity. Here the reported failure is Power-hungry access points reset only when additional PoE devices start simultaneously. The decisive result for Ironwood Public Services must instead be: No PoE shortage events occur when all expected devices start together.
Many representative flows distribute across available paths while individual flows remain consistently hashed. Such an observation would verify a separate issue: A four-member routed ECMP bundle uses only one next hop for a few large sessions and appears uneven. It would follow the distinct action: Check traffic-hash distribution and per-flow load balancing before declaring failed links. Here the reported failure is Power-hungry access points reset only when additional PoE devices start simultaneously. The decisive result for Ironwood Public Services must instead be: No PoE shortage events occur when all expected devices start together.