Question 50
At Timberline Foods, the supply-chain network operations team is planning a processing-plant network review under a requirement for production-line reliability. Following a proposed correction, the change manager requires evidence for this original fault: Two access closets reuse a VLAN number that must not be bridged between them under the segmentation design. Which observation BEST demonstrates that the fix worked?
Explanation
Correct Answer
A trunk-state review and cross-closet tests confirm the VLAN is not bridged between unrelated security zones. This observation verifies the specific reported problem, Two access closets reuse a VLAN number that must not be bridged between them under the segmentation design. The intended correction was: Remove the unwanted VLAN from the connecting trunk and permit routing only through the approved boundary. It provides a directly testable outcome for the Timberline Foods environment rather than treating a completed change ticket as proof.
Incorrect Answers
Untagged client frames enter the intended VLAN and receive the correct subnet configuration. For Timberline Foods, that measurement would support a separate technical case: An endpoint is placed into a tagged VLAN although it sends untagged Ethernet frames. Its corresponding remedy is: Configure the correct untagged access membership on the user-facing port rather than expecting endpoint tagging. The reported Timberline Foods condition is Two access closets reuse a VLAN number that must not be bridged between them under the segmentation design. So the required outcome is: A trunk-state review and cross-closet tests confirm the VLAN is not bridged between unrelated security zones.
VLAN membership and routing tests demonstrate isolation between the named organizations. For Timberline Foods, that measurement would support a separate technical case: Two different organizations use the same VLAN label and an installer assumes the label alone guarantees isolation. Its corresponding remedy is: Assign and verify explicit VLAN identifiers and a documented tenancy boundary instead of relying on descriptions. The reported Timberline Foods condition is Two access closets reuse a VLAN number that must not be bridged between them under the segmentation design. So the required outcome is: A trunk-state review and cross-closet tests confirm the VLAN is not bridged between unrelated security zones.
The workstation learns in VLAN 120 and cannot reach a restricted VLAN without an authorized Layer 3 policy. For Timberline Foods, that measurement would support a separate technical case: A FortiSwitch access port is assigned to the default VLAN, but finance workstations must be isolated in VLAN 120. Its corresponding remedy is: Assign the correct permitted access VLAN to the endpoint port and confirm matching upstream VLAN handling. The reported Timberline Foods condition is Two access closets reuse a VLAN number that must not be bridged between them under the segmentation design. So the required outcome is: A trunk-state review and cross-closet tests confirm the VLAN is not bridged between unrelated security zones.