Question 550
At Brookside Manufacturing, the plant operations team is planning an industrial Ethernet modernization under a requirement for planned downtime and resilient cabling. Following a proposed correction, the change manager requires evidence for this original fault: A RADIUS outage causes every wired endpoint to gain unrestricted access because the fallback policy was chosen carelessly. Which observation BEST demonstrates that the fix worked?
Explanation
Correct Answer
During simulated RADIUS failure, approved endpoints follow the intended fallback and unknown endpoints remain limited. This observation verifies the specific reported problem, A RADIUS outage causes every wired endpoint to gain unrestricted access because the fallback policy was chosen carelessly. The intended correction was: Define supported authentication-failure handling that preserves least privilege and documented business continuity. It provides a directly testable outcome for the Brookside Manufacturing environment rather than treating a completed change ticket as proof.
Incorrect Answers
The inter-switch link forwards approved VLANs while user-facing ports retain required authentication controls. For Brookside Manufacturing, that measurement would support a separate technical case: A campus network has an 802.1X authentication loop because an access port connects to another managed switch rather than a user endpoint. Its corresponding remedy is: Match authentication and switch-to-switch trunk policy to the actual topology instead of applying endpoint rules indiscriminately. The reported Brookside Manufacturing condition is A RADIUS outage causes every wired endpoint to gain unrestricted access because the fallback policy was chosen carelessly. So the required outcome is: During simulated RADIUS failure, approved endpoints follow the intended fallback and unknown endpoints remain limited.
Authentication logs show the correct switch identity and both authorized and rejected tests behave as designed. For Brookside Manufacturing, that measurement would support a separate technical case: An enterprise uses the same RADIUS credentials for all access switches, preventing reliable identification of each authenticator. Its corresponding remedy is: Create properly scoped per-switch RADIUS client records and shared-secret management under approved policy. The reported Brookside Manufacturing condition is A RADIUS outage causes every wired endpoint to gain unrestricted access because the fallback policy was chosen carelessly. So the required outcome is: During simulated RADIUS failure, approved endpoints follow the intended fallback and unknown endpoints remain limited.
Expected appliance MACs remain connected while an excess unknown source triggers the configured violation action. For Brookside Manufacturing, that measurement would support a separate technical case: A storage appliance uses multiple legitimate MAC addresses but a strict per-port limit counts them as an attack. Its corresponding remedy is: Tune the supported maximum learned MAC allowance and enforcement behavior to the documented endpoint profile. The reported Brookside Manufacturing condition is A RADIUS outage causes every wired endpoint to gain unrestricted access because the fallback policy was chosen carelessly. So the required outcome is: During simulated RADIUS failure, approved endpoints follow the intended fallback and unknown endpoints remain limited.