McAfee-Secured Website

Exam Bundle

Exam Code: SK0-005

Exam Name CompTIA Server+ Certification Exam

Certification Provider: CompTIA

Corresponding Certification: CompTIA Server+

CompTIA SK0-005 Bundle $44.99

100% CompTIA SK0-005 Guaranteed Success With Testking Training Materials

Get Real SK0-005 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    SK0-005 Questions & Answers

    617 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual SK0-005 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • SK0-005 Video Course

    SK0-005 Video Course

    139 Video Lectures

    SK0-005 Video Course is developed by CompTIA Professionals to help you pass the SK0-005 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA Server+ Certification Exam exam.
  • Study Guide

    SK0-005 Study Guide

    533 PDF Pages

    Developed by industry experts, this 533-page guide spells out in painstaking detail all of the information you need to ace SK0-005 exam.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    617 Questions

    $124.99
  • SK0-005 Video Course

    Video Course

    139 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    533 PDF Pages

    $29.99

CompTIA SK0-005 Practice Test 64

Question 630

A server operations team encounters the following situation: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. An after-hours entry is attributable to a named authorized operator.
  2. An unbadged second entrant is denied or triggers a response under a test.
  3. A maintenance inspection validates the intended detection and suppression readiness.
  4. An access drill succeeds without opening unrestricted entry to bystanders.

Explanation

Correct Answer

C:

This is incident-specific acceptance evidence: A maintenance inspection validates the intended detection and suppression readiness. It verifies the action review and select an approved code-compliant suppression design with fire safety specialists. The failure under test was: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

Incorrect Answers

A:

This observation tests an unrelated Summarize physical security concepts case: A backup vault uses electronic locks but provides no log linking entries to actual individuals during off-hours maintenance. It may be true while the current failure persists; the decisive current cause is: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

B:

This observation tests an unrelated Summarize physical security concepts case: A badge reader opens a sensitive server room, but employees can tailgate through the unlocked door without additional control. It may be true while the current failure persists; the decisive current cause is: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

D:

This observation tests an unrelated Summarize physical security concepts case: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. It may be true while the current failure persists; the decisive current cause is: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

Question 631

A server operations team encounters the following situation: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. Which underlying cause most specifically explains the observed symptoms?

  1. Sensor placement overlooks the most likely leak collection area.
  2. A single door swipe cannot attest to every person crossing the threshold.
  3. A single authentication device can become an availability bottleneck.
  4. Fire protection must fit occupancy and equipment without ignoring life-safety rules.

Explanation

Correct Answer

D:

This root-cause explanation directly accounts for the reported condition: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. The corrective step is: Review and select an approved code-compliant suppression design with fire safety specialists. The verifying outcome is: A maintenance inspection validates the intended detection and suppression readiness.

Incorrect Answers

A:

This alternative cause would explain a different case: A hardware room has water-leak detection only at the ceiling, yet its cooling pipes run below the raised floor. It does not explain the actual incident's evidence. The present cause is: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

B:

This alternative cause would explain a different case: A badge reader opens a sensitive server room, but employees can tailgate through the unlocked door without additional control. It does not explain the actual incident's evidence. The present cause is: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

C:

This alternative cause would explain a different case: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. It does not explain the actual incident's evidence. The present cause is: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

Question 632

A server operations team encounters the following situation: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Schedule professional fire system inspections and documented drills.
  2. Review access logs and deactivate departed personnel credentials promptly.
  3. Test alarm recipients and thresholds during facility maintenance.
  4. Test physical access recovery under reader failure conditions.

Explanation

Correct Answer

A:

This control targets the underlying recurrence risk: Fire protection must fit occupancy and equipment without ignoring life-safety rules. It builds validation into the affected workflow and supports the expected recovery result: A maintenance inspection validates the intended detection and suppression readiness.

Incorrect Answers

B:

This control addresses a different scenario: A backup vault uses electronic locks but provides no log linking entries to actual individuals during off-hours maintenance. That event's root mechanism was shared or unaudited physical entry prevents accountability. The described incident instead arises from: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

C:

This control addresses a different scenario: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. That event's root mechanism was telemetry without notification does not produce operational response. The described incident instead arises from: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

D:

This control addresses a different scenario: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. That event's root mechanism was a single authentication device can become an availability bottleneck. The described incident instead arises from: Fire protection must fit occupancy and equipment without ignoring life-safety rules.

Question 633

A server operations team encounters the following situation: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Deploy suitable underfloor leak sensors at credible water paths.
  2. Set actionable HVAC temperature and humidity alarms with on-call escalation.
  3. Implement a supervised approved emergency access method with logging and two-person oversight.
  4. Install appropriate approved physical perimeter or vehicle protection measures.

Explanation

Correct Answer

C:

The preferred corrective action directly addresses the incident: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. The fault mechanism is a single authentication device can become an availability bottleneck. Expected confirmation is: An access drill succeeds without opening unrestricted entry to bystanders.

Incorrect Answers

A:

This action is better suited to a separate Summarize physical security concepts incident: A hardware room has water-leak detection only at the ceiling, yet its cooling pipes run below the raised floor. That case involves: Sensor placement overlooks the most likely leak collection area. Here the observed mechanism is instead: A single authentication device can become an availability bottleneck. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Summarize physical security concepts incident: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. That case involves: Telemetry without notification does not produce operational response. Here the observed mechanism is instead: A single authentication device can become an availability bottleneck. Applying the other repair would not directly resolve this fault.

D:

This action is better suited to a separate Summarize physical security concepts incident: A new data center's vehicle entrance has no barrier, allowing a delivery truck to approach the server-room exterior wall directly. That case involves: Access controls inside the room do not address vehicle intrusion risks at the perimeter. Here the observed mechanism is instead: A single authentication device can become an availability bottleneck. Applying the other repair would not directly resolve this fault.

Question 634

A server operations team encounters the following situation: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. An after-hours entry is attributable to a named authorized operator.
  2. A simulated sensor threshold sends an alert before equipment safety limits.
  3. Facility testing confirms the defined setback and barrier coverage.
  4. An access drill succeeds without opening unrestricted entry to bystanders.

Explanation

Correct Answer

D:

This is incident-specific acceptance evidence: An access drill succeeds without opening unrestricted entry to bystanders. It verifies the action implement a supervised approved emergency access method with logging and two-person oversight. The failure under test was: A single authentication device can become an availability bottleneck.

Incorrect Answers

A:

This observation tests an unrelated Summarize physical security concepts case: A backup vault uses electronic locks but provides no log linking entries to actual individuals during off-hours maintenance. It may be true while the current failure persists; the decisive current cause is: A single authentication device can become an availability bottleneck.

B:

This observation tests an unrelated Summarize physical security concepts case: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. It may be true while the current failure persists; the decisive current cause is: A single authentication device can become an availability bottleneck.

C:

This observation tests an unrelated Summarize physical security concepts case: A new data center's vehicle entrance has no barrier, allowing a delivery truck to approach the server-room exterior wall directly. It may be true while the current failure persists; the decisive current cause is: A single authentication device can become an availability bottleneck.

Question 635

A server operations team encounters the following situation: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. Which underlying cause most specifically explains the observed symptoms?

  1. A single authentication device can become an availability bottleneck.
  2. Sensor placement overlooks the most likely leak collection area.
  3. A single door swipe cannot attest to every person crossing the threshold.
  4. A shared physical key defeats the intended restricted access boundary.

Explanation

Correct Answer

A:

This root-cause explanation directly accounts for the reported condition: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. The corrective step is: Implement a supervised approved emergency access method with logging and two-person oversight. The verifying outcome is: An access drill succeeds without opening unrestricted entry to bystanders.

Incorrect Answers

B:

This alternative cause would explain a different case: A hardware room has water-leak detection only at the ceiling, yet its cooling pipes run below the raised floor. It does not explain the actual incident's evidence. The present cause is: A single authentication device can become an availability bottleneck.

C:

This alternative cause would explain a different case: A badge reader opens a sensitive server room, but employees can tailgate through the unlocked door without additional control. It does not explain the actual incident's evidence. The present cause is: A single authentication device can become an availability bottleneck.

D:

This alternative cause would explain a different case: A secure datacenter door shares its mechanical master key with a public storage area because facilities never separated key control. It does not explain the actual incident's evidence. The present cause is: A single authentication device can become an availability bottleneck.

Question 636

A server operations team encounters the following situation: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Audit key hierarchies whenever secured locations are added.
  2. Test physical access recovery under reader failure conditions.
  3. Audit tailgating and visitor escort behavior during access reviews.
  4. Schedule professional fire system inspections and documented drills.

Explanation

Correct Answer

B:

This control targets the underlying recurrence risk: A single authentication device can become an availability bottleneck. It builds validation into the affected workflow and supports the expected recovery result: An access drill succeeds without opening unrestricted entry to bystanders.

Incorrect Answers

A:

This control addresses a different scenario: A secure datacenter door shares its mechanical master key with a public storage area because facilities never separated key control. That event's root mechanism was a shared physical key defeats the intended restricted access boundary. The described incident instead arises from: A single authentication device can become an availability bottleneck.

C:

This control addresses a different scenario: A badge reader opens a sensitive server room, but employees can tailgate through the unlocked door without additional control. That event's root mechanism was a single door swipe cannot attest to every person crossing the threshold. The described incident instead arises from: A single authentication device can become an availability bottleneck.

D:

This control addresses a different scenario: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. That event's root mechanism was fire protection must fit occupancy and equipment without ignoring life-safety rules. The described incident instead arises from: A single authentication device can become an availability bottleneck.

Question 637

A server operations team encounters the following situation: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. Given the stated symptoms and constraints, which corrective action is the best next step?

  1. Rekey the sensitive area and implement controlled issuance and return tracking.
  2. Implement a supervised approved emergency access method with logging and two-person oversight.
  3. Review and select an approved code-compliant suppression design with fire safety specialists.
  4. Set actionable HVAC temperature and humidity alarms with on-call escalation.

Explanation

Correct Answer

D:

The preferred corrective action directly addresses the incident: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. The fault mechanism is telemetry without notification does not produce operational response. Expected confirmation is: A simulated sensor threshold sends an alert before equipment safety limits.

Incorrect Answers

A:

This action is better suited to a separate Summarize physical security concepts incident: A secure datacenter door shares its mechanical master key with a public storage area because facilities never separated key control. That case involves: A shared physical key defeats the intended restricted access boundary. Here the observed mechanism is instead: Telemetry without notification does not produce operational response. Applying the other repair would not directly resolve this fault.

B:

This action is better suited to a separate Summarize physical security concepts incident: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. That case involves: A single authentication device can become an availability bottleneck. Here the observed mechanism is instead: Telemetry without notification does not produce operational response. Applying the other repair would not directly resolve this fault.

C:

This action is better suited to a separate Summarize physical security concepts incident: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. That case involves: Fire protection must fit occupancy and equipment without ignoring life-safety rules. Here the observed mechanism is instead: Telemetry without notification does not produce operational response. Applying the other repair would not directly resolve this fault.

Question 638

A server operations team encounters the following situation: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. After making the corrective change, which result best demonstrates that this particular problem is resolved?

  1. A simulated sensor threshold sends an alert before equipment safety limits.
  2. Facility testing confirms the defined setback and barrier coverage.
  3. Unapproved public-area keys no longer open the datacenter entrance.
  4. A controlled sensor test reports the affected floor zone.

Explanation

Correct Answer

A:

This is incident-specific acceptance evidence: A simulated sensor threshold sends an alert before equipment safety limits. It verifies the action set actionable HVAC temperature and humidity alarms with on-call escalation. The failure under test was: Telemetry without notification does not produce operational response.

Incorrect Answers

B:

This observation tests an unrelated Summarize physical security concepts case: A new data center's vehicle entrance has no barrier, allowing a delivery truck to approach the server-room exterior wall directly. It may be true while the current failure persists; the decisive current cause is: Telemetry without notification does not produce operational response.

C:

This observation tests an unrelated Summarize physical security concepts case: A secure datacenter door shares its mechanical master key with a public storage area because facilities never separated key control. It may be true while the current failure persists; the decisive current cause is: Telemetry without notification does not produce operational response.

D:

This observation tests an unrelated Summarize physical security concepts case: A hardware room has water-leak detection only at the ceiling, yet its cooling pipes run below the raised floor. It may be true while the current failure persists; the decisive current cause is: Telemetry without notification does not produce operational response.

Question 639

A server operations team encounters the following situation: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. Which underlying cause most specifically explains the observed symptoms?

  1. A shared physical key defeats the intended restricted access boundary.
  2. Telemetry without notification does not produce operational response.
  3. Fire protection must fit occupancy and equipment without ignoring life-safety rules.
  4. A single authentication device can become an availability bottleneck.

Explanation

Correct Answer

B:

This root-cause explanation directly accounts for the reported condition: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. The corrective step is: Set actionable HVAC temperature and humidity alarms with on-call escalation. The verifying outcome is: A simulated sensor threshold sends an alert before equipment safety limits.

Incorrect Answers

A:

This alternative cause would explain a different case: A secure datacenter door shares its mechanical master key with a public storage area because facilities never separated key control. It does not explain the actual incident's evidence. The present cause is: Telemetry without notification does not produce operational response.

C:

This alternative cause would explain a different case: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. It does not explain the actual incident's evidence. The present cause is: Telemetry without notification does not produce operational response.

D:

This alternative cause would explain a different case: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. It does not explain the actual incident's evidence. The present cause is: Telemetry without notification does not produce operational response.

Question 640

A server operations team encounters the following situation: A rack has an environmental temperature probe but no alert threshold, and cooling stops overnight unnoticed. Which sustained operational control best reduces the likelihood of this same issue recurring?

  1. Audit tailgating and visitor escort behavior during access reviews.
  2. Schedule professional fire system inspections and documented drills.
  3. Test alarm recipients and thresholds during facility maintenance.
  4. Test physical access recovery under reader failure conditions.

Explanation

Correct Answer

C:

This control targets the underlying recurrence risk: Telemetry without notification does not produce operational response. It builds validation into the affected workflow and supports the expected recovery result: A simulated sensor threshold sends an alert before equipment safety limits.

Incorrect Answers

A:

This control addresses a different scenario: A badge reader opens a sensitive server room, but employees can tailgate through the unlocked door without additional control. That event's root mechanism was a single door swipe cannot attest to every person crossing the threshold. The described incident instead arises from: Telemetry without notification does not produce operational response.

B:

This control addresses a different scenario: A server room's fire response plan uses ordinary water sprinklers without assessing equipment damage and personnel safety for its facility type. That event's root mechanism was fire protection must fit occupancy and equipment without ignoring life-safety rules. The described incident instead arises from: Telemetry without notification does not produce operational response.

D:

This control addresses a different scenario: A facility installs biometric access controls but never defines fallback procedures for a failed scanner during an urgent authorized repair. That event's root mechanism was a single authentication device can become an availability bottleneck. The described incident instead arises from: Telemetry without notification does not produce operational response.