McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 82

Question 810

A workstation needs multiple high-bandwidth expansion cards but its compact motherboard has only one usable PCIe slot. Which test outcome demonstrates that the chosen action worked?

  1. The card negotiates the expected PCIe link width and generation.
  2. Each required adapter is detected and negotiates its intended link.
  3. Standoffs, ports and expansion clearances align with no mechanical strain.
  4. Mounting points align and the rear I/O fits without obstruction.

Explanation

Correct Answer

B:

Expansion capacity depends on PCIe topology, chassis space and shared controller lanes. The outcome “Each required adapter is detected and negotiates its intended link.” verifies the action “Select a motherboard and chassis with enough appropriate expansion lanes and physical clearances.” for this situation: A workstation needs multiple high-bandwidth expansion cards but its compact motherboard has only one usable PCIe slot.

Incorrect Answers

A:

Mechanical slot length does not guarantee equal electrical lane wiring. For the situation described—A workstation needs multiple high-bandwidth expansion cards but its compact motherboard has only one usable PCIe slot—this would not demonstrate the specified intervention. The relevant evidence is “Each required adapter is detected and negotiates its intended link.”.

C:

Full-size ATX boards exceed the mounting footprint of smaller cases. For the situation described—A workstation needs multiple high-bandwidth expansion cards but its compact motherboard has only one usable PCIe slot—this would not demonstrate the specified intervention. The relevant evidence is “Each required adapter is detected and negotiates its intended link.”.

D:

Board form factor must match chassis dimensions and standoff pattern. For the situation described—A workstation needs multiple high-bandwidth expansion cards but its compact motherboard has only one usable PCIe slot—this would not demonstrate the specified intervention. The relevant evidence is “Each required adapter is detected and negotiates its intended link.”.

Question 811

A technician installs an oversized tower CPU cooler that collides with the case side panel. Which action most directly addresses this problem?

  1. Check the slot's electrical lane allocation and device requirements before installation.
  2. Clean contact surfaces and apply appropriate fresh thermal interface material.
  3. Match firmware boot mode and partitioning to the supported installation configuration.
  4. Choose a cooling assembly within the case clearance and CPU thermal-design requirements.

Explanation

Correct Answer

D:

Cooling solution dimensions and heat-dissipation capability must both meet platform constraints. In this situation—A technician installs an oversized tower CPU cooler that collides with the case side panel—the right response is “Choose a cooling assembly within the case clearance and CPU thermal-design requirements.”. A confirming result would be “The chassis closes without pressure and a sustained CPU load stays within thermal limits.”.

Incorrect Answers

A:

Mechanical slot length does not guarantee equal electrical lane wiring. That does not directly address the condition described—A technician installs an oversized tower CPU cooler that collides with the case side panel. “Choose a cooling assembly within the case clearance and CPU thermal-design requirements.” is the appropriate response because cooling solution dimensions and heat-dissipation capability must both meet platform constraints.

B:

Thermal paste fills microscopic gaps between CPU and heatsink. That does not directly address the condition described—A technician installs an oversized tower CPU cooler that collides with the case side panel. “Choose a cooling assembly within the case clearance and CPU thermal-design requirements.” is the appropriate response because cooling solution dimensions and heat-dissipation capability must both meet platform constraints.

C:

UEFI and legacy BIOS boot paths have different requirements. That does not directly address the condition described—A technician installs an oversized tower CPU cooler that collides with the case side panel. “Choose a cooling assembly within the case clearance and CPU thermal-design requirements.” is the appropriate response because cooling solution dimensions and heat-dissipation capability must both meet platform constraints.

Question 812

A technician installs an oversized tower CPU cooler that collides with the case side panel. Which result BEST confirms the problem has been resolved?

  1. The operating system detects a ready TPM and measured-boot features can initialize.
  2. The chassis closes without pressure and a sustained CPU load stays within thermal limits.
  3. Standoffs, ports and expansion clearances align with no mechanical strain.
  4. Stress-test temperatures remain within the processor's specifications.

Explanation

Correct Answer

B:

Cooling solution dimensions and heat-dissipation capability must both meet platform constraints. The outcome “The chassis closes without pressure and a sustained CPU load stays within thermal limits.” verifies the action “Choose a cooling assembly within the case clearance and CPU thermal-design requirements.” for this situation: A technician installs an oversized tower CPU cooler that collides with the case side panel.

Incorrect Answers

A:

TPM support relies on firmware/hardware configuration, not on a network adapter. For the situation described—A technician installs an oversized tower CPU cooler that collides with the case side panel—this would not demonstrate the specified intervention. The relevant evidence is “The chassis closes without pressure and a sustained CPU load stays within thermal limits.”.

C:

Full-size ATX boards exceed the mounting footprint of smaller cases. For the situation described—A technician installs an oversized tower CPU cooler that collides with the case side panel—this would not demonstrate the specified intervention. The relevant evidence is “The chassis closes without pressure and a sustained CPU load stays within thermal limits.”.

D:

Thermal paste fills microscopic gaps between CPU and heatsink. For the situation described—A technician installs an oversized tower CPU cooler that collides with the case side panel—this would not demonstrate the specified intervention. The relevant evidence is “The chassis closes without pressure and a sustained CPU load stays within thermal limits.”.

Question 813

A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled. What is the MOST appropriate technician response?

  1. Enable the supported firmware TPM or compatible discrete TPM configuration.
  2. Enable the supported slot or install the card in an enabled compatible slot.
  3. Match firmware boot mode and partitioning to the supported installation configuration.
  4. Restore the supported Secure Boot configuration and trusted boot keys.

Explanation

Correct Answer

A:

TPM support relies on firmware/hardware configuration, not on a network adapter. In this situation—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled—the right response is “Enable the supported firmware TPM or compatible discrete TPM configuration.”. A confirming result would be “The operating system detects a ready TPM and measured-boot features can initialize.”.

Incorrect Answers

B:

Disabled firmware expansion paths can prevent device discovery despite correct seating. That does not directly address the condition described—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled. “Enable the supported firmware TPM or compatible discrete TPM configuration.” is the appropriate response because tPM support relies on firmware/hardware configuration, not on a network adapter.

C:

UEFI and legacy BIOS boot paths have different requirements. That does not directly address the condition described—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled. “Enable the supported firmware TPM or compatible discrete TPM configuration.” is the appropriate response because tPM support relies on firmware/hardware configuration, not on a network adapter.

D:

Secure Boot verifies signed boot components on supported UEFI systems. That does not directly address the condition described—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled. “Enable the supported firmware TPM or compatible discrete TPM configuration.” is the appropriate response because tPM support relies on firmware/hardware configuration, not on a network adapter.

Question 814

A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled. Which observation directly verifies a successful repair?

  1. Both devices enumerate and sustain their expected negotiated PCIe links together.
  2. The operating system detects a ready TPM and measured-boot features can initialize.
  3. The operating system enumerates the expansion card and establishes a test link.
  4. Firmware identifies the new CPU and POST completes with stable temperatures.

Explanation

Correct Answer

B:

TPM support relies on firmware/hardware configuration, not on a network adapter. The outcome “The operating system detects a ready TPM and measured-boot features can initialize.” verifies the action “Enable the supported firmware TPM or compatible discrete TPM configuration.” for this situation: A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled.

Incorrect Answers

A:

Chipset and CPU lane sharing can disable or reduce PCIe connectors when another socket consumes the same resources. For the situation described—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled—this would not demonstrate the specified intervention. The relevant evidence is “The operating system detects a ready TPM and measured-boot features can initialize.”.

C:

Disabled firmware expansion paths can prevent device discovery despite correct seating. For the situation described—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled—this would not demonstrate the specified intervention. The relevant evidence is “The operating system detects a ready TPM and measured-boot features can initialize.”.

D:

CPU support can depend on BIOS microcode even with a physically matching socket. For the situation described—A Windows security policy requires firmware measured boot, but the motherboard's fTPM capability is disabled—this would not demonstrate the specified intervention. The relevant evidence is “The operating system detects a ready TPM and measured-boot features can initialize.”.

Question 815

A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage. Which change best satisfies the stated requirement?

  1. Size the supply by continuous output requirement and interpret efficiency separately.
  2. Replace the failed matching PSU without disrupting the remaining feed per vendor procedure.
  3. Connect redundant PSU feeds to appropriately independent protected power circuits.
  4. Confirm PSU input voltage auto-ranging or the correct selector setting before energizing.

Explanation

Correct Answer

A:

Efficiency ratings express conversion losses, not the computer's fixed power consumption. In this situation—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage—the right response is “Size the supply by continuous output requirement and interpret efficiency separately.”. A confirming result would be “Load testing confirms enough delivered wattage within the expected AC input draw.”.

Incorrect Answers

B:

Redundant PSU design can tolerate a single power module failure. That does not directly address the condition described—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage. “Size the supply by continuous output requirement and interpret efficiency separately.” is the appropriate response because efficiency ratings express conversion losses, not the computer's fixed power consumption.

C:

Redundant modules share a single power failure domain when both depend on one outlet. That does not directly address the condition described—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage. “Size the supply by continuous output requirement and interpret efficiency separately.” is the appropriate response because efficiency ratings express conversion losses, not the computer's fixed power consumption.

D:

Incorrect mains input settings can damage a supply. That does not directly address the condition described—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage. “Size the supply by continuous output requirement and interpret efficiency separately.” is the appropriate response because efficiency ratings express conversion losses, not the computer's fixed power consumption.

Question 816

A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage. What evidence shows that the intended requirement has been met?

  1. The PSU input specification matches the destination mains and boots safely.
  2. A controlled loss of one feed leaves the NAS online without loss of redundancy after recovery.
  3. Load testing confirms enough delivered wattage within the expected AC input draw.
  4. The rail stays within tolerance and GPU stress testing completes normally.

Explanation

Correct Answer

C:

Efficiency ratings express conversion losses, not the computer's fixed power consumption. The outcome “Load testing confirms enough delivered wattage within the expected AC input draw.” verifies the action “Size the supply by continuous output requirement and interpret efficiency separately.” for this situation: A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage.

Incorrect Answers

A:

Incorrect mains input settings can damage a supply. For the situation described—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage—this would not demonstrate the specified intervention. The relevant evidence is “Load testing confirms enough delivered wattage within the expected AC input draw.”.

B:

Redundant modules share a single power failure domain when both depend on one outlet. For the situation described—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage—this would not demonstrate the specified intervention. The relevant evidence is “Load testing confirms enough delivered wattage within the expected AC input draw.”.

D:

Voltage sag under load can destabilize components even when the PSU spins its fan. For the situation described—A 650 W PSU is labeled 80 PLUS Gold but a technician interprets the label as a guarantee of 650 W input usage—this would not demonstrate the specified intervention. The relevant evidence is “Load testing confirms enough delivered wattage within the expected AC input draw.”.

Question 817

A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector. What should the technician configure or repair to resolve this issue?

  1. Connect redundant PSU feeds to appropriately independent protected power circuits.
  2. Select a supply with the correct ATX motherboard and CPU power connectors.
  3. Specify a quality PSU with sufficient continuous output and headroom.
  4. Use the proper EPS CPU power connector from the PSU.

Explanation

Correct Answer

B:

Modern motherboards require specific ATX and EPS power harnesses. In this situation—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector—the right response is “Select a supply with the correct ATX motherboard and CPU power connectors.”. A confirming result would be “The board POSTs with approved native power leads connected.”.

Incorrect Answers

A:

Redundant modules share a single power failure domain when both depend on one outlet. That does not directly address the condition described—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector. “Select a supply with the correct ATX motherboard and CPU power connectors.” is the appropriate response because modern motherboards require specific ATX and EPS power harnesses.

C:

Insufficient PSU capacity can cause resets or shutdown under load. That does not directly address the condition described—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector. “Select a supply with the correct ATX motherboard and CPU power connectors.” is the appropriate response because modern motherboards require specific ATX and EPS power harnesses.

D:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. That does not directly address the condition described—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector. “Select a supply with the correct ATX motherboard and CPU power connectors.” is the appropriate response because modern motherboards require specific ATX and EPS power harnesses.

Question 818

A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector. How should the technician verify the corrective change?

  1. The board POSTs with approved native power leads connected.
  2. The system powers and POSTs without CPU power warnings.
  3. Each connector and voltage passes an approved safety inspection.
  4. Both power modules report healthy redundancy after replacement.

Explanation

Correct Answer

A:

Modern motherboards require specific ATX and EPS power harnesses. The outcome “The board POSTs with approved native power leads connected.” verifies the action “Select a supply with the correct ATX motherboard and CPU power connectors.” for this situation: A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector.

Incorrect Answers

B:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. For the situation described—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector—this would not demonstrate the specified intervention. The relevant evidence is “The board POSTs with approved native power leads connected.”.

C:

Modular PSU-side pinouts can differ even if device-side connectors look identical. For the situation described—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector—this would not demonstrate the specified intervention. The relevant evidence is “The board POSTs with approved native power leads connected.”.

D:

Redundant PSU design can tolerate a single power module failure. For the situation described—A PC needs a replacement PSU and the available model lacks the motherboard's required 24-pin ATX connector—this would not demonstrate the specified intervention. The relevant evidence is “The board POSTs with approved native power leads connected.”.

Question 819

A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets. Which intervention is best supported by the evidence?

  1. Use the replacement PSU's approved modular cable set only.
  2. Use the proper EPS CPU power connector from the PSU.
  3. Specify a quality PSU with sufficient continuous output and headroom.
  4. Replace the failing PSU after safe voltage/load verification.

Explanation

Correct Answer

D:

Voltage sag under load can destabilize components even when the PSU spins its fan. In this situation—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets—the right response is “Replace the failing PSU after safe voltage/load verification.”. A confirming result would be “The rail stays within tolerance and GPU stress testing completes normally.”.

Incorrect Answers

A:

Modular PSU-side pinouts can differ even if device-side connectors look identical. That does not directly address the condition described—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets. “Replace the failing PSU after safe voltage/load verification.” is the appropriate response because voltage sag under load can destabilize components even when the PSU spins its fan.

B:

EPS12V CPU and PCIe GPU power connectors are not interchangeable. That does not directly address the condition described—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets. “Replace the failing PSU after safe voltage/load verification.” is the appropriate response because voltage sag under load can destabilize components even when the PSU spins its fan.

C:

Insufficient PSU capacity can cause resets or shutdown under load. That does not directly address the condition described—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets. “Replace the failing PSU after safe voltage/load verification.” is the appropriate response because voltage sag under load can destabilize components even when the PSU spins its fan.

Question 820

A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets. Which test outcome demonstrates that the chosen action worked?

  1. The workstation remains stable during representative peak power loading.
  2. The rail stays within tolerance and GPU stress testing completes normally.
  3. Load testing confirms enough delivered wattage within the expected AC input draw.
  4. The PSU input specification matches the destination mains and boots safely.

Explanation

Correct Answer

B:

Voltage sag under load can destabilize components even when the PSU spins its fan. The outcome “The rail stays within tolerance and GPU stress testing completes normally.” verifies the action “Replace the failing PSU after safe voltage/load verification.” for this situation: A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets.

Incorrect Answers

A:

Insufficient PSU capacity can cause resets or shutdown under load. For the situation described—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets—this would not demonstrate the specified intervention. The relevant evidence is “The rail stays within tolerance and GPU stress testing completes normally.”.

C:

Efficiency ratings express conversion losses, not the computer's fixed power consumption. For the situation described—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets—this would not demonstrate the specified intervention. The relevant evidence is “The rail stays within tolerance and GPU stress testing completes normally.”.

D:

Incorrect mains input settings can damage a supply. For the situation described—A desktop supply produces an unstable 12 V rail under load and software logs unexplained GPU resets—this would not demonstrate the specified intervention. The relevant evidence is “The rail stays within tolerance and GPU stress testing completes normally.”.