McAfee-Secured Website

Exam Bundle

Exam Code: 220-1201

Exam Name CompTIA A+ Certification Exam: Core 1

Certification Provider: CompTIA

Corresponding Certification: CompTIA A+

CompTIA 220-1201 Bundle $44.99

100% CompTIA 220-1201 Guaranteed Success With Testking Training Materials

Get Real 220-1201 Exam Questions & Expert Verified Answers as Experienced on the Real Exam!

  • Questions & Answers

    220-1201 Questions & Answers

    527 Questions & Answers

    The ultimate exam preparation tool, Questions & Answers mirrors the actual 220-1201 exam while allowing you to hone and measure every aspect of your test-taking ability.

  • 220-1201 Video Course

    220-1201 Video Course

    106 Video Lectures

    220-1201 Video Course is developed by CompTIA Professionals to help you pass the 220-1201 exam.

    Description

    This course will improve your knowledge and skills required to pass CompTIA A+ Certification Exam: Core 1 exam.
  • Study Guide

    220-1201 Study Guide

    2615 PDF Pages

    Developed by industry experts, this 2615-page guide spells out in painstaking detail all of the information you need to ace 220-1201 exam.

CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Total Cost: $194.97
Bundle Price: $149.98

Purchase Individually

  • Questions & Answers

    Questions & Answers

    527 Questions

    $124.99
  • 220-1201 Video Course

    Video Course

    106 Video Lectures

    $39.99
  • Study Guide

    Study Guide

    2615 PDF Pages

    $29.99

CompTIA 220-1201 Practice Test 3

Question 20

An employee's laptop intermittently loses Bluetooth and Wi-Fi after the wireless card was upgraded. After the appropriate change, which observation BEST verifies the intended result?

  1. Signal strength remains stable while the lid moves through its full range.
  2. The internal image remains stable at multiple lid angles.
  3. The integrated camera is detected and produces a clear test image.
  4. Both radios stay connected after a reboot and movement test.

Explanation

Correct Answer

D:

Shared module replacement and misattached antenna leads explain simultaneous wireless instability. The outcome “Both radios stay connected after a reboot and movement test.” verifies the action “Check the replacement WLAN card's antenna terminal connections and compatibility.” for this situation: An employee's laptop intermittently loses Bluetooth and Wi-Fi after the wireless card was upgraded.

Incorrect Answers

A:

A pinched antenna lead can change radio reception as the lid flexes. For the situation described—An employee's laptop intermittently loses Bluetooth and Wi-Fi after the wireless card was upgraded—this would not demonstrate the specified intervention. The relevant evidence is “Both radios stay connected after a reboot and movement test.”.

B:

An angle-sensitive failure with working external video suggests a flexing internal display cable. For the situation described—An employee's laptop intermittently loses Bluetooth and Wi-Fi after the wireless card was upgraded—this would not demonstrate the specified intervention. The relevant evidence is “Both radios stay connected after a reboot and movement test.”.

C:

The timing implicates the ribbon connection rather than the operating system's external camera support. For the situation described—An employee's laptop intermittently loses Bluetooth and Wi-Fi after the wireless card was upgraded—this would not demonstrate the specified intervention. The relevant evidence is “Both radios stay connected after a reboot and movement test.”.

Question 21

A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots. Which action is MOST appropriate for this situation?

  1. Install manufacturer-supported SO-DIMMs matching the platform generation.
  2. Inspect and replace the damaged internal display cable through the hinge.
  3. Inspect and replace the liquid-damaged speaker assembly after safe service.
  4. Replace the damaged screen assembly according to the service guide.

Explanation

Correct Answer

A:

Notebook slots use SO-DIMM form factors and reject incompatible memory generations. In this situation—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots—the right response is “Install manufacturer-supported SO-DIMMs matching the platform generation.”. A confirming result would be “Firmware reports the intended total capacity and memory diagnostics pass.”.

Incorrect Answers

B:

An angle-sensitive failure with working external video suggests a flexing internal display cable. That does not directly address the condition described—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots. “Install manufacturer-supported SO-DIMMs matching the platform generation.” is the appropriate response because notebook slots use SO-DIMM form factors and reject incompatible memory generations.

C:

Good wired audio localizes the defect to the internal speaker path. That does not directly address the condition described—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots. “Install manufacturer-supported SO-DIMMs matching the platform generation.” is the appropriate response because notebook slots use SO-DIMM form factors and reject incompatible memory generations.

D:

Management visibility and vibration indicate the device boots but its display path is damaged. That does not directly address the condition described—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots. “Install manufacturer-supported SO-DIMMs matching the platform generation.” is the appropriate response because notebook slots use SO-DIMM form factors and reject incompatible memory generations.

Question 22

A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots. After the appropriate change, which observation BEST verifies the intended result?

  1. Firmware reports the intended total capacity and memory diagnostics pass.
  2. Signal strength remains stable while the lid moves through its full range.
  3. The system runs on battery and reports a normal charge/discharge cycle.
  4. Battery is isolated and the bulging cell is documented for safe replacement.

Explanation

Correct Answer

A:

Notebook slots use SO-DIMM form factors and reject incompatible memory generations. The outcome “Firmware reports the intended total capacity and memory diagnostics pass.” verifies the action “Install manufacturer-supported SO-DIMMs matching the platform generation.” for this situation: A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots.

Incorrect Answers

B:

A pinched antenna lead can change radio reception as the lid flexes. For the situation described—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports the intended total capacity and memory diagnostics pass.”.

C:

External power bypasses a battery that no longer stores usable energy. For the situation described—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports the intended total capacity and memory diagnostics pass.”.

D:

A swollen lithium cell is a physical fire hazard; power cycling cannot repair it. For the situation described—A mobile workstation needs a memory upgrade and has two accessible small-form-factor RAM slots—this would not demonstrate the specified intervention. The relevant evidence is “Firmware reports the intended total capacity and memory diagnostics pass.”.

Question 23

A convertible notebook's fingerprint reader stops responding after a palm-rest replacement. Which action is MOST appropriate for this situation?

  1. Replace the failed internal battery with the approved pack.
  2. Disconnect power, stop use and arrange trained battery service.
  3. Replace the laptop keyboard with the compatible layout assembly.
  4. Check the biometric sensor cable and approved replacement part.

Explanation

Correct Answer

D:

The failed biometric function follows the palm-rest assembly service, pointing to its sensor path. In this situation—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement—the right response is “Check the biometric sensor cable and approved replacement part.”. A confirming result would be “Fingerprint enrollment and unlock succeed with the integrated reader.”.

Incorrect Answers

A:

External power bypasses a battery that no longer stores usable energy. That does not directly address the condition described—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement. “Check the biometric sensor cable and approved replacement part.” is the appropriate response because the failed biometric function follows the palm-rest assembly service, pointing to its sensor path.

B:

A swollen lithium cell is a physical fire hazard; power cycling cannot repair it. That does not directly address the condition described—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement. “Check the biometric sensor cable and approved replacement part.” is the appropriate response because the failed biometric function follows the palm-rest assembly service, pointing to its sensor path.

C:

External input success isolates the integrated keyboard hardware. That does not directly address the condition described—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement. “Check the biometric sensor cable and approved replacement part.” is the appropriate response because the failed biometric function follows the palm-rest assembly service, pointing to its sensor path.

Question 24

A convertible notebook's fingerprint reader stops responding after a palm-rest replacement. After the appropriate change, which observation BEST verifies the intended result?

  1. The integrated camera is detected and produces a clear test image.
  2. The system runs on battery and reports a normal charge/discharge cycle.
  3. All repaired keys register correctly in a keyboard diagnostic.
  4. Fingerprint enrollment and unlock succeed with the integrated reader.

Explanation

Correct Answer

D:

The failed biometric function follows the palm-rest assembly service, pointing to its sensor path. The outcome “Fingerprint enrollment and unlock succeed with the integrated reader.” verifies the action “Check the biometric sensor cable and approved replacement part.” for this situation: A convertible notebook's fingerprint reader stops responding after a palm-rest replacement.

Incorrect Answers

A:

The timing implicates the ribbon connection rather than the operating system's external camera support. For the situation described—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement—this would not demonstrate the specified intervention. The relevant evidence is “Fingerprint enrollment and unlock succeed with the integrated reader.”.

B:

External power bypasses a battery that no longer stores usable energy. For the situation described—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement—this would not demonstrate the specified intervention. The relevant evidence is “Fingerprint enrollment and unlock succeed with the integrated reader.”.

C:

External input success isolates the integrated keyboard hardware. For the situation described—A convertible notebook's fingerprint reader stops responding after a palm-rest replacement—this would not demonstrate the specified intervention. The relevant evidence is “Fingerprint enrollment and unlock succeed with the integrated reader.”.

Question 25

A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable. Which action is MOST appropriate for this situation?

  1. Inspect and replace the damaged internal display cable through the hinge.
  2. Inspect the antenna lead routing through the display hinge.
  3. Inspect and replace the damaged internal microphone module.
  4. Inspect and replace the liquid-damaged speaker assembly after safe service.

Explanation

Correct Answer

A:

An angle-sensitive failure with working external video suggests a flexing internal display cable. In this situation—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable—the right response is “Inspect and replace the damaged internal display cable through the hinge.”. A confirming result would be “The internal image remains stable at multiple lid angles.”.

Incorrect Answers

B:

A pinched antenna lead can change radio reception as the lid flexes. That does not directly address the condition described—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable. “Inspect and replace the damaged internal display cable through the hinge.” is the appropriate response because an angle-sensitive failure with working external video suggests a flexing internal display cable.

C:

A good headset proves the recording application works, isolating the built-in microphone path. That does not directly address the condition described—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable. “Inspect and replace the damaged internal display cable through the hinge.” is the appropriate response because an angle-sensitive failure with working external video suggests a flexing internal display cable.

D:

Good wired audio localizes the defect to the internal speaker path. That does not directly address the condition described—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable. “Inspect and replace the damaged internal display cable through the hinge.” is the appropriate response because an angle-sensitive failure with working external video suggests a flexing internal display cable.

Question 26

A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable. After the appropriate change, which observation BEST verifies the intended result?

  1. The internal image remains stable at multiple lid angles.
  2. Signal strength remains stable while the lid moves through its full range.
  3. The new panel displays the startup image and responds evenly.
  4. The integrated camera is detected and produces a clear test image.

Explanation

Correct Answer

A:

An angle-sensitive failure with working external video suggests a flexing internal display cable. The outcome “The internal image remains stable at multiple lid angles.” verifies the action “Inspect and replace the damaged internal display cable through the hinge.” for this situation: A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable.

Incorrect Answers

B:

A pinched antenna lead can change radio reception as the lid flexes. For the situation described—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable—this would not demonstrate the specified intervention. The relevant evidence is “The internal image remains stable at multiple lid angles.”.

C:

Management visibility and vibration indicate the device boots but its display path is damaged. For the situation described—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable—this would not demonstrate the specified intervention. The relevant evidence is “The internal image remains stable at multiple lid angles.”.

D:

The timing implicates the ribbon connection rather than the operating system's external camera support. For the situation described—A laptop's display goes black when its hinge passes halfway, but an external monitor stays stable—this would not demonstrate the specified intervention. The relevant evidence is “The internal image remains stable at multiple lid angles.”.

Question 27

A tablet's USB-C port is physically loose and requires pressure to keep a charger attached. Which action is MOST appropriate for this situation?

  1. Replace the damaged screen assembly according to the service guide.
  2. Inspect and replace the damaged internal microphone module.
  3. Replace the damaged port or serviceable daughterboard, not the charger software.
  4. Inspect and replace the damaged internal display cable through the hinge.

Explanation

Correct Answer

C:

Mechanical looseness at the receptacle prevents reliable contact. In this situation—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached—the right response is “Replace the damaged port or serviceable daughterboard, not the charger software.”. A confirming result would be “A compatible cable seats firmly and charging remains stable without pressure.”.

Incorrect Answers

A:

Management visibility and vibration indicate the device boots but its display path is damaged. That does not directly address the condition described—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached. “Replace the damaged port or serviceable daughterboard, not the charger software.” is the appropriate response because mechanical looseness at the receptacle prevents reliable contact.

B:

A good headset proves the recording application works, isolating the built-in microphone path. That does not directly address the condition described—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached. “Replace the damaged port or serviceable daughterboard, not the charger software.” is the appropriate response because mechanical looseness at the receptacle prevents reliable contact.

D:

An angle-sensitive failure with working external video suggests a flexing internal display cable. That does not directly address the condition described—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached. “Replace the damaged port or serviceable daughterboard, not the charger software.” is the appropriate response because mechanical looseness at the receptacle prevents reliable contact.

Question 28

A tablet's USB-C port is physically loose and requires pressure to keep a charger attached. After the appropriate change, which observation BEST verifies the intended result?

  1. A compatible cable seats firmly and charging remains stable without pressure.
  2. Signal strength remains stable while the lid moves through its full range.
  3. The internal image remains stable at multiple lid angles.
  4. The new panel displays the startup image and responds evenly.

Explanation

Correct Answer

A:

Mechanical looseness at the receptacle prevents reliable contact. The outcome “A compatible cable seats firmly and charging remains stable without pressure.” verifies the action “Replace the damaged port or serviceable daughterboard, not the charger software.” for this situation: A tablet's USB-C port is physically loose and requires pressure to keep a charger attached.

Incorrect Answers

B:

A pinched antenna lead can change radio reception as the lid flexes. For the situation described—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached—this would not demonstrate the specified intervention. The relevant evidence is “A compatible cable seats firmly and charging remains stable without pressure.”.

C:

An angle-sensitive failure with working external video suggests a flexing internal display cable. For the situation described—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached—this would not demonstrate the specified intervention. The relevant evidence is “A compatible cable seats firmly and charging remains stable without pressure.”.

D:

Management visibility and vibration indicate the device boots but its display path is damaged. For the situation described—A tablet's USB-C port is physically loose and requires pressure to keep a charger attached—this would not demonstrate the specified intervention. The relevant evidence is “A compatible cable seats firmly and charging remains stable without pressure.”.

Question 29

A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear. Which action is MOST appropriate for this situation?

  1. Replace the damaged screen assembly according to the service guide.
  2. Inspect and replace the damaged internal display cable through the hinge.
  3. Inspect and replace the liquid-damaged speaker assembly after safe service.
  4. Inspect and replace the damaged internal microphone module.

Explanation

Correct Answer

C:

Good wired audio localizes the defect to the internal speaker path. In this situation—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear—the right response is “Inspect and replace the liquid-damaged speaker assembly after safe service.”. A confirming result would be “Internal speakers reproduce a clean stereo test without crackle.”.

Incorrect Answers

A:

Management visibility and vibration indicate the device boots but its display path is damaged. That does not directly address the condition described—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear. “Inspect and replace the liquid-damaged speaker assembly after safe service.” is the appropriate response because good wired audio localizes the defect to the internal speaker path.

B:

An angle-sensitive failure with working external video suggests a flexing internal display cable. That does not directly address the condition described—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear. “Inspect and replace the liquid-damaged speaker assembly after safe service.” is the appropriate response because good wired audio localizes the defect to the internal speaker path.

D:

A good headset proves the recording application works, isolating the built-in microphone path. That does not directly address the condition described—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear. “Inspect and replace the liquid-damaged speaker assembly after safe service.” is the appropriate response because good wired audio localizes the defect to the internal speaker path.

Question 30

A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear. After the appropriate change, which observation BEST verifies the intended result?

  1. Internal speakers reproduce a clean stereo test without crackle.
  2. The internal image remains stable at multiple lid angles.
  3. Repeated cold boots detect the drive without intermittent disconnects.
  4. Both radios stay connected after a reboot and movement test.

Explanation

Correct Answer

A:

Good wired audio localizes the defect to the internal speaker path. The outcome “Internal speakers reproduce a clean stereo test without crackle.” verifies the action “Inspect and replace the liquid-damaged speaker assembly after safe service.” for this situation: A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear.

Incorrect Answers

B:

An angle-sensitive failure with working external video suggests a flexing internal display cable. For the situation described—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear—this would not demonstrate the specified intervention. The relevant evidence is “Internal speakers reproduce a clean stereo test without crackle.”.

C:

Shock can loosen storage connections without making the SSD itself unhealthy. For the situation described—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear—this would not demonstrate the specified intervention. The relevant evidence is “Internal speakers reproduce a clean stereo test without crackle.”.

D:

Shared module replacement and misattached antenna leads explain simultaneous wireless instability. For the situation described—A laptop's internal speakers crackle after liquid was spilled on the speaker grille, but wired headphones sound clear—this would not demonstrate the specified intervention. The relevant evidence is “Internal speakers reproduce a clean stereo test without crackle.”.